{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/2006"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/2006","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Evaluation of shear/peel bond strengths of orthodontic attachments to moist and dry enamel","abstract":"The purpose of this study was to evaluate the shear-peel bond strengths of orthodontic attachments bonded to enamel surfaces under varying conditions. A light-cured composite adhesive was compared to a cyanoacrylate adhesive and a composite hybrid adhesive. The shear-peel bond strengths in this study are stated as 24 hours vs. 6 months and were as follows: Transbond(tm) XT/dry (10.57 +- 2.83 MPa vs 12.23 +- 3.14 MPa), Assure(tm)/dry (6.93 +- 2.2 MPa vs 8.18 +- 1.39 MPa), Smartbond(R)/dry (3.91 +- 1.17 MPa vs 4.11 +- 1.96 MPa), Transbond(tm) XT/moist (0.14 +- 0.31 MPa vs 0 +- 0 MPa), Assure(tm)/moist (6.03 +- 1.77 MPa vs 6.86 +- 2.81 MPa), and Smartbond(R)/moist (3.22 +- 0.52 MPa vs 2.4 +- 0.96 MPa). There was a statistically significant difference (p < 0.05) between (1) the different adhesives (2) the dry and moist conditions of Transbond(tm) XT. There was no statistically significant difference (p > 0.05) between (1) the dry and moist conditions of Assure(tm) and Smartbond(R) (2) the 24 hour and 6 month time frame for all adhesives. (Abstract shortened by UMI.)","abstract_html":"The purpose of this study was to evaluate the shear-peel bond strengths of orthodontic attachments bonded to enamel surfaces under varying conditions. A light-cured composite adhesive was compared to a cyanoacrylate adhesive and a composite hybrid adhesive. The shear-peel bond strengths in this study are stated as 24 hours vs. 6 months and were as follows: Transbond(tm) XT/dry (10.57 +- 2.83 MPa vs 12.23 +- 3.14 MPa), Assure(tm)/dry (6.93 +- 2.2 MPa vs 8.18 +- 1.39 MPa), Smartbond(R)/dry (3.91 +- 1.17 MPa vs 4.11 +- 1.96 MPa), Transbond(tm) XT/moist (0.14 +- 0.31 MPa vs 0 +- 0 MPa), Assure(tm)/moist (6.03 +- 1.77 MPa vs 6.86 +- 2.81 MPa), and Smartbond(R)/moist (3.22 +- 0.52 MPa vs 2.4 +- 0.96 MPa). There was a statistically significant difference (p &lt; 0.05) between (1) the different adhesives (2) the dry and moist conditions of Transbond(tm) XT. There was no statistically significant difference (p &gt; 0.05) between (1) the dry and moist conditions of Assure(tm) and Smartbond(R) (2) the 24 hour and 6 month time frame for all adhesives. (Abstract shortened by UMI.)","abstract_has_math":false,"creators":["Nemeth, Benjamin Robert"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Preventive Dental Science","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000-12-01T00:00:00Z","date_published":"2000-12-01T00:00:00Z","updated_at":"2026-11-19T09:12:27Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/2006","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/2006","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F2006","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F2006","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Nemeth, Benjamin Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-05-22T15:12:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-05-22T15:12:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2000-12-01T00:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Preventive Dental Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/2006"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was to evaluate the shear-peel bond strengths of orthodontic attachments bonded to enamel surfaces under varying conditions. A light-cured composite adhesive was compared to a cyanoacrylate adhesive and a composite hybrid adhesive. The shear-peel bond strengths in this study are stated as 24 hours vs. 6 months and were as follows: Transbond(tm) XT/dry (10.57 +- 2.83 MPa vs 12.23 +- 3.14 MPa), Assure(tm)/dry (6.93 +- 2.2 MPa vs 8.18 +- 1.39 MPa), Smartbond(R)/dry (3.91 +- 1.17 MPa vs 4.11 +- 1.96 MPa), Transbond(tm) XT/moist (0.14 +- 0.31 MPa vs 0 +- 0 MPa), Assure(tm)/moist (6.03 +- 1.77 MPa vs 6.86 +- 2.81 MPa), and Smartbond(R)/moist (3.22 +- 0.52 MPa vs 2.4 +- 0.96 MPa). There was a statistically significant difference (p < 0.05) between (1) the different adhesives (2) the dry and moist conditions of Transbond(tm) XT. There was no statistically significant difference (p > 0.05) between (1) the dry and moist conditions of Assure(tm) and Smartbond(R) (2) the 24 hour and 6 month time frame for all adhesives. (Abstract shortened by UMI.)"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["5202153 bytes","184 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf","text/plain"]},{"key":"dc:title","label":"Title","values":["Evaluation of shear/peel bond strengths of orthodontic attachments to moist and dry enamel"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Nemeth, Benjamin Robert"],"dc:date.accessioned":["2007-05-22T15:12:42Z"],"dc:date.available":["2007-05-22T15:12:42Z"],"dc:date.issued":["2000-12-01T00:00:00Z"],"dc:description.abstract":["The purpose of this study was to evaluate the shear-peel bond strengths of orthodontic attachments bonded to enamel surfaces under varying conditions. A light-cured composite adhesive was compared to a cyanoacrylate adhesive and a composite hybrid adhesive. The shear-peel bond strengths in this study are stated as 24 hours vs. 6 months and were as follows: Transbond(tm) XT/dry (10.57 +- 2.83 MPa vs 12.23 +- 3.14 MPa), Assure(tm)/dry (6.93 +- 2.2 MPa vs 8.18 +- 1.39 MPa), Smartbond(R)/dry (3.91 +- 1.17 MPa vs 4.11 +- 1.96 MPa), Transbond(tm) XT/moist (0.14 +- 0.31 MPa vs 0 +- 0 MPa), Assure(tm)/moist (6.03 +- 1.77 MPa vs 6.86 +- 2.81 MPa), and Smartbond(R)/moist (3.22 +- 0.52 MPa vs 2.4 +- 0.96 MPa). There was a statistically significant difference (p < 0.05) between (1) the different adhesives (2) the dry and moist conditions of Transbond(tm) XT. There was no statistically significant difference (p > 0.05) between (1) the dry and moist conditions of Assure(tm) and Smartbond(R) (2) the 24 hour and 6 month time frame for all adhesives. (Abstract shortened by UMI.)"],"dc:format.extent":["5202153 bytes","184 bytes"],"dc:format.mimetype":["application/pdf","text/plain"],"dc:identifier.uri":["http://hdl.handle.net/1993/2006"],"dc:language.iso":["eng"],"dc:title":["Evaluation of shear/peel bond strengths of orthodontic attachments to moist and dry enamel"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Preventive Dental Science"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:12:27Z"}