{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/2573"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/2573","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Comparative study of knot performance and ease of manipulation of monofilament and braided sutures for arthroscopic applications","abstract":"The primary objective of this study is to determine whether alternative monofilament sutures, such as poly (glycolidetrimethylenecarbonate-co-dioxanone) (Biosyn(R)) and polypropylene (Prolene(R)) or braided poly (ethylene terephthalate), i.e. polyester (Surgidac (R)), provide superior knot performance and equivalent ease of manipulation to the existing absorbable PDS(R) suture. An in vitro experiment was designed in which both Duncan and Snyder knotted loops were tied from four different suture materials: PDS(R), Biosyn(R), Prolene(R) and Surgidac (R), using a standard arthroscopic knot pusher (Sixth Finger) and an Arthrex(R) practice box. The ease of manipulation was evaluated by measuring the time required to tie the knots, and the knot performance was assessed by performing first a cyclic fatigue test, and then a tensile loop pull test to failure under saline using an Instron(R) Universal tester. Among the criteria for evaluating the mechanical performance of the knotted loop were the loop elongation at 30N of applied force, the force required to extend the loop by 6% (3mm), called the loop holding capacity, as well as the knot security and maximum elongation at failure. The results were analyzed statistically by two-way analysis of variance in order to identify significant differences between the dependent variables. (Abstract shortened by UMI.)","abstract_html":"The primary objective of this study is to determine whether alternative monofilament sutures, such as poly (glycolidetrimethylenecarbonate-co-dioxanone) (Biosyn(R)) and polypropylene (Prolene(R)) or braided poly (ethylene terephthalate), i.e. polyester (Surgidac (R)), provide superior knot performance and equivalent ease of manipulation to the existing absorbable PDS(R) suture. An in vitro experiment was designed in which both Duncan and Snyder knotted loops were tied from four different suture materials: PDS(R), Biosyn(R), Prolene(R) and Surgidac (R), using a standard arthroscopic knot pusher (Sixth Finger) and an Arthrex(R) practice box. The ease of manipulation was evaluated by measuring the time required to tie the knots, and the knot performance was assessed by performing first a cyclic fatigue test, and then a tensile loop pull test to failure under saline using an Instron(R) Universal tester. Among the criteria for evaluating the mechanical performance of the knotted loop were the loop elongation at 30N of applied force, the force required to extend the loop by 6% (3mm), called the loop holding capacity, as well as the knot security and maximum elongation at failure. The results were analyzed statistically by two-way analysis of variance in order to identify significant differences between the dependent variables. (Abstract shortened by UMI.)","abstract_has_math":false,"creators":["Li, Xiaoli"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Textile Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000-05-01T00:00:00Z","date_published":"2000-05-01T00:00:00Z","updated_at":"2026-11-19T09:12:09Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/2573","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/2573","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F2573","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F2573","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Li, Xiaoli"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-07-12T17:49:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-07-12T17:49:28Z"]},{"key":"dc:date.issued","label":"Date","values":["2000-05-01T00:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Textile Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/2573"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The primary objective of this study is to determine whether alternative monofilament sutures, such as poly (glycolidetrimethylenecarbonate-co-dioxanone) (Biosyn(R)) and polypropylene (Prolene(R)) or braided poly (ethylene terephthalate), i.e. polyester (Surgidac (R)), provide superior knot performance and equivalent ease of manipulation to the existing absorbable PDS(R) suture. An in vitro experiment was designed in which both Duncan and Snyder knotted loops were tied from four different suture materials: PDS(R), Biosyn(R), Prolene(R) and Surgidac (R), using a standard arthroscopic knot pusher (Sixth Finger) and an Arthrex(R) practice box. The ease of manipulation was evaluated by measuring the time required to tie the knots, and the knot performance was assessed by performing first a cyclic fatigue test, and then a tensile loop pull test to failure under saline using an Instron(R) Universal tester. Among the criteria for evaluating the mechanical performance of the knotted loop were the loop elongation at 30N of applied force, the force required to extend the loop by 6% (3mm), called the loop holding capacity, as well as the knot security and maximum elongation at failure. The results were analyzed statistically by two-way analysis of variance in order to identify significant differences between the dependent variables. (Abstract shortened by UMI.)"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["4041681 bytes","184 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf","text/plain"]},{"key":"dc:title","label":"Title","values":["Comparative study of knot performance and ease of manipulation of monofilament and braided sutures for arthroscopic applications"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Li, Xiaoli"],"dc:date.accessioned":["2007-07-12T17:49:28Z"],"dc:date.available":["2007-07-12T17:49:28Z"],"dc:date.issued":["2000-05-01T00:00:00Z"],"dc:description.abstract":["The primary objective of this study is to determine whether alternative monofilament sutures, such as poly (glycolidetrimethylenecarbonate-co-dioxanone) (Biosyn(R)) and polypropylene (Prolene(R)) or braided poly (ethylene terephthalate), i.e. polyester (Surgidac (R)), provide superior knot performance and equivalent ease of manipulation to the existing absorbable PDS(R) suture. An in vitro experiment was designed in which both Duncan and Snyder knotted loops were tied from four different suture materials: PDS(R), Biosyn(R), Prolene(R) and Surgidac (R), using a standard arthroscopic knot pusher (Sixth Finger) and an Arthrex(R) practice box. The ease of manipulation was evaluated by measuring the time required to tie the knots, and the knot performance was assessed by performing first a cyclic fatigue test, and then a tensile loop pull test to failure under saline using an Instron(R) Universal tester. Among the criteria for evaluating the mechanical performance of the knotted loop were the loop elongation at 30N of applied force, the force required to extend the loop by 6% (3mm), called the loop holding capacity, as well as the knot security and maximum elongation at failure. The results were analyzed statistically by two-way analysis of variance in order to identify significant differences between the dependent variables. (Abstract shortened by UMI.)"],"dc:format.extent":["4041681 bytes","184 bytes"],"dc:format.mimetype":["application/pdf","text/plain"],"dc:identifier.uri":["http://hdl.handle.net/1993/2573"],"dc:language.iso":["eng"],"dc:title":["Comparative study of knot performance and ease of manipulation of monofilament and braided sutures for arthroscopic applications"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Textile Sciences"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:12:09Z"}