{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/1040"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/1040","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Non-linear structural analysis of shear connected cavity walls subject to wind load","abstract":"This study presents a comprehensive structural analysis of shear connected cavity walls, vertically spanned, subject to lateral load. The cavity wall investigated in this study is a masonry assembly comprising two wythes separated by a continuous cavity and tied together, via non-conventional metal connectors. Since the introduction of the new Block Shear$\\sp{\\rm TM}$ Connector the role and the structural behaviour of traditional cavity walls with flexible ties changed significantly. Also, the new, Canadian Standards Association Standard CSA CAN3-S304.1-M94 Masonry Design for Buildings-Limit States Design introduces strength and serviceability requirements that must be met in design. For both reasons, the author recognized a great need for a rational approach and more realistic prediction of structural performance of the cavity wall. Currently, the masonry industry is looking into a method to take advantage of the unused structural potential of the outer wythe by reducing the material and construction costs. The realistic determination of the response of either a plain or reinforced shear connected cavity wall demands knowledge of the inelastic behaviour of all constituent parts and the ability to incorporate these into a rational analysis of the real structure. Since a precise analysis is highly complex, this requires a reasonable compromise between reality and the use of simplifying assumptions: firstly, in the formulation of material and geometric properties, secondly in simulating the structure with a mathematical model and finally, in the use of the principles of mechanics. The proposed Method of Imposed Rotations which falls into the category of Separation Methods is a special type of non-linear analysis. It is based on the Principle of Superposition, with material non-linear stress-strain relationships, and consequently non-linear constitutive relationships accounted for. (Abstract shortened by UMI.)","abstract_html":"This study presents a comprehensive structural analysis of shear connected cavity walls, vertically spanned, subject to lateral load. The cavity wall investigated in this study is a masonry assembly comprising two wythes separated by a continuous cavity and tied together, via non-conventional metal connectors. Since the introduction of the new Block Shear$\\sp{\\rm TM}$ Connector the role and the structural behaviour of traditional cavity walls with flexible ties changed significantly. Also, the new, Canadian Standards Association Standard CSA CAN3-S304.1-M94 Masonry Design for Buildings-Limit States Design introduces strength and serviceability requirements that must be met in design. For both reasons, the author recognized a great need for a rational approach and more realistic prediction of structural performance of the cavity wall. Currently, the masonry industry is looking into a method to take advantage of the unused structural potential of the outer wythe by reducing the material and construction costs. The realistic determination of the response of either a plain or reinforced shear connected cavity wall demands knowledge of the inelastic behaviour of all constituent parts and the ability to incorporate these into a rational analysis of the real structure. Since a precise analysis is highly complex, this requires a reasonable compromise between reality and the use of simplifying assumptions: firstly, in the formulation of material and geometric properties, secondly in simulating the structure with a mathematical model and finally, in the use of the principles of mechanics. The proposed Method of Imposed Rotations which falls into the category of Separation Methods is a special type of non-linear analysis. It is based on the Principle of Superposition, with material non-linear stress-strain relationships, and consequently non-linear constitutive relationships accounted for. (Abstract shortened by UMI.)","abstract_has_math":true,"creators":["Siveski, Zlatan"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1997,"date_issued":"1997-04-01T00:00:00Z","date_published":"1997-04-01T00:00:00Z","updated_at":"2026-11-19T09:10:16Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/1040","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/1040","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F1040","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F1040","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Siveski, Zlatan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-05-15T15:26:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-05-15T15:26:56Z"]},{"key":"dc:date.issued","label":"Date","values":["1997-04-01T00:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/1040"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study presents a comprehensive structural analysis of shear connected cavity walls, vertically spanned, subject to lateral load. The cavity wall investigated in this study is a masonry assembly comprising two wythes separated by a continuous cavity and tied together, via non-conventional metal connectors. Since the introduction of the new Block Shear$\\sp{\\rm TM}$ Connector the role and the structural behaviour of traditional cavity walls with flexible ties changed significantly. Also, the new, Canadian Standards Association Standard CSA CAN3-S304.1-M94 Masonry Design for Buildings-Limit States Design introduces strength and serviceability requirements that must be met in design. For both reasons, the author recognized a great need for a rational approach and more realistic prediction of structural performance of the cavity wall. Currently, the masonry industry is looking into a method to take advantage of the unused structural potential of the outer wythe by reducing the material and construction costs. The realistic determination of the response of either a plain or reinforced shear connected cavity wall demands knowledge of the inelastic behaviour of all constituent parts and the ability to incorporate these into a rational analysis of the real structure. Since a precise analysis is highly complex, this requires a reasonable compromise between reality and the use of simplifying assumptions: firstly, in the formulation of material and geometric properties, secondly in simulating the structure with a mathematical model and finally, in the use of the principles of mechanics. The proposed Method of Imposed Rotations which falls into the category of Separation Methods is a special type of non-linear analysis. It is based on the Principle of Superposition, with material non-linear stress-strain relationships, and consequently non-linear constitutive relationships accounted for. (Abstract shortened by UMI.)"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["7161723 bytes","184 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf","text/plain"]},{"key":"dc:title","label":"Title","values":["Non-linear structural analysis of shear connected cavity walls subject to wind load"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Siveski, Zlatan"],"dc:date.accessioned":["2007-05-15T15:26:56Z"],"dc:date.available":["2007-05-15T15:26:56Z"],"dc:date.issued":["1997-04-01T00:00:00Z"],"dc:description.abstract":["This study presents a comprehensive structural analysis of shear connected cavity walls, vertically spanned, subject to lateral load. The cavity wall investigated in this study is a masonry assembly comprising two wythes separated by a continuous cavity and tied together, via non-conventional metal connectors. Since the introduction of the new Block Shear$\\sp{\\rm TM}$ Connector the role and the structural behaviour of traditional cavity walls with flexible ties changed significantly. Also, the new, Canadian Standards Association Standard CSA CAN3-S304.1-M94 Masonry Design for Buildings-Limit States Design introduces strength and serviceability requirements that must be met in design. For both reasons, the author recognized a great need for a rational approach and more realistic prediction of structural performance of the cavity wall. Currently, the masonry industry is looking into a method to take advantage of the unused structural potential of the outer wythe by reducing the material and construction costs. The realistic determination of the response of either a plain or reinforced shear connected cavity wall demands knowledge of the inelastic behaviour of all constituent parts and the ability to incorporate these into a rational analysis of the real structure. Since a precise analysis is highly complex, this requires a reasonable compromise between reality and the use of simplifying assumptions: firstly, in the formulation of material and geometric properties, secondly in simulating the structure with a mathematical model and finally, in the use of the principles of mechanics. The proposed Method of Imposed Rotations which falls into the category of Separation Methods is a special type of non-linear analysis. It is based on the Principle of Superposition, with material non-linear stress-strain relationships, and consequently non-linear constitutive relationships accounted for. (Abstract shortened by UMI.)"],"dc:format.extent":["7161723 bytes","184 bytes"],"dc:format.mimetype":["application/pdf","text/plain"],"dc:identifier.uri":["http://hdl.handle.net/1993/1040"],"dc:language.iso":["eng"],"dc:title":["Non-linear structural analysis of shear connected cavity walls subject to wind load"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:10:16Z"}