{"id":{"repo_id":"ksu","oai_identifier":"oai:krex.k-state.edu:2097/14643"},"canonical_url":"https://search.ndltd.org/etd/ksu/oai:krex.k-state.edu:2097/14643","repository":{"repo_id":"ksu","name":"Kansas State University","base_url":"https://krex.k-state.edu/server/oai/request"},"display":{"title":"High impedance fault location identification using Bayesian analysis in a shipboard power system","abstract":"In a shipboard power system (SPS) there are many possible locations for faults along power lines. It is important to identify the location and isolate these faults in order to protect the equipment and loads. The shipboard systems represented in this research are based on an all-electric ship that is presented by Corzine and a simplified version of the same ship. This research considers faults at the ends on the lines. Sensors collect data in order to determine where the fault has occurred. The fault location identification algorithm being presented uses data collected from simulations of different switch configurations and different loads. After the data is collected, Bayesian techniques are used to determine where the fault is located. An online training technique is presented to adjust to changes in loads over time to increase the accuracy of the algorithm.","abstract_html":"In a shipboard power system (SPS) there are many possible locations for faults along power lines. It is important to identify the location and isolate these faults in order to protect the equipment and loads. The shipboard systems represented in this research are based on an all-electric ship that is presented by Corzine and a simplified version of the same ship. This research considers faults at the ends on the lines. Sensors collect data in order to determine where the fault has occurred. The fault location identification algorithm being presented uses data collected from simulations of different switch configurations and different loads. After the data is collected, Bayesian techniques are used to determine where the fault is located. An online training technique is presented to adjust to changes in loads over time to increase the accuracy of the algorithm.","abstract_has_math":false,"creators":["Dieker, Joseph"],"institution":"Kansas State University","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Department of Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Sanjoy Das","Noel N. Schulz"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-09-06","date_published":"2012-09-06","updated_at":"2026-11-26T03:05:54Z","subjects":["Shipboard","Power","Fault","Location","Bayesian"],"languages":["en_US"],"rights":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2097/14643","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2097/14643","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aksu%3Aoai%3Akrex.k-state.edu%3A2097%2F14643","prefix":"oai_dc"},"source_record":{"url":"https://krex.k-state.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Akrex.k-state.edu%3A2097%2F14643","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Department of Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Dieker, Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-09-06T14:28:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-09-06T14:28:30Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-09-06"]},{"key":"dc:date.published","label":"Dc Date Published","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Kansas State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_date","label":"Thesis Degree Date","values":["August"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Shipboard","Power","Fault","Location","Bayesian"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Electrical Engineering (0544)","Energy (0791)","Engineering (0537)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/2097/14643"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In a shipboard power system (SPS) there are many possible locations for faults along power lines. It is important to identify the location and isolate these faults in order to protect the equipment and loads. The shipboard systems represented in this research are based on an all-electric ship that is presented by Corzine and a simplified version of the same ship. This research considers faults at the ends on the lines. Sensors collect data in order to determine where the fault has occurred. The fault location identification algorithm being presented uses data collected from simulations of different switch configurations and different loads. After the data is collected, Bayesian techniques are used to determine where the fault is located. An online training technique is presented to adjust to changes in loads over time to increase the accuracy of the algorithm."]},{"key":"dc:description.advisor","label":"Dc Description Advisor","values":["Sanjoy Das","Noel N. Schulz"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["United States Office of Naval Research through grant N00014-10-1-0431 under the DEPSCoR program."]},{"key":"dc:title","label":"Title","values":["High impedance fault location identification using Bayesian analysis in a shipboard power system"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.department":["Department of Electrical and Computer Engineering"],"dc:creator":["Dieker, Joseph"],"dc:date.accessioned":["2012-09-06T14:28:30Z"],"dc:date.available":["2012-09-06T14:28:30Z"],"dc:date.issued":["2012-09-06"],"dc:date.published":["2012"],"dc:description.abstract":["In a shipboard power system (SPS) there are many possible locations for faults along power lines. It is important to identify the location and isolate these faults in order to protect the equipment and loads. The shipboard systems represented in this research are based on an all-electric ship that is presented by Corzine and a simplified version of the same ship. This research considers faults at the ends on the lines. Sensors collect data in order to determine where the fault has occurred. The fault location identification algorithm being presented uses data collected from simulations of different switch configurations and different loads. After the data is collected, Bayesian techniques are used to determine where the fault is located. An online training technique is presented to adjust to changes in loads over time to increase the accuracy of the algorithm."],"dc:description.advisor":["Sanjoy Das","Noel N. Schulz"],"dc:description.degree":["Master of Science"],"dc:description.sponsorship":["United States Office of Naval Research through grant N00014-10-1-0431 under the DEPSCoR program."],"dc:identifier.uri":["http://hdl.handle.net/2097/14643"],"dc:language.iso":["en_US"],"dc:publisher":["Kansas State University"],"dc:rights":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Shipboard","Power","Fault","Location","Bayesian"],"dc:subject.proquest":["Electrical Engineering (0544)","Energy (0791)","Engineering (0537)"],"dc:title":["High impedance fault location identification using Bayesian analysis in a shipboard power system"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_date":["August"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-26T03:05:54Z"}