{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/22015"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/22015","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"The prediction of the longitudinal load factors for a simplified A-402M transmission line system using ANSYS","abstract":"ASCE Manual No.74 (2010) and the Electric Power Research Institute (EPRI, 1997) provide methods for calculating the unbalanced longitudinal loads on a transmission line due to a wire breakage. The calculated loads from the two are different. In this study, a simplified transmission line was created using the equivalent geometric properties of a detailed transmission line. Non-linear dynamic analyses of the 10-span simplified transmission line due to cable breakage events in the first span were studied using ANSYS. The analyzed longitudinal loads were found to vary for different S/S, S/I, and K’s as specified in the EPRI. An equation for the longitudinal load factor as a function of the S/S, S/I, and K was then formulated based on the analysis. The longitudinal load factors from the formulated equation were found to be almost double those given by the ASCE manual and comparable to those calculated using the EPRI formulation.","abstract_html":"ASCE Manual No.74 (2010) and the Electric Power Research Institute (EPRI, 1997) provide methods for calculating the unbalanced longitudinal loads on a transmission line due to a wire breakage. The calculated loads from the two are different. In this study, a simplified transmission line was created using the equivalent geometric properties of a detailed transmission line. Non-linear dynamic analyses of the 10-span simplified transmission line due to cable breakage events in the first span were studied using ANSYS. The analyzed longitudinal loads were found to vary for different S/S, S/I, and K’s as specified in the EPRI. An equation for the longitudinal load factor as a function of the S/S, S/I, and K was then formulated based on the analysis. The longitudinal load factors from the formulated equation were found to be almost double those given by the ASCE manual and comparable to those calculated using the EPRI formulation.","abstract_has_math":false,"creators":["Gilarski, Andrew"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Rattanawangcharoen, Nipon (Civil Engineering)"],"committee_chairs":[],"committee_members":["Kell, Jon (Manitoba Hydro)","Hashemian, Fariborz (Civil Engineering)","Wang, Quan (Mechanical Engineering)"],"year":2013,"date_issued":"2013-08-02","date_published":"2013-08-02","updated_at":"2026-11-19T09:05:17Z","subjects":["ANSYS","LLF","A-402M","Transmission","Prediction","Simplified"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/22015","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/22015","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F22015","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F22015","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kell, Jon (Manitoba Hydro)","Hashemian, Fariborz (Civil Engineering)","Wang, Quan (Mechanical Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Rattanawangcharoen, Nipon (Civil Engineering)"]},{"key":"dc:creator","label":"Author","values":["Gilarski, Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-08-02T18:15:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-08-02T18:15:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-08-02"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["ANSYS","LLF","A-402M","Transmission","Prediction","Simplified"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/22015"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["ASCE Manual No.74 (2010) and the Electric Power Research Institute (EPRI, 1997) provide methods for calculating the unbalanced longitudinal loads on a transmission line due to a wire breakage. The calculated loads from the two are different. In this study, a simplified transmission line was created using the equivalent geometric properties of a detailed transmission line. Non-linear dynamic analyses of the 10-span simplified transmission line due to cable breakage events in the first span were studied using ANSYS. The analyzed longitudinal loads were found to vary for different S/S, S/I, and K’s as specified in the EPRI. An equation for the longitudinal load factor as a function of the S/S, S/I, and K was then formulated based on the analysis. The longitudinal load factors from the formulated equation were found to be almost double those given by the ASCE manual and comparable to those calculated using the EPRI formulation."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2013"]},{"key":"dc:title","label":"Title","values":["The prediction of the longitudinal load factors for a simplified A-402M transmission line system using ANSYS"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Kell, Jon (Manitoba Hydro)","Hashemian, Fariborz (Civil Engineering)","Wang, Quan (Mechanical Engineering)"],"dc:contributor.supervisor":["Rattanawangcharoen, Nipon (Civil Engineering)"],"dc:creator":["Gilarski, Andrew"],"dc:date.accessioned":["2013-08-02T18:15:18Z"],"dc:date.available":["2013-08-02T18:15:18Z"],"dc:date.issued":["2013-08-02"],"dc:description.abstract":["ASCE Manual No.74 (2010) and the Electric Power Research Institute (EPRI, 1997) provide methods for calculating the unbalanced longitudinal loads on a transmission line due to a wire breakage. The calculated loads from the two are different. In this study, a simplified transmission line was created using the equivalent geometric properties of a detailed transmission line. Non-linear dynamic analyses of the 10-span simplified transmission line due to cable breakage events in the first span were studied using ANSYS. The analyzed longitudinal loads were found to vary for different S/S, S/I, and K’s as specified in the EPRI. An equation for the longitudinal load factor as a function of the S/S, S/I, and K was then formulated based on the analysis. The longitudinal load factors from the formulated equation were found to be almost double those given by the ASCE manual and comparable to those calculated using the EPRI formulation."],"dc:description.note":["October 2013"],"dc:identifier.uri":["http://hdl.handle.net/1993/22015"],"dc:language.iso":["eng"],"dc:subject":["ANSYS","LLF","A-402M","Transmission","Prediction","Simplified"],"dc:title":["The prediction of the longitudinal load factors for a simplified A-402M transmission line system using ANSYS"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:05:17Z"}