{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/2386"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/2386","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Computer based on-line diagnostics of insulation quality of high voltage apparatus","abstract":"The safe and reliable operation of a power system is directly related to the insulation condition of high voltage apparatus in service, which may age and deteriorate under normal operating conditions. Therefore, the detection of insulation quality of high voltage apparatus is important. This task can be implemented advantageously by the measurement of dissipation factor and capacitance using on-line digital methods, since these methods require no service interruption thus resulting in low labor cost. Moreover, on-line measurements under operating voltage are more helpful in the assessment of the status of the insulation. In this work, a computer-aided system for on-line monitoring dissipation factor and capacitance was developed based on a method, which employs the Discrete Fourier Transform (DFT). The DFT is performed on the scaled down analog voltage and current signals obtained using a Digital Storage Oscilloscope (DSO) board, and results are displayed using the graphic user interface which is implemented with software Labview. To optimize system performance, software simulation and laboratory tests were carried out. Based on the results, optimal values of measurement parameters have been suggested. Field tests were conducted at Manitoba Hydro's Dorsey station to evaluate the insulation of a 230KV current transformer unit using the developed system.","abstract_html":"The safe and reliable operation of a power system is directly related to the insulation condition of high voltage apparatus in service, which may age and deteriorate under normal operating conditions. Therefore, the detection of insulation quality of high voltage apparatus is important. This task can be implemented advantageously by the measurement of dissipation factor and capacitance using on-line digital methods, since these methods require no service interruption thus resulting in low labor cost. Moreover, on-line measurements under operating voltage are more helpful in the assessment of the status of the insulation. In this work, a computer-aided system for on-line monitoring dissipation factor and capacitance was developed based on a method, which employs the Discrete Fourier Transform (DFT). The DFT is performed on the scaled down analog voltage and current signals obtained using a Digital Storage Oscilloscope (DSO) board, and results are displayed using the graphic user interface which is implemented with software Labview. To optimize system performance, software simulation and laboratory tests were carried out. Based on the results, optimal values of measurement parameters have been suggested. Field tests were conducted at Manitoba Hydro&#x27;s Dorsey station to evaluate the insulation of a 230KV current transformer unit using the developed system.","abstract_has_math":false,"creators":["Wang, Pei"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000-05-01T00:00:00Z","date_published":"2000-05-01T00:00:00Z","updated_at":"2026-11-19T09:06:46Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/2386","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/2386","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F2386","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F2386","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Wang, Pei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-06-01T19:23:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-06-01T19:23:23Z"]},{"key":"dc:date.issued","label":"Date","values":["2000-05-01T00:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/2386"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The safe and reliable operation of a power system is directly related to the insulation condition of high voltage apparatus in service, which may age and deteriorate under normal operating conditions. Therefore, the detection of insulation quality of high voltage apparatus is important. This task can be implemented advantageously by the measurement of dissipation factor and capacitance using on-line digital methods, since these methods require no service interruption thus resulting in low labor cost. Moreover, on-line measurements under operating voltage are more helpful in the assessment of the status of the insulation. In this work, a computer-aided system for on-line monitoring dissipation factor and capacitance was developed based on a method, which employs the Discrete Fourier Transform (DFT). The DFT is performed on the scaled down analog voltage and current signals obtained using a Digital Storage Oscilloscope (DSO) board, and results are displayed using the graphic user interface which is implemented with software Labview. To optimize system performance, software simulation and laboratory tests were carried out. Based on the results, optimal values of measurement parameters have been suggested. Field tests were conducted at Manitoba Hydro's Dorsey station to evaluate the insulation of a 230KV current transformer unit using the developed system."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["3183582 bytes","184 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf","text/plain"]},{"key":"dc:title","label":"Title","values":["Computer based on-line diagnostics of insulation quality of high voltage apparatus"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Wang, Pei"],"dc:date.accessioned":["2007-06-01T19:23:23Z"],"dc:date.available":["2007-06-01T19:23:23Z"],"dc:date.issued":["2000-05-01T00:00:00Z"],"dc:description.abstract":["The safe and reliable operation of a power system is directly related to the insulation condition of high voltage apparatus in service, which may age and deteriorate under normal operating conditions. Therefore, the detection of insulation quality of high voltage apparatus is important. This task can be implemented advantageously by the measurement of dissipation factor and capacitance using on-line digital methods, since these methods require no service interruption thus resulting in low labor cost. Moreover, on-line measurements under operating voltage are more helpful in the assessment of the status of the insulation. In this work, a computer-aided system for on-line monitoring dissipation factor and capacitance was developed based on a method, which employs the Discrete Fourier Transform (DFT). The DFT is performed on the scaled down analog voltage and current signals obtained using a Digital Storage Oscilloscope (DSO) board, and results are displayed using the graphic user interface which is implemented with software Labview. To optimize system performance, software simulation and laboratory tests were carried out. Based on the results, optimal values of measurement parameters have been suggested. Field tests were conducted at Manitoba Hydro's Dorsey station to evaluate the insulation of a 230KV current transformer unit using the developed system."],"dc:format.extent":["3183582 bytes","184 bytes"],"dc:format.mimetype":["application/pdf","text/plain"],"dc:identifier.uri":["http://hdl.handle.net/1993/2386"],"dc:language.iso":["eng"],"dc:title":["Computer based on-line diagnostics of insulation quality of high voltage apparatus"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:06:46Z"}