{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/23940"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/23940","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Spectroscopic imaging using quadrature optical coherence tomography","abstract":"Optical Coherence Tomography (OCT) is a subsurface imaging technique with many biomedical and industrial applications. In this thesis, we describe our design and implementation of a time domain OCT system. We used this system to obtain OCT images of objects that are important in different applications. We also used an existing quadrature OCT system to obtain both real and imaginary parts of an OCT image. We introduced a new interpretation of OCT images as the 2nd derivative of the scattering potential of an object. To obtain this scattering potential from its 2nd derivative, we implemented a method of definite integration in the spectral-domain. The obtained scattering potential was used to separate the scattering profile from the absorption profile of an object. We applied this new spectroscopic imaging method to quadrature OCT images of different objects.","abstract_html":"Optical Coherence Tomography (OCT) is a subsurface imaging technique with many biomedical and industrial applications. In this thesis, we describe our design and implementation of a time domain OCT system. We used this system to obtain OCT images of objects that are important in different applications. We also used an existing quadrature OCT system to obtain both real and imaginary parts of an OCT image. We introduced a new interpretation of OCT images as the 2nd derivative of the scattering potential of an object. To obtain this scattering potential from its 2nd derivative, we implemented a method of definite integration in the spectral-domain. The obtained scattering potential was used to separate the scattering profile from the absorption profile of an object. We applied this new spectroscopic imaging method to quadrature OCT images of different objects.","abstract_has_math":false,"creators":["Thanusutiyabhorn, Pimrapat"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Sherif, Sherif (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":["Major, Arkady (Electrical and Computer Engineering)","Paliwal, Jitendra (Biosystems Engineering)"],"year":2014,"date_issued":"2014-09-02","date_published":"2014-09-02","updated_at":"2026-11-19T09:06:17Z","subjects":["Spectroscopic imaging","Optical coherence tomography","Quadrature interferometer","Biomedical imaging"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/23940","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/23940","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F23940","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F23940","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Major, Arkady (Electrical and Computer Engineering)","Paliwal, Jitendra (Biosystems Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Sherif, Sherif (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Thanusutiyabhorn, Pimrapat"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-09-02T18:55:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-09-02T18:55:23Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-09-02"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Spectroscopic imaging","Optical coherence tomography","Quadrature interferometer","Biomedical imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/23940"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Optical Coherence Tomography (OCT) is a subsurface imaging technique with many biomedical and industrial applications. In this thesis, we describe our design and implementation of a time domain OCT system. We used this system to obtain OCT images of objects that are important in different applications. We also used an existing quadrature OCT system to obtain both real and imaginary parts of an OCT image. We introduced a new interpretation of OCT images as the 2nd derivative of the scattering potential of an object. To obtain this scattering potential from its 2nd derivative, we implemented a method of definite integration in the spectral-domain. The obtained scattering potential was used to separate the scattering profile from the absorption profile of an object. We applied this new spectroscopic imaging method to quadrature OCT images of different objects."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2014"]},{"key":"dc:title","label":"Title","values":["Spectroscopic imaging using quadrature optical coherence tomography"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Major, Arkady (Electrical and Computer Engineering)","Paliwal, Jitendra (Biosystems Engineering)"],"dc:contributor.supervisor":["Sherif, Sherif (Electrical and Computer Engineering)"],"dc:creator":["Thanusutiyabhorn, Pimrapat"],"dc:date.accessioned":["2014-09-02T18:55:23Z"],"dc:date.available":["2014-09-02T18:55:23Z"],"dc:date.issued":["2014-09-02"],"dc:description.abstract":["Optical Coherence Tomography (OCT) is a subsurface imaging technique with many biomedical and industrial applications. In this thesis, we describe our design and implementation of a time domain OCT system. We used this system to obtain OCT images of objects that are important in different applications. We also used an existing quadrature OCT system to obtain both real and imaginary parts of an OCT image. We introduced a new interpretation of OCT images as the 2nd derivative of the scattering potential of an object. To obtain this scattering potential from its 2nd derivative, we implemented a method of definite integration in the spectral-domain. The obtained scattering potential was used to separate the scattering profile from the absorption profile of an object. We applied this new spectroscopic imaging method to quadrature OCT images of different objects."],"dc:description.note":["October 2014"],"dc:identifier.uri":["http://hdl.handle.net/1993/23940"],"dc:language.iso":["eng"],"dc:subject":["Spectroscopic imaging","Optical coherence tomography","Quadrature interferometer","Biomedical imaging"],"dc:title":["Spectroscopic imaging using quadrature optical coherence tomography"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:06:17Z"}