{"id":{"repo_id":"lethbridge","oai_identifier":"oai:opus.uleth.ca:10133/122"},"canonical_url":"https://search.ndltd.org/etd/lethbridge/oai:opus.uleth.ca:10133/122","repository":{"repo_id":"lethbridge","name":"University of Lethbridge","base_url":"https://opus.uleth.ca/server/oai/request"},"display":{"title":"An infrared radiometer for millimeter astronomy","abstract":"The performance of existing and planned millimeter and submillimeter astronomical arrays is limited by fluctuations in the amount of atmosperic water vapor along the atenna's line of sight. Correcting the resulting phase distortion of the received signals is seen as a significant technological challenge. Measurements of the variation in the line-of-sight water vapor abundance at the level of 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monior operating at abundance at the level 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monitor operating at infrared wavelengths which shows considerable promise for this application. Improvements in, and future plans for, the second generation water vapor monitor currently under development are also discussed.","abstract_html":"The performance of existing and planned millimeter and submillimeter astronomical arrays is limited by fluctuations in the amount of atmosperic water vapor along the atenna&#x27;s line of sight. Correcting the resulting phase distortion of the received signals is seen as a significant technological challenge. Measurements of the variation in the line-of-sight water vapor abundance at the level of 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monior operating at abundance at the level 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monitor operating at infrared wavelengths which shows considerable promise for this application. Improvements in, and future plans for, the second generation water vapor monitor currently under development are also discussed.","abstract_has_math":false,"creators":["Smith, Graeme John","University of Lethbridge. Faculty of Arts and Science"],"institution":"Lethbridge, Alta. : University of Lethbridge, Faculty of Arts and Science, 2000","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Naylor, David A."],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000","date_published":"2000","updated_at":"2026-11-18T19:29:59Z","subjects":["Dissertations, Academic","Millimeter astronomy","Infrared astronomy","Visible infrared spin scan radiometer"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:10133/122"],"render_values":[{"text":"hdl:10133/122","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10133/122","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10133/122","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://opus.uleth.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopus.uleth.ca%3A10133%2F122","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Naylor, David A."]},{"key":"dc:creator","label":"Author","values":["Smith, Graeme John","University of Lethbridge. Faculty of Arts and Science"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-04-25T14:41:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-04-25T14:41:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2000"]},{"key":"dc:publisher","label":"Institution","values":["Lethbridge, Alta. : University of Lethbridge, Faculty of Arts and Science, 2000"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Physics"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Arts and Science"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Thesis (University of Lethbridge. Faculty of Arts and Science)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dissertations, Academic","Millimeter astronomy","Infrared astronomy","Visible infrared spin scan radiometer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:10133/122"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10133/122"]},{"key":"mods:identifier.uri","label":"Mods Identifier URI","values":["https://hdl.handle.net/10133/122"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["xiii, 167 leaves : ill. ; 28 cm."]},{"key":"dc:description.abstract","label":"Abstract","values":["The performance of existing and planned millimeter and submillimeter astronomical arrays is limited by fluctuations in the amount of atmosperic water vapor along the atenna's line of sight. Correcting the resulting phase distortion of the received signals is seen as a significant technological challenge. Measurements of the variation in the line-of-sight water vapor abundance at the level of 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monior operating at abundance at the level 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monitor operating at infrared wavelengths which shows considerable promise for this application. Improvements in, and future plans for, the second generation water vapor monitor currently under development are also discussed."]},{"key":"dc:description.other","label":"Dc Description Other","values":["The performance of existing and planned millimeter and submillimeter astronomical arrays is limited by fluctuations in the amount of atmosperic water vapor along the atenna's line of sight. Correcting the resulting phase distortion of the received signals is seen as a significant technological challenge. Measurements of the variation in the line-of-sight water vapor abundance at the level of 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monior operating at abundance at the level 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monitor operating at infrared wavelengths which shows considerable promise for this application. Improvements in, and future plans for, the second generation water vapor monitor currently under development are also discussed."]},{"key":"dc:title","label":"Title","values":["An infrared radiometer for millimeter astronomy"]},{"key":"mods:dateaccessioned","label":"Mods Dateaccessioned","values":["2007-04-25T14:41:07Z"]},{"key":"mods:dateavailable","label":"Mods Dateavailable","values":["2007-04-25T14:41:07Z"]},{"key":"mods:languageterm.rfc3066","label":"Mods Languageterm RFC 3066","values":["en_US"]},{"key":"mods:namepart","label":"Mods Namepart","values":["Naylor, David A.","Smith, Graeme John","University of Lethbridge. Faculty of Arts and Science"]},{"key":"mods:roleterm.text","label":"Mods Roleterm Text","values":["supervisor","author"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Naylor, David A."],"dc:creator":["Smith, Graeme John","University of Lethbridge. Faculty of Arts and Science"],"dc:date.accessioned":["2007-04-25T14:41:07Z"],"dc:date.available":["2007-04-25T14:41:07Z"],"dc:date.issued":["2000"],"dc:description":["xiii, 167 leaves : ill. ; 28 cm."],"dc:description.abstract":["The performance of existing and planned millimeter and submillimeter astronomical arrays is limited by fluctuations in the amount of atmosperic water vapor along the atenna's line of sight. Correcting the resulting phase distortion of the received signals is seen as a significant technological challenge. Measurements of the variation in the line-of-sight water vapor abundance at the level of 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monior operating at abundance at the level 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monitor operating at infrared wavelengths which shows considerable promise for this application. Improvements in, and future plans for, the second generation water vapor monitor currently under development are also discussed."],"dc:description.other":["The performance of existing and planned millimeter and submillimeter astronomical arrays is limited by fluctuations in the amount of atmosperic water vapor along the atenna's line of sight. Correcting the resulting phase distortion of the received signals is seen as a significant technological challenge. Measurements of the variation in the line-of-sight water vapor abundance at the level of 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monior operating at abundance at the level 1 micron precipitable water vapor on a time scale of 1 second and at arbitrary antenna positions are required. This thesis describes the design of, and preliminary results obtained with, a water vapor monitor operating at infrared wavelengths which shows considerable promise for this application. Improvements in, and future plans for, the second generation water vapor monitor currently under development are also discussed."],"dc:identifier":["hdl:10133/122"],"dc:identifier.uri":["https://hdl.handle.net/10133/122"],"dc:language.iso":["en_US"],"dc:publisher":["Lethbridge, Alta. : University of Lethbridge, Faculty of Arts and Science, 2000"],"dc:publisher.department":["Department of Physics"],"dc:publisher.faculty":["Arts and Science"],"dc:relation.ispartofseries":["Thesis (University of Lethbridge. Faculty of Arts and Science)"],"dc:subject":["Dissertations, Academic","Millimeter astronomy","Infrared astronomy","Visible infrared spin scan radiometer"],"dc:title":["An infrared radiometer for millimeter astronomy"],"dc:type":["Thesis"],"mods:dateaccessioned":["2007-04-25T14:41:07Z"],"mods:dateavailable":["2007-04-25T14:41:07Z"],"mods:identifier.uri":["https://hdl.handle.net/10133/122"],"mods:languageterm.rfc3066":["en_US"],"mods:namepart":["Naylor, David A.","Smith, Graeme John","University of Lethbridge. Faculty of Arts and Science"],"mods:roleterm.text":["supervisor","author"],"others:access_status":["open.access"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-18T19:29:59Z"}