{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/2368"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/2368","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Two-phase flow in horizontal impacting tee junctions, current state of the art","abstract":"The present investigation presents a summary of the state of the art in our understanding of the phase distribution in horizontal impacting tee junctions during two-phase flow. The currently existing data base was reviewed and the effects of different parameters on the phase distribution were investigated. These parameters include JL1, JG1, P1, x1, inlet flow regime, and inlet momentum-flux ratio. It was found that there is a serious lack of pressure-drop data and high-inlet-quality phase-distribution data. The effect of JL1 was such that as JL1 increases with JG1 fixed, the line, or curve that represents the data rotates in a clockwise direction. It is demonstrated that none of the available models/correlations can provide accurate predictions of magnitude and trend for all inlet conditions. The design of a test facility that is capable of generating phase-distribution and pressure-drop data for low-pressure, air-water two-phase flow through an impacting tee junction is given. (Abstract shortened by UMI.)","abstract_html":"The present investigation presents a summary of the state of the art in our understanding of the phase distribution in horizontal impacting tee junctions during two-phase flow. The currently existing data base was reviewed and the effects of different parameters on the phase distribution were investigated. These parameters include JL1, JG1, P1, x1, inlet flow regime, and inlet momentum-flux ratio. It was found that there is a serious lack of pressure-drop data and high-inlet-quality phase-distribution data. The effect of JL1 was such that as JL1 increases with JG1 fixed, the line, or curve that represents the data rotates in a clockwise direction. It is demonstrated that none of the available models/correlations can provide accurate predictions of magnitude and trend for all inlet conditions. The design of a test facility that is capable of generating phase-distribution and pressure-drop data for low-pressure, air-water two-phase flow through an impacting tee junction is given. (Abstract shortened by UMI.)","abstract_has_math":false,"creators":["El-Shaboury, Ahmed M. F."],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Mechanical and Manufacturing Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000-05-01T00:00:00Z","date_published":"2000-05-01T00:00:00Z","updated_at":"2026-11-19T09:06:57Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/2368","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/2368","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F2368","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F2368","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["El-Shaboury, Ahmed M. F."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-06-01T19:22:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-06-01T19:22:39Z"]},{"key":"dc:date.issued","label":"Date","values":["2000-05-01T00:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Manufacturing Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/2368"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The present investigation presents a summary of the state of the art in our understanding of the phase distribution in horizontal impacting tee junctions during two-phase flow. The currently existing data base was reviewed and the effects of different parameters on the phase distribution were investigated. These parameters include JL1, JG1, P1, x1, inlet flow regime, and inlet momentum-flux ratio. It was found that there is a serious lack of pressure-drop data and high-inlet-quality phase-distribution data. The effect of JL1 was such that as JL1 increases with JG1 fixed, the line, or curve that represents the data rotates in a clockwise direction. It is demonstrated that none of the available models/correlations can provide accurate predictions of magnitude and trend for all inlet conditions. The design of a test facility that is capable of generating phase-distribution and pressure-drop data for low-pressure, air-water two-phase flow through an impacting tee junction is given. (Abstract shortened by UMI.)"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["8905273 bytes","184 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf","text/plain"]},{"key":"dc:title","label":"Title","values":["Two-phase flow in horizontal impacting tee junctions, current state of the art"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["El-Shaboury, Ahmed M. F."],"dc:date.accessioned":["2007-06-01T19:22:39Z"],"dc:date.available":["2007-06-01T19:22:39Z"],"dc:date.issued":["2000-05-01T00:00:00Z"],"dc:description.abstract":["The present investigation presents a summary of the state of the art in our understanding of the phase distribution in horizontal impacting tee junctions during two-phase flow. The currently existing data base was reviewed and the effects of different parameters on the phase distribution were investigated. These parameters include JL1, JG1, P1, x1, inlet flow regime, and inlet momentum-flux ratio. It was found that there is a serious lack of pressure-drop data and high-inlet-quality phase-distribution data. The effect of JL1 was such that as JL1 increases with JG1 fixed, the line, or curve that represents the data rotates in a clockwise direction. It is demonstrated that none of the available models/correlations can provide accurate predictions of magnitude and trend for all inlet conditions. The design of a test facility that is capable of generating phase-distribution and pressure-drop data for low-pressure, air-water two-phase flow through an impacting tee junction is given. (Abstract shortened by UMI.)"],"dc:format.extent":["8905273 bytes","184 bytes"],"dc:format.mimetype":["application/pdf","text/plain"],"dc:identifier.uri":["http://hdl.handle.net/1993/2368"],"dc:language.iso":["eng"],"dc:title":["Two-phase flow in horizontal impacting tee junctions, current state of the art"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical and Manufacturing Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:06:57Z"}