{"id":{"repo_id":"ksu","oai_identifier":"oai:krex.k-state.edu:2097/894"},"canonical_url":"https://search.ndltd.org/etd/ksu/oai:krex.k-state.edu:2097/894","repository":{"repo_id":"ksu","name":"Kansas State University","base_url":"https://krex.k-state.edu/server/oai/request"},"display":{"title":"Photon signatures for standoff bomb detection","abstract":"The purpose of this research was to develop a technology to quickly identify hidden explosive materials. The developed method needs to be performed at a standoff distance of approximately two meters or more, must have high sensitivity (low false-negative rate) and good specificity (low false-positive rate), and should be able to detect a minimum amount of approximately one gallon (15 lbs) of explosive material. In an effort to meet these goals, a template-matching procedure to aid in the rapid detection of hidden improvised explosive devices was investigated. Multiple photon-scattered responses are being used as a part of a multidimensional signature-based radiation scanning (SBRS) approach in an attempt to detect chemical explosives at safe, standoff distances. The SBRS approach utilizes both neutron and photon interrogation to determine if a target contains explosive material, but the focus of this thesis is on photon interrogation. Beams of photons are used to create back-streamed responses called signatures, which are dependent on the density and the composition of the target. These signatures are compared to templates, which are collections of the same signatures if the interrogated volume contained a significant amount of explosives. The signature analysis produces a single figure-of-merit. A low figure-of-merit indicates an explosive might be present in the target. Experiments have been conducted that show an explosive surrogate (fertilizer) can be distinguished from several inert materials using these photon signatures, proving these signatures to be very useful in this particular method of chemical explosive detection.","abstract_html":"The purpose of this research was to develop a technology to quickly identify hidden explosive materials. The developed method needs to be performed at a standoff distance of approximately two meters or more, must have high sensitivity (low false-negative rate) and good specificity (low false-positive rate), and should be able to detect a minimum amount of approximately one gallon (15 lbs) of explosive material. In an effort to meet these goals, a template-matching procedure to aid in the rapid detection of hidden improvised explosive devices was investigated. Multiple photon-scattered responses are being used as a part of a multidimensional signature-based radiation scanning (SBRS) approach in an attempt to detect chemical explosives at safe, standoff distances. The SBRS approach utilizes both neutron and photon interrogation to determine if a target contains explosive material, but the focus of this thesis is on photon interrogation. Beams of photons are used to create back-streamed responses called signatures, which are dependent on the density and the composition of the target. These signatures are compared to templates, which are collections of the same signatures if the interrogated volume contained a significant amount of explosives. The signature analysis produces a single figure-of-merit. A low figure-of-merit indicates an explosive might be present in the target. Experiments have been conducted that show an explosive surrogate (fertilizer) can be distinguished from several inert materials using these photon signatures, proving these signatures to be very useful in this particular method of chemical explosive detection.","abstract_has_math":false,"creators":["Loschke, Kyle W."],"institution":"Kansas State University","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":"Department of Mechanical and Nuclear Engineering","school":null,"contributors":[],"advisors":["William L. Dunn"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-07-29T16:45:20Z","date_published":"2008-07-29T16:45:20Z","updated_at":"2026-11-26T03:08:32Z","subjects":["Improvised explosive device","Photon","Detection"],"languages":["en_US"],"rights":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2097/894","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2097/894","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aksu%3Aoai%3Akrex.k-state.edu%3A2097%2F894","prefix":"oai_dc"},"source_record":{"url":"https://krex.k-state.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Akrex.k-state.edu%3A2097%2F894","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Department of Mechanical and Nuclear Engineering"]},{"key":"dc:creator","label":"Author","values":["Loschke, Kyle W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-07-29T16:45:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-07-29T16:45:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-07-29T16:45:20Z"]},{"key":"dc:date.published","label":"Dc Date Published","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Kansas State University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_date","label":"Thesis Degree Date","values":["August"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Improvised explosive device","Photon","Detection"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Nuclear (0552)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/2097/894"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this research was to develop a technology to quickly identify hidden explosive materials. The developed method needs to be performed at a standoff distance of approximately two meters or more, must have high sensitivity (low false-negative rate) and good specificity (low false-positive rate), and should be able to detect a minimum amount of approximately one gallon (15 lbs) of explosive material. In an effort to meet these goals, a template-matching procedure to aid in the rapid detection of hidden improvised explosive devices was investigated. Multiple photon-scattered responses are being used as a part of a multidimensional signature-based radiation scanning (SBRS) approach in an attempt to detect chemical explosives at safe, standoff distances. The SBRS approach utilizes both neutron and photon interrogation to determine if a target contains explosive material, but the focus of this thesis is on photon interrogation. Beams of photons are used to create back-streamed responses called signatures, which are dependent on the density and the composition of the target. These signatures are compared to templates, which are collections of the same signatures if the interrogated volume contained a significant amount of explosives. The signature analysis produces a single figure-of-merit. A low figure-of-merit indicates an explosive might be present in the target. Experiments have been conducted that show an explosive surrogate (fertilizer) can be distinguished from several inert materials using these photon signatures, proving these signatures to be very useful in this particular method of chemical explosive detection."]},{"key":"dc:description.advisor","label":"Dc Description Advisor","values":["William L. Dunn"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["United States Marine Corps Systems Command and M2 Technologies"]},{"key":"dc:title","label":"Title","values":["Photon signatures for standoff bomb detection"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.department":["Department of Mechanical and Nuclear Engineering"],"dc:creator":["Loschke, Kyle W."],"dc:date.accessioned":["2008-07-29T16:45:20Z"],"dc:date.available":["2008-07-29T16:45:20Z"],"dc:date.issued":["2008-07-29T16:45:20Z"],"dc:date.published":["2008"],"dc:description.abstract":["The purpose of this research was to develop a technology to quickly identify hidden explosive materials. The developed method needs to be performed at a standoff distance of approximately two meters or more, must have high sensitivity (low false-negative rate) and good specificity (low false-positive rate), and should be able to detect a minimum amount of approximately one gallon (15 lbs) of explosive material. In an effort to meet these goals, a template-matching procedure to aid in the rapid detection of hidden improvised explosive devices was investigated. Multiple photon-scattered responses are being used as a part of a multidimensional signature-based radiation scanning (SBRS) approach in an attempt to detect chemical explosives at safe, standoff distances. The SBRS approach utilizes both neutron and photon interrogation to determine if a target contains explosive material, but the focus of this thesis is on photon interrogation. Beams of photons are used to create back-streamed responses called signatures, which are dependent on the density and the composition of the target. These signatures are compared to templates, which are collections of the same signatures if the interrogated volume contained a significant amount of explosives. The signature analysis produces a single figure-of-merit. A low figure-of-merit indicates an explosive might be present in the target. Experiments have been conducted that show an explosive surrogate (fertilizer) can be distinguished from several inert materials using these photon signatures, proving these signatures to be very useful in this particular method of chemical explosive detection."],"dc:description.advisor":["William L. Dunn"],"dc:description.degree":["Master of Science"],"dc:description.sponsorship":["United States Marine Corps Systems Command and M2 Technologies"],"dc:identifier.uri":["http://hdl.handle.net/2097/894"],"dc:language.iso":["en_US"],"dc:publisher":["Kansas State University"],"dc:rights":["© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s)."],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Improvised explosive device","Photon","Detection"],"dc:subject.proquest":["Engineering, Nuclear (0552)"],"dc:title":["Photon signatures for standoff bomb detection"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_date":["August"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-26T03:08:32Z"}