{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/22111"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/22111","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Optimizing an Off-Grid Electrical System in Brochet, Manitoba, Canada","abstract":"Brochet is a remote, off-grid community located in Northern Manitoba, Canada. The existing diesel generating system is characterized by high economic and environmental costs. As the existing diesel generators are nearing the end of their operational lifespan, this study uses the HOMER model to determine an optimum electricity system design at Brochet that has high electrical reliability, least cost, and low emissions. Three potential power generation options were considered and evaluated, namely: 1) only diesel, 2) only wind, 3) a mix of both. The wind-diesel hybrid system performed best for all the evaluation criteria. While maintaining high reliability, this hybrid system design resulted in 19 % reduction in electricity cost, and 30 % reduction of CO2 when compared to the existing electricity system at Brochet. Thus, this study concludes that the wind-diesel hybrid system is the optimum electricity system design for Brochet and proposes this system replace the existing system.","abstract_html":"Brochet is a remote, off-grid community located in Northern Manitoba, Canada. The existing diesel generating system is characterized by high economic and environmental costs. As the existing diesel generators are nearing the end of their operational lifespan, this study uses the HOMER model to determine an optimum electricity system design at Brochet that has high electrical reliability, least cost, and low emissions. Three potential power generation options were considered and evaluated, namely: 1) only diesel, 2) only wind, 3) a mix of both. The wind-diesel hybrid system performed best for all the evaluation criteria. While maintaining high reliability, this hybrid system design resulted in 19 % reduction in electricity cost, and 30 % reduction of CO2 when compared to the existing electricity system at Brochet. Thus, this study concludes that the wind-diesel hybrid system is the optimum electricity system design for Brochet and proposes this system replace the existing system.","abstract_has_math":false,"creators":["Bhattarai, Prasid Ram"],"institution":null,"degree_name":null,"degree_level":"Master of Natural Resources Management (M.N.R.M.)","degree_discipline":"Natural Resources Management","degree_department":null,"school":null,"contributors":[],"advisors":["Thompson, Shirley (Natural Resources Institute)"],"committee_chairs":[],"committee_members":["Polyzois, Dimos (Civil Engineering)","Neudoerffer, Cynthia (Canadian Foodgrains Bank)"],"year":2013,"date_issued":"2013-08-26","date_published":"2013-08-26","updated_at":"2026-11-19T09:06:46Z","subjects":["HOMER","Off-Grid Community","Optimization","Wind-Diesel Hybrid"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/22111","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/22111","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F22111","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F22111","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Polyzois, Dimos (Civil Engineering)","Neudoerffer, Cynthia (Canadian Foodgrains Bank)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Thompson, Shirley (Natural Resources Institute)"]},{"key":"dc:creator","label":"Author","values":["Bhattarai, Prasid Ram"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-08-26T17:13:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-08-26T17:13:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-08-26"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Natural Resources Management"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Natural Resources Management (M.N.R.M.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["HOMER","Off-Grid Community","Optimization","Wind-Diesel Hybrid"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/22111"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Brochet is a remote, off-grid community located in Northern Manitoba, Canada. The existing diesel generating system is characterized by high economic and environmental costs. As the existing diesel generators are nearing the end of their operational lifespan, this study uses the HOMER model to determine an optimum electricity system design at Brochet that has high electrical reliability, least cost, and low emissions. Three potential power generation options were considered and evaluated, namely: 1) only diesel, 2) only wind, 3) a mix of both. The wind-diesel hybrid system performed best for all the evaluation criteria. While maintaining high reliability, this hybrid system design resulted in 19 % reduction in electricity cost, and 30 % reduction of CO2 when compared to the existing electricity system at Brochet. Thus, this study concludes that the wind-diesel hybrid system is the optimum electricity system design for Brochet and proposes this system replace the existing system."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2013"]},{"key":"dc:title","label":"Title","values":["Optimizing an Off-Grid Electrical System in Brochet, Manitoba, Canada"]},{"key":"local:admin","label":"Local Admin","values":["yes"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Polyzois, Dimos (Civil Engineering)","Neudoerffer, Cynthia (Canadian Foodgrains Bank)"],"dc:contributor.supervisor":["Thompson, Shirley (Natural Resources Institute)"],"dc:creator":["Bhattarai, Prasid Ram"],"dc:date.accessioned":["2013-08-26T17:13:02Z"],"dc:date.available":["2013-08-26T17:13:02Z"],"dc:date.issued":["2013-08-26"],"dc:description.abstract":["Brochet is a remote, off-grid community located in Northern Manitoba, Canada. The existing diesel generating system is characterized by high economic and environmental costs. As the existing diesel generators are nearing the end of their operational lifespan, this study uses the HOMER model to determine an optimum electricity system design at Brochet that has high electrical reliability, least cost, and low emissions. Three potential power generation options were considered and evaluated, namely: 1) only diesel, 2) only wind, 3) a mix of both. The wind-diesel hybrid system performed best for all the evaluation criteria. While maintaining high reliability, this hybrid system design resulted in 19 % reduction in electricity cost, and 30 % reduction of CO2 when compared to the existing electricity system at Brochet. Thus, this study concludes that the wind-diesel hybrid system is the optimum electricity system design for Brochet and proposes this system replace the existing system."],"dc:description.note":["October 2013"],"dc:identifier.uri":["http://hdl.handle.net/1993/22111"],"dc:language.iso":["eng"],"dc:subject":["HOMER","Off-Grid Community","Optimization","Wind-Diesel Hybrid"],"dc:title":["Optimizing an Off-Grid Electrical System in Brochet, Manitoba, Canada"],"dc:type":["master thesis"],"local:admin":["yes"],"others:access_status":["open.access"],"thesis:degree_discipline":["Natural Resources Management"],"thesis:degree_level":["Master of Natural Resources Management (M.N.R.M.)"]},"updated_at":"2026-11-19T09:06:46Z"}