{"id":{"repo_id":"ksu","oai_identifier":"oai:krex.k-state.edu:2097/47019"},"canonical_url":"https://search.ndltd.org/etd/ksu/oai:krex.k-state.edu:2097/47019","repository":{"repo_id":"ksu","name":"Kansas State University","base_url":"https://krex.k-state.edu/server/oai/request"},"display":{"title":"Development of a field water/cement ratio test using time domain reflectometry","abstract":"A reliable and nondestructive method is needed to determine the water-to-cement or water-to-cementitious material ratio (w/cm) of fresh concrete for performance-based quality assurance. This study developed and validated a Time Domain Reflectometry (TDR) based method to quantify the real-time w/cm ratio of fresh concrete. Forty-eight concrete mixtures with varying w/cm ratios, air contents, and cementitious binder types (cement-only, fly ash, and slag) were tested, and TDR measurements were synchronized with conventional tests to establish a calibrated model between the apparent dielectric constant (K_a) and volumetric water content ([Theta]_v). Data were analyzed using the statistical software R, employing group standardization, ordinary least-squares regression, and the Simulation–Extrapolation (SIMEX) method to correct for measurement-error bias. Four models developed for different cementitious binder systems showed strong consistency between measured and predicted results, confirming the reliability of the proposed calibration framework. However, as an empirical model, its applicability may be limited to the specific material range for which it was tested. Future studies should incorporate additional laboratory and field experiments, as well as explore physics-based dielectric modeling, to enhance prediction accuracy and generalization.","abstract_html":"A reliable and nondestructive method is needed to determine the water-to-cement or water-to-cementitious material ratio (w/cm) of fresh concrete for performance-based quality assurance. This study developed and validated a Time Domain Reflectometry (TDR) based method to quantify the real-time w/cm ratio of fresh concrete. Forty-eight concrete mixtures with varying w/cm ratios, air contents, and cementitious binder types (cement-only, fly ash, and slag) were tested, and TDR measurements were synchronized with conventional tests to establish a calibrated model between the apparent dielectric constant (K_a) and volumetric water content ([Theta]_v). Data were analyzed using the statistical software R, employing group standardization, ordinary least-squares regression, and the Simulation–Extrapolation (SIMEX) method to correct for measurement-error bias. Four models developed for different cementitious binder systems showed strong consistency between measured and predicted results, confirming the reliability of the proposed calibration framework. However, as an empirical model, its applicability may be limited to the specific material range for which it was tested. Future studies should incorporate additional laboratory and field experiments, as well as explore physics-based dielectric modeling, to enhance prediction accuracy and generalization.","abstract_has_math":false,"creators":["Yu, Binxiang"],"institution":null,"degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Department of Civil Engineering","school":null,"contributors":[],"advisors":["Mustaque A. Hossain","Juan Du"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-26T03:08:41Z","subjects":["Time domain reflectometry","Water–cement ratio","Fresh concrete"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2097/47019","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2097/47019","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2026-02-01","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aksu%3Aoai%3Akrex.k-state.edu%3A2097%2F47019","prefix":"oai_dc"},"source_record":{"url":"https://krex.k-state.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Akrex.k-state.edu%3A2097%2F47019","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Department of Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Yu, Binxiang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-11-18T20:08:51Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2026-02-01"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_date","label":"Thesis Degree Date","values":["December"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Time domain reflectometry","Water–cement ratio","Fresh concrete"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2097/47019"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A reliable and nondestructive method is needed to determine the water-to-cement or water-to-cementitious material ratio (w/cm) of fresh concrete for performance-based quality assurance. This study developed and validated a Time Domain Reflectometry (TDR) based method to quantify the real-time w/cm ratio of fresh concrete. Forty-eight concrete mixtures with varying w/cm ratios, air contents, and cementitious binder types (cement-only, fly ash, and slag) were tested, and TDR measurements were synchronized with conventional tests to establish a calibrated model between the apparent dielectric constant (K_a) and volumetric water content ([Theta]_v). Data were analyzed using the statistical software R, employing group standardization, ordinary least-squares regression, and the Simulation–Extrapolation (SIMEX) method to correct for measurement-error bias. Four models developed for different cementitious binder systems showed strong consistency between measured and predicted results, confirming the reliability of the proposed calibration framework. However, as an empirical model, its applicability may be limited to the specific material range for which it was tested. Future studies should incorporate additional laboratory and field experiments, as well as explore physics-based dielectric modeling, to enhance prediction accuracy and generalization."]},{"key":"dc:description.advisor","label":"Dc Description Advisor","values":["Mustaque A. Hossain","Juan Du"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Kansas Department of Transportation"]},{"key":"dc:title","label":"Title","values":["Development of a field water/cement ratio test using time domain reflectometry"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.department":["Department of Civil Engineering"],"dc:creator":["Yu, Binxiang"],"dc:date.accessioned":["2025-11-18T20:08:51Z"],"dc:date.embargo":["2026-02-01"],"dc:date.issued":["2025"],"dc:description.abstract":["A reliable and nondestructive method is needed to determine the water-to-cement or water-to-cementitious material ratio (w/cm) of fresh concrete for performance-based quality assurance. This study developed and validated a Time Domain Reflectometry (TDR) based method to quantify the real-time w/cm ratio of fresh concrete. Forty-eight concrete mixtures with varying w/cm ratios, air contents, and cementitious binder types (cement-only, fly ash, and slag) were tested, and TDR measurements were synchronized with conventional tests to establish a calibrated model between the apparent dielectric constant (K_a) and volumetric water content ([Theta]_v). Data were analyzed using the statistical software R, employing group standardization, ordinary least-squares regression, and the Simulation–Extrapolation (SIMEX) method to correct for measurement-error bias. Four models developed for different cementitious binder systems showed strong consistency between measured and predicted results, confirming the reliability of the proposed calibration framework. However, as an empirical model, its applicability may be limited to the specific material range for which it was tested. Future studies should incorporate additional laboratory and field experiments, as well as explore physics-based dielectric modeling, to enhance prediction accuracy and generalization."],"dc:description.advisor":["Mustaque A. Hossain","Juan Du"],"dc:description.degree":["Master of Science"],"dc:description.sponsorship":["Kansas Department of Transportation"],"dc:identifier.uri":["https://hdl.handle.net/2097/47019"],"dc:language.iso":["en_US"],"dc:subject":["Time domain reflectometry","Water–cement ratio","Fresh concrete"],"dc:title":["Development of a field water/cement ratio test using time domain reflectometry"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_date":["December"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-26T03:08:41Z"}