{"id":{"repo_id":"lancaster","oai_identifier":"oai:eprints.lancs.ac.uk:151920"},"canonical_url":"https://search.ndltd.org/etd/lancaster/oai:eprints.lancs.ac.uk:151920","repository":{"repo_id":"lancaster","name":"Lancaster University","base_url":"https://eprints.lancs.ac.uk/cgi/oai2"},"display":{"title":"New low temperature techniques for electron thermometry and thermal isolation","abstract":"Measuring electron temperature is an important method to understand the stability and coherence of a quantum circuit, since this variable describes how `quiet' the electronic environment is. In this thesis, the construction, calibration and operation of a quantum dot electron thermometer is demonstrated in two different cryostats. Compared to previous implementations of a quantum dot thermometer, the work presented here is unique in that it only requires a single gate connection to calibrate and operate, which simplifies the application of the device substantially. For the thermometer calibration, a physical model of the quantum-dot reservoir system was developed, which reveals information usually obtained from a stability diagram. Electron thermometry was successfully performed with the calibrated thermometer in a 1.0 K to 3.0 K range. With the fastest mode of operation the quantum dot thermometer was shown to have a sensitivity of 3.7±0.3 mK/√Hz at 1.3 K. This device provides a new versatile, sensitive and effective tool for monitoring electron temperature in nanoelectronic devices at cryogenic temperatures. Also in this thesis, several plastic solid-void structures were demonstrated to offer excellent thermal and structural properties at sub-Kelvin temperatures. Good low temperature insulators are extremely useful for support cryogenic components and sample environments without leaking unwanted heat. A structure fabricated from commercially available ABS LEGO elements was shown to be effective at thermally insulating two bodies at sub-Kelvin temperatures, with a thermal conductivity of κ = (8.7±0.3)×10-5 T1.75±0.02 Wm-1K-1. Similar scale 3D printed ABS and PLA gyroid structures were shown to also be effective as low-temperature insulators, having a thermal conductivity of κ = (3.07±0.05)×10-5T1.72±0.02 Wm-1K-1 and κ = 4.45±0.05)×10-5T1.64±0.02 Wm-1K-1, respectively. These samples demonstrate how low temperature insulation can be improved with readily available, fully customisable and affordable components.","abstract_html":"Measuring electron temperature is an important method to understand the stability and coherence of a quantum circuit, since this variable describes how `quiet&#x27; the electronic environment is. In this thesis, the construction, calibration and operation of a quantum dot electron thermometer is demonstrated in two different cryostats. Compared to previous implementations of a quantum dot thermometer, the work presented here is unique in that it only requires a single gate connection to calibrate and operate, which simplifies the application of the device substantially. For the thermometer calibration, a physical model of the quantum-dot reservoir system was developed, which reveals information usually obtained from a stability diagram. Electron thermometry was successfully performed with the calibrated thermometer in a 1.0 K to 3.0 K range. With the fastest mode of operation the quantum dot thermometer was shown to have a sensitivity of 3.7±0.3 mK/√Hz at 1.3 K. This device provides a new versatile, sensitive and effective tool for monitoring electron temperature in nanoelectronic devices at cryogenic temperatures. Also in this thesis, several plastic solid-void structures were demonstrated to offer excellent thermal and structural properties at sub-Kelvin temperatures. Good low temperature insulators are extremely useful for support cryogenic components and sample environments without leaking unwanted heat. A structure fabricated from commercially available ABS LEGO elements was shown to be effective at thermally insulating two bodies at sub-Kelvin temperatures, with a thermal conductivity of κ = (8.7±0.3)×10-5 T1.75±0.02 Wm-1K-1. Similar scale 3D printed ABS and PLA gyroid structures were shown to also be effective as low-temperature insulators, having a thermal conductivity of κ = (3.07±0.05)×10-5T1.72±0.02 Wm-1K-1 and κ = 4.45±0.05)×10-5T1.64±0.02 Wm-1K-1, respectively. These samples demonstrate how low temperature insulation can be improved with readily available, fully customisable and affordable components.","abstract_has_math":false,"creators":["Chawner, Joshua","Prance, Jonathan","Pashkin, Yuri"],"institution":"Lancaster University","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-25T20:21:26Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://eprints.lancs.ac.uk/id/eprint/151920/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://eprints.lancs.ac.uk/id/eprint/151920/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Alancaster%3Aoai%3Aeprints.lancs.ac.uk%3A151920","prefix":"oai_dc"},"source_record":{"url":"https://eprints.lancs.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.lancs.ac.uk%3A151920","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Chawner, Joshua","Prance, Jonathan","Pashkin, Yuri"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021"]},{"key":"dc:date.issued","label":"Date","values":["2021"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["Lancaster University"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Physics"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Lancaster University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.lancs.ac.uk/id/eprint/151920/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Measuring electron temperature is an important method to understand the stability and coherence of a quantum circuit, since this variable describes how `quiet' the electronic environment is. In this thesis, the construction, calibration and operation of a quantum dot electron thermometer is demonstrated in two different cryostats. Compared to previous implementations of a quantum dot thermometer, the work presented here is unique in that it only requires a single gate connection to calibrate and operate, which simplifies the application of the device substantially. For the thermometer calibration, a physical model of the quantum-dot reservoir system was developed, which reveals information usually obtained from a stability diagram. Electron thermometry was successfully performed with the calibrated thermometer in a 1.0 K to 3.0 K range. With the fastest mode of operation the quantum dot thermometer was shown to have a sensitivity of 3.7±0.3 mK/√Hz at 1.3 K. This device provides a new versatile, sensitive and effective tool for monitoring electron temperature in nanoelectronic devices at cryogenic temperatures. Also in this thesis, several plastic solid-void structures were demonstrated to offer excellent thermal and structural properties at sub-Kelvin temperatures. Good low temperature insulators are extremely useful for support cryogenic components and sample environments without leaking unwanted heat. A structure fabricated from commercially available ABS LEGO elements was shown to be effective at thermally insulating two bodies at sub-Kelvin temperatures, with a thermal conductivity of κ = (8.7±0.3)×10-5 T1.75±0.02 Wm-1K-1. Similar scale 3D printed ABS and PLA gyroid structures were shown to also be effective as low-temperature insulators, having a thermal conductivity of κ = (3.07±0.05)×10-5T1.72±0.02 Wm-1K-1 and κ = 4.45±0.05)×10-5T1.64±0.02 Wm-1K-1, respectively. These samples demonstrate how low temperature insulation can be improved with readily available, fully customisable and affordable components."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["New low temperature techniques for electron thermometry and thermal isolation"]}]}],"canonical_facts":{"dc:creator":["Chawner, Joshua","Prance, Jonathan","Pashkin, Yuri"],"dc:date":["2021"],"dc:date.issued":["2021"],"dc:description.abstract":["Measuring electron temperature is an important method to understand the stability and coherence of a quantum circuit, since this variable describes how `quiet' the electronic environment is. In this thesis, the construction, calibration and operation of a quantum dot electron thermometer is demonstrated in two different cryostats. Compared to previous implementations of a quantum dot thermometer, the work presented here is unique in that it only requires a single gate connection to calibrate and operate, which simplifies the application of the device substantially. For the thermometer calibration, a physical model of the quantum-dot reservoir system was developed, which reveals information usually obtained from a stability diagram. Electron thermometry was successfully performed with the calibrated thermometer in a 1.0 K to 3.0 K range. With the fastest mode of operation the quantum dot thermometer was shown to have a sensitivity of 3.7±0.3 mK/√Hz at 1.3 K. This device provides a new versatile, sensitive and effective tool for monitoring electron temperature in nanoelectronic devices at cryogenic temperatures. Also in this thesis, several plastic solid-void structures were demonstrated to offer excellent thermal and structural properties at sub-Kelvin temperatures. Good low temperature insulators are extremely useful for support cryogenic components and sample environments without leaking unwanted heat. A structure fabricated from commercially available ABS LEGO elements was shown to be effective at thermally insulating two bodies at sub-Kelvin temperatures, with a thermal conductivity of κ = (8.7±0.3)×10-5 T1.75±0.02 Wm-1K-1. Similar scale 3D printed ABS and PLA gyroid structures were shown to also be effective as low-temperature insulators, having a thermal conductivity of κ = (3.07±0.05)×10-5T1.72±0.02 Wm-1K-1 and κ = 4.45±0.05)×10-5T1.64±0.02 Wm-1K-1, respectively. These samples demonstrate how low temperature insulation can be improved with readily available, fully customisable and affordable components."],"dc:format":["text"],"dc:identifier.uri":["https://eprints.lancs.ac.uk/id/eprint/151920/"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["Lancaster University"],"dc:publisher.department":["Physics"],"dc:publisher.institution":["Lancaster University"],"dcterms:accessrights":["public"],"dc:title":["New low temperature techniques for electron thermometry and thermal isolation"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-25T20:21:26Z"}