{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/23937"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/23937","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Determination of impulse generator setup for transient testing of power transformers using optimization-enabled electromagnetic transient simulation","abstract":"Natural lightning strikes induce impulsive overvoltages on transmission lines and its terminal equipment. These overvoltages may cause failures in insulation mechanisms of electrical devices in the power system. It is important to test the insulation strength of a device against these impulsive overvoltages. Usually, Marx generators are used to generate impulse waveforms for testing purposes. A novel approach is proposed to obtain resistor settings of a Marx generator for impulse testing of power transformers. This approach enables us to overcome most of the major challenges in the commonly used trial-and-error method, including excessive time consumption and potential damage to the transformer. The proposed approach uses the frequency response of the transformer to synthesize a circuit model. Then, a genetic algorithm based optimization-enabled electromagnetic transient simulation approach is used to obtain the resistor settings. The proposed approach is validated by a real impulse test conducted on a three phase power transformer.","abstract_html":"Natural lightning strikes induce impulsive overvoltages on transmission lines and its terminal equipment. These overvoltages may cause failures in insulation mechanisms of electrical devices in the power system. It is important to test the insulation strength of a device against these impulsive overvoltages. Usually, Marx generators are used to generate impulse waveforms for testing purposes. A novel approach is proposed to obtain resistor settings of a Marx generator for impulse testing of power transformers. This approach enables us to overcome most of the major challenges in the commonly used trial-and-error method, including excessive time consumption and potential damage to the transformer. The proposed approach uses the frequency response of the transformer to synthesize a circuit model. Then, a genetic algorithm based optimization-enabled electromagnetic transient simulation approach is used to obtain the resistor settings. The proposed approach is validated by a real impulse test conducted on a three phase power transformer.","abstract_has_math":false,"creators":["Samarawickrama, Kasun Chamara"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Kordi, Behzad (Electrical and Computer Engineering) Gole, Aniruddha M. (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":["Rajapakse, Athula (Electrical and Computer Engineering)","Wu, Christine (Mechanical Engineering)"],"year":2014,"date_issued":"2014-09-02","date_published":"2014-09-02","updated_at":"2026-11-19T09:09:25Z","subjects":["Lightning impulse test","Genetic algorithm","Frequency response analysis","Electromagnetic transient simulation"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/23937","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/23937","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F23937","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F23937","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Rajapakse, Athula (Electrical and Computer Engineering)","Wu, Christine (Mechanical Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Kordi, Behzad (Electrical and Computer Engineering) Gole, Aniruddha M. (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Samarawickrama, Kasun Chamara"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-09-02T18:19:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-09-02T18:19:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-09-02"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Lightning impulse test","Genetic algorithm","Frequency response analysis","Electromagnetic transient simulation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/23937"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Natural lightning strikes induce impulsive overvoltages on transmission lines and its terminal equipment. These overvoltages may cause failures in insulation mechanisms of electrical devices in the power system. It is important to test the insulation strength of a device against these impulsive overvoltages. Usually, Marx generators are used to generate impulse waveforms for testing purposes. A novel approach is proposed to obtain resistor settings of a Marx generator for impulse testing of power transformers. This approach enables us to overcome most of the major challenges in the commonly used trial-and-error method, including excessive time consumption and potential damage to the transformer. The proposed approach uses the frequency response of the transformer to synthesize a circuit model. Then, a genetic algorithm based optimization-enabled electromagnetic transient simulation approach is used to obtain the resistor settings. The proposed approach is validated by a real impulse test conducted on a three phase power transformer."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2014"]},{"key":"dc:title","label":"Title","values":["Determination of impulse generator setup for transient testing of power transformers using optimization-enabled electromagnetic transient simulation"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Rajapakse, Athula (Electrical and Computer Engineering)","Wu, Christine (Mechanical Engineering)"],"dc:contributor.supervisor":["Kordi, Behzad (Electrical and Computer Engineering) Gole, Aniruddha M. (Electrical and Computer Engineering)"],"dc:creator":["Samarawickrama, Kasun Chamara"],"dc:date.accessioned":["2014-09-02T18:19:18Z"],"dc:date.available":["2014-09-02T18:19:18Z"],"dc:date.issued":["2014-09-02"],"dc:description.abstract":["Natural lightning strikes induce impulsive overvoltages on transmission lines and its terminal equipment. These overvoltages may cause failures in insulation mechanisms of electrical devices in the power system. It is important to test the insulation strength of a device against these impulsive overvoltages. Usually, Marx generators are used to generate impulse waveforms for testing purposes. A novel approach is proposed to obtain resistor settings of a Marx generator for impulse testing of power transformers. This approach enables us to overcome most of the major challenges in the commonly used trial-and-error method, including excessive time consumption and potential damage to the transformer. The proposed approach uses the frequency response of the transformer to synthesize a circuit model. Then, a genetic algorithm based optimization-enabled electromagnetic transient simulation approach is used to obtain the resistor settings. The proposed approach is validated by a real impulse test conducted on a three phase power transformer."],"dc:description.note":["October 2014"],"dc:identifier.uri":["http://hdl.handle.net/1993/23937"],"dc:language.iso":["eng"],"dc:subject":["Lightning impulse test","Genetic algorithm","Frequency response analysis","Electromagnetic transient simulation"],"dc:title":["Determination of impulse generator setup for transient testing of power transformers using optimization-enabled electromagnetic transient simulation"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:09:25Z"}