{"id":{"repo_id":"ksu","oai_identifier":"oai:krex.k-state.edu:2097/890"},"canonical_url":"https://search.ndltd.org/etd/ksu/oai:krex.k-state.edu:2097/890","repository":{"repo_id":"ksu","name":"Kansas State University","base_url":"https://krex.k-state.edu/server/oai/request"},"display":{"title":"Acoustic emission monitoring of fiber reinforced bridge panels","abstract":"Two fiber reinforced polymer (FRP) bridge deck specimens were analyzed by means of acoustic emission (AE) monitoring during a series of loading cycles performed at various locations on the composite sandwich panels' surfaces. These panels were subjected to loads that were intended to test their structural response and characteristics without exposing them to a failure scenario. This allowed the sensors to record multiple data sets without fear of having to be placed on multiple panels that could have various characteristics that alter the signals recorded. The objective throughout the analysis ias to determine how the acoustic signals respond to loading cycles and various events can affect the acoustical data. In the process of performing this examination several steps were taken including threshold application, data collection, and sensor location analysis. The thresholds are important for lowering the size of the files containing the data, while keeping important information that could determine structurally significant information. Equally important is figuring out where and how the sensors should be placed on the panels in the first place in relation to other sensors, panel features and supporting beams. The data was subjected to analysis involving the response to applied loads, joint effects and failure analysis. Using previously developed techniques the information gathered was also analyzed in terms of what type of failure could be occurring within the structure itself. This somewhat aided in the analysis after an unplanned failure event occurred to determine what cause or causes might have lead to the occurrence. The basic analyses were separated into four sets, starting with the basic analysis to determine basic correlations to the loads applied. This was followed by joint and sensor location analyses, both of which took place using a two panel setup. The last set was created upon matrix failure of the panel and the subsequent investigation.","abstract_html":"Two fiber reinforced polymer (FRP) bridge deck specimens were analyzed by means of acoustic emission (AE) monitoring during a series of loading cycles performed at various locations on the composite sandwich panels&#x27; surfaces. These panels were subjected to loads that were intended to test their structural response and characteristics without exposing them to a failure scenario. This allowed the sensors to record multiple data sets without fear of having to be placed on multiple panels that could have various characteristics that alter the signals recorded. The objective throughout the analysis ias to determine how the acoustic signals respond to loading cycles and various events can affect the acoustical data. In the process of performing this examination several steps were taken including threshold application, data collection, and sensor location analysis. The thresholds are important for lowering the size of the files containing the data, while keeping important information that could determine structurally significant information. Equally important is figuring out where and how the sensors should be placed on the panels in the first place in relation to other sensors, panel features and supporting beams. The data was subjected to analysis involving the response to applied loads, joint effects and failure analysis. Using previously developed techniques the information gathered was also analyzed in terms of what type of failure could be occurring within the structure itself. This somewhat aided in the analysis after an unplanned failure event occurred to determine what cause or causes might have lead to the occurrence. The basic analyses were separated into four sets, starting with the basic analysis to determine basic correlations to the loads applied. This was followed by joint and sensor location analyses, both of which took place using a two panel setup. The last set was created upon matrix failure of the panel and the subsequent investigation.","abstract_has_math":false,"creators":["Flannigan, James Christopher"],"institution":"Kansas State University","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Department of Mechanical and Nuclear Engineering","school":null,"contributors":[],"advisors":["Youqi Wang"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-07-24T22:11:20Z","date_published":"2008-07-24T22:11:20Z","updated_at":"2026-11-26T03:10:01Z","subjects":["Fiber Reinforced Polymer","Acoustic Emission","Bridge Deck","Data Analysis"],"languages":["en_US"],"rights":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2097/890","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2097/890","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aksu%3Aoai%3Akrex.k-state.edu%3A2097%2F890","prefix":"oai_dc"},"source_record":{"url":"https://krex.k-state.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Akrex.k-state.edu%3A2097%2F890","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Department of Mechanical and Nuclear Engineering"]},{"key":"dc:creator","label":"Author","values":["Flannigan, James Christopher"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-07-24T22:11:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-07-24T22:11:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-07-24T22:11:20Z"]},{"key":"dc:date.published","label":"Dc Date Published","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Kansas State University"]},{"key":"dc:type","label":"Dc Type","values":["Report"]},{"key":"thesis:degree_date","label":"Thesis Degree Date","values":["August"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fiber Reinforced Polymer","Acoustic Emission","Bridge Deck","Data Analysis"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Civil (0543)","Engineering, Mechanical (0548)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/2097/890"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Two fiber reinforced polymer (FRP) bridge deck specimens were analyzed by means of acoustic emission (AE) monitoring during a series of loading cycles performed at various locations on the composite sandwich panels' surfaces. These panels were subjected to loads that were intended to test their structural response and characteristics without exposing them to a failure scenario. This allowed the sensors to record multiple data sets without fear of having to be placed on multiple panels that could have various characteristics that alter the signals recorded. The objective throughout the analysis ias to determine how the acoustic signals respond to loading cycles and various events can affect the acoustical data. In the process of performing this examination several steps were taken including threshold application, data collection, and sensor location analysis. The thresholds are important for lowering the size of the files containing the data, while keeping important information that could determine structurally significant information. Equally important is figuring out where and how the sensors should be placed on the panels in the first place in relation to other sensors, panel features and supporting beams. The data was subjected to analysis involving the response to applied loads, joint effects and failure analysis. Using previously developed techniques the information gathered was also analyzed in terms of what type of failure could be occurring within the structure itself. This somewhat aided in the analysis after an unplanned failure event occurred to determine what cause or causes might have lead to the occurrence. The basic analyses were separated into four sets, starting with the basic analysis to determine basic correlations to the loads applied. This was followed by joint and sensor location analyses, both of which took place using a two panel setup. The last set was created upon matrix failure of the panel and the subsequent investigation."]},{"key":"dc:description.advisor","label":"Dc Description Advisor","values":["Youqi Wang"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Kansas Department of Transportation"]},{"key":"dc:title","label":"Title","values":["Acoustic emission monitoring of fiber reinforced bridge panels"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.department":["Department of Mechanical and Nuclear Engineering"],"dc:creator":["Flannigan, James Christopher"],"dc:date.accessioned":["2008-07-24T22:11:20Z"],"dc:date.available":["2008-07-24T22:11:20Z"],"dc:date.issued":["2008-07-24T22:11:20Z"],"dc:date.published":["2008"],"dc:description.abstract":["Two fiber reinforced polymer (FRP) bridge deck specimens were analyzed by means of acoustic emission (AE) monitoring during a series of loading cycles performed at various locations on the composite sandwich panels' surfaces. These panels were subjected to loads that were intended to test their structural response and characteristics without exposing them to a failure scenario. This allowed the sensors to record multiple data sets without fear of having to be placed on multiple panels that could have various characteristics that alter the signals recorded. The objective throughout the analysis ias to determine how the acoustic signals respond to loading cycles and various events can affect the acoustical data. In the process of performing this examination several steps were taken including threshold application, data collection, and sensor location analysis. The thresholds are important for lowering the size of the files containing the data, while keeping important information that could determine structurally significant information. Equally important is figuring out where and how the sensors should be placed on the panels in the first place in relation to other sensors, panel features and supporting beams. The data was subjected to analysis involving the response to applied loads, joint effects and failure analysis. Using previously developed techniques the information gathered was also analyzed in terms of what type of failure could be occurring within the structure itself. This somewhat aided in the analysis after an unplanned failure event occurred to determine what cause or causes might have lead to the occurrence. The basic analyses were separated into four sets, starting with the basic analysis to determine basic correlations to the loads applied. This was followed by joint and sensor location analyses, both of which took place using a two panel setup. The last set was created upon matrix failure of the panel and the subsequent investigation."],"dc:description.advisor":["Youqi Wang"],"dc:description.degree":["Master of Science"],"dc:description.sponsorship":["Kansas Department of Transportation"],"dc:identifier.uri":["http://hdl.handle.net/2097/890"],"dc:language.iso":["en_US"],"dc:publisher":["Kansas State University"],"dc:rights":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Fiber Reinforced Polymer","Acoustic Emission","Bridge Deck","Data Analysis"],"dc:subject.proquest":["Engineering, Civil (0543)","Engineering, Mechanical (0548)"],"dc:title":["Acoustic emission monitoring of fiber reinforced bridge panels"],"dc:type":["Report"],"others:access_status":["open.access"],"thesis:degree_date":["August"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-26T03:10:01Z"}