{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/18328"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/18328","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Calibration of an ultrasound tomography system for medical imaging with 2D contrast-source inversion","abstract":"This dissertation describes two possible methods for the calibration of an ultrasound tomography system developed at University of Manitoba's Electromagnetic Imaging Laboratory for imaging with the contrast-source inversion algorithm. The calibration techniques are adapted from existing procedures employed for microwave tomography. A theoretical model of these calibration principles is developed in order to provide a rationale for the effectiveness of the proposed procedures. The applicability of such an imaging algorithm and calibration methods in the context of ultrasound are discussed. Also presented are 2D and 3D finite-difference time-domain update equations for the simulation of acoustic wave propagation in inhomogeneous media. Details regarding the application of an absorbing boundary-condition, point-source modelling and the treatment of penetrable objects are included in this document.","abstract_html":"This dissertation describes two possible methods for the calibration of an ultrasound tomography system developed at University of Manitoba&#x27;s Electromagnetic Imaging Laboratory for imaging with the contrast-source inversion algorithm. The calibration techniques are adapted from existing procedures employed for microwave tomography. A theoretical model of these calibration principles is developed in order to provide a rationale for the effectiveness of the proposed procedures. The applicability of such an imaging algorithm and calibration methods in the context of ultrasound are discussed. Also presented are 2D and 3D finite-difference time-domain update equations for the simulation of acoustic wave propagation in inhomogeneous media. Details regarding the application of an absorbing boundary-condition, point-source modelling and the treatment of penetrable objects are included in this document.","abstract_has_math":false,"creators":["Faucher, Gabriel Paul"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["LoVetri, Joe (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":["Sherif, Sherif (Electrical and Computer Engineering)","Popplewell, Neil (Mechanical and Manufacturing Engineering)"],"year":2013,"date_issued":"2013-04-03","date_published":"2013-04-03","updated_at":"2026-11-19T09:06:01Z","subjects":["Ultrasound","Imaging","Medical","Calibration","Inversion","Finite-difference time-domain (FDTD)","Fem","Contrast source inversion (CSI)","Tomography","Contrast-source","Breast","Cancer","Acoustic","Inhomogeneous","Acoustical","Modelling"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/18328","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/18328","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F18328","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F18328","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sherif, Sherif (Electrical and Computer Engineering)","Popplewell, Neil (Mechanical and Manufacturing Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["LoVetri, Joe (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Faucher, Gabriel Paul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-04-03T15:39:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-04-03T15:39:58Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-04-03"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ultrasound","Imaging","Medical","Calibration","Inversion","Finite-difference time-domain (FDTD)","Fem","Contrast source inversion (CSI)","Tomography","Contrast-source","Breast","Cancer","Acoustic","Inhomogeneous","Acoustical","Modelling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/18328"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This dissertation describes two possible methods for the calibration of an ultrasound tomography system developed at University of Manitoba's Electromagnetic Imaging Laboratory for imaging with the contrast-source inversion algorithm. The calibration techniques are adapted from existing procedures employed for microwave tomography. A theoretical model of these calibration principles is developed in order to provide a rationale for the effectiveness of the proposed procedures. The applicability of such an imaging algorithm and calibration methods in the context of ultrasound are discussed. Also presented are 2D and 3D finite-difference time-domain update equations for the simulation of acoustic wave propagation in inhomogeneous media. Details regarding the application of an absorbing boundary-condition, point-source modelling and the treatment of penetrable objects are included in this document."]},{"key":"dc:description.note","label":"Dc Description Note","values":["May 2013"]},{"key":"dc:title","label":"Title","values":["Calibration of an ultrasound tomography system for medical imaging with 2D contrast-source inversion"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Sherif, Sherif (Electrical and Computer Engineering)","Popplewell, Neil (Mechanical and Manufacturing Engineering)"],"dc:contributor.supervisor":["LoVetri, Joe (Electrical and Computer Engineering)"],"dc:creator":["Faucher, Gabriel Paul"],"dc:date.accessioned":["2013-04-03T15:39:58Z"],"dc:date.available":["2013-04-03T15:39:58Z"],"dc:date.issued":["2013-04-03"],"dc:description.abstract":["This dissertation describes two possible methods for the calibration of an ultrasound tomography system developed at University of Manitoba's Electromagnetic Imaging Laboratory for imaging with the contrast-source inversion algorithm. The calibration techniques are adapted from existing procedures employed for microwave tomography. A theoretical model of these calibration principles is developed in order to provide a rationale for the effectiveness of the proposed procedures. The applicability of such an imaging algorithm and calibration methods in the context of ultrasound are discussed. Also presented are 2D and 3D finite-difference time-domain update equations for the simulation of acoustic wave propagation in inhomogeneous media. Details regarding the application of an absorbing boundary-condition, point-source modelling and the treatment of penetrable objects are included in this document."],"dc:description.note":["May 2013"],"dc:identifier.uri":["http://hdl.handle.net/1993/18328"],"dc:language.iso":["eng"],"dc:subject":["Ultrasound","Imaging","Medical","Calibration","Inversion","Finite-difference time-domain (FDTD)","Fem","Contrast source inversion (CSI)","Tomography","Contrast-source","Breast","Cancer","Acoustic","Inhomogeneous","Acoustical","Modelling"],"dc:title":["Calibration of an ultrasound tomography system for medical imaging with 2D contrast-source inversion"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:06:01Z"}