{"id":{"repo_id":"lethbridge","oai_identifier":"oai:opus.uleth.ca:10133/6214"},"canonical_url":"https://search.ndltd.org/etd/lethbridge/oai:opus.uleth.ca:10133/6214","repository":{"repo_id":"lethbridge","name":"University of Lethbridge","base_url":"https://opus.uleth.ca/server/oai/request"},"display":{"title":"Development of the dispersing component for a cryogenic post-dispersed polarizing Fourier transform spectrometer","abstract":"Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting grating spectrometers to post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This thesis discusses the development of a cryogenic (4 K) reflection grating spectrometer which operates over the wavelength range from 285 - 500 µm and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance.","abstract_html":"Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting grating spectrometers to post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This thesis discusses the development of a cryogenic (4 K) reflection grating spectrometer which operates over the wavelength range from 285 - 500 µm and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance.","abstract_has_math":false,"creators":["Anderson, Alicia May","University of Lethbridge. Faculty of Arts and Science"],"institution":"Lethbridge, Alta. : University of Lethbridge, Dept. of Physics and Astonomy","degree_name":null,"degree_level":"Masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Naylor, David A."],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T05:21:30Z","subjects":["far infrared","Fourier transform spectrometer","diffraction efficiency","diffraction grating","astronomy and astrophysics","cryogenic instrumentation","Fourier transform infrared spectroscopy","Low temperature engineering","Diffraction gratings--Design and construction","Infrared astronomy--Instruments--Design and construction","Submillimeter astronomy--Instruments--Design and construction","Dissertations, Academic"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10133/6214","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10133/6214","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://opus.uleth.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopus.uleth.ca%3A10133%2F6214","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Naylor, David A."]},{"key":"dc:creator","label":"Author","values":["Anderson, Alicia May","University of Lethbridge. Faculty of Arts and Science"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-05-27T22:37:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-05-27T22:37:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Lethbridge, Alta. : University of Lethbridge, Dept. of Physics and Astonomy"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Physics & Astronomy"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Arts and Science"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["Thesis (University of Lethbridge. Faculty of Arts and Science)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["far infrared","Fourier transform spectrometer","diffraction efficiency","diffraction grating","astronomy and astrophysics","cryogenic instrumentation","Fourier transform infrared spectroscopy","Low temperature engineering","Diffraction gratings--Design and construction","Infrared astronomy--Instruments--Design and construction","Submillimeter astronomy--Instruments--Design and construction","Dissertations, Academic"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["0605","0596","0606"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights.proquest","label":"Dc Rights Proquest","values":["Yes"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10133/6214"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting grating spectrometers to post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This thesis discusses the development of a cryogenic (4 K) reflection grating spectrometer which operates over the wavelength range from 285 - 500 µm and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance."]},{"key":"dc:title","label":"Title","values":["Development of the dispersing component for a cryogenic post-dispersed polarizing Fourier transform spectrometer"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Naylor, David A."],"dc:creator":["Anderson, Alicia May","University of Lethbridge. Faculty of Arts and Science"],"dc:date.accessioned":["2022-05-27T22:37:34Z"],"dc:date.available":["2022-05-27T22:37:34Z"],"dc:date.issued":["2022"],"dc:description.abstract":["Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting grating spectrometers to post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This thesis discusses the development of a cryogenic (4 K) reflection grating spectrometer which operates over the wavelength range from 285 - 500 µm and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance."],"dc:identifier.uri":["https://hdl.handle.net/10133/6214"],"dc:language.iso":["en_US"],"dc:publisher":["Lethbridge, Alta. : University of Lethbridge, Dept. of Physics and Astonomy"],"dc:publisher.department":["Department of Physics & Astronomy"],"dc:publisher.faculty":["Arts and Science"],"dc:relation.ispartofseries":["Thesis (University of Lethbridge. Faculty of Arts and Science)"],"dc:rights.proquest":["Yes"],"dc:subject":["far infrared","Fourier transform spectrometer","diffraction efficiency","diffraction grating","astronomy and astrophysics","cryogenic instrumentation","Fourier transform infrared spectroscopy","Low temperature engineering","Diffraction gratings--Design and construction","Infrared astronomy--Instruments--Design and construction","Submillimeter astronomy--Instruments--Design and construction","Dissertations, Academic"],"dc:subject.proquest":["0605","0596","0606"],"dc:title":["Development of the dispersing component for a cryogenic post-dispersed polarizing Fourier transform spectrometer"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_level":["Masters"]},"updated_at":"2026-11-19T05:21:30Z"}