{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/30232"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/30232","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Investigation of the source and occurrence of lead in the Brandon Water Supply System","abstract":"Lead concentrations in drinking water were found to exceed the provincial standard of 10 µg/L in Brandon, Portage la Prairie and Winnipeg, in some locations. Lead dioxide was identified in the scale coating the interior of lead pipes in the Brandon water distribution system. However, during periods of stagnation, free chlorine is used up by the elevated concentrations of natural organic matter (NOM) in the treated water, and lead dioxide is reduced back to more soluble divalent lead, resulting in release of dissolved lead. The removal of NOM and the targeted removal of aquatic humic substances (AHS), thought to be the most reactive fraction of NOM, were investigated as a means of decreasing the reduction of lead dioxide. Contrary to expected results, targeted removal of AHS was not found to have a significant impact on reduction of lead dioxide, while removal of 50% of the NOM non-preferentially was found to significantly decrease the reduction of lead dioxide. This indicates that AHS are not the most reductant fraction of natural organic matter in this particular water.","abstract_html":"Lead concentrations in drinking water were found to exceed the provincial standard of 10 µg/L in Brandon, Portage la Prairie and Winnipeg, in some locations. Lead dioxide was identified in the scale coating the interior of lead pipes in the Brandon water distribution system. However, during periods of stagnation, free chlorine is used up by the elevated concentrations of natural organic matter (NOM) in the treated water, and lead dioxide is reduced back to more soluble divalent lead, resulting in release of dissolved lead. The removal of NOM and the targeted removal of aquatic humic substances (AHS), thought to be the most reactive fraction of NOM, were investigated as a means of decreasing the reduction of lead dioxide. Contrary to expected results, targeted removal of AHS was not found to have a significant impact on reduction of lead dioxide, while removal of 50% of the NOM non-preferentially was found to significantly decrease the reduction of lead dioxide. This indicates that AHS are not the most reductant fraction of natural organic matter in this particular water.","abstract_has_math":false,"creators":["Winning, Lisa"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Gorczyca, Beata (Civil Engineering)"],"committee_chairs":[],"committee_members":["Kalinovich, Indra (Civil Engineering)","Wang, Feiyue (Environment and Geography)"],"year":2015,"date_issued":"2015-01-16","date_published":"2015-01-16","updated_at":"2026-11-19T09:14:46Z","subjects":["Lead","Lead dioxide","Drinking water","Natural organic matter","Aquatic humic substances"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/30232","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/30232","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F30232","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F30232","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kalinovich, Indra (Civil Engineering)","Wang, Feiyue (Environment and Geography)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Gorczyca, Beata (Civil Engineering)"]},{"key":"dc:creator","label":"Author","values":["Winning, Lisa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-01-16T19:12:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-01-16T19:12:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-01-16"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Lead","Lead dioxide","Drinking water","Natural organic matter","Aquatic humic substances"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/30232"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Lead concentrations in drinking water were found to exceed the provincial standard of 10 µg/L in Brandon, Portage la Prairie and Winnipeg, in some locations. Lead dioxide was identified in the scale coating the interior of lead pipes in the Brandon water distribution system. However, during periods of stagnation, free chlorine is used up by the elevated concentrations of natural organic matter (NOM) in the treated water, and lead dioxide is reduced back to more soluble divalent lead, resulting in release of dissolved lead. The removal of NOM and the targeted removal of aquatic humic substances (AHS), thought to be the most reactive fraction of NOM, were investigated as a means of decreasing the reduction of lead dioxide. Contrary to expected results, targeted removal of AHS was not found to have a significant impact on reduction of lead dioxide, while removal of 50% of the NOM non-preferentially was found to significantly decrease the reduction of lead dioxide. This indicates that AHS are not the most reductant fraction of natural organic matter in this particular water."]},{"key":"dc:description.note","label":"Dc Description Note","values":["February 2015"]},{"key":"dc:title","label":"Title","values":["Investigation of the source and occurrence of lead in the Brandon Water Supply System"]},{"key":"local:admin","label":"Local Admin","values":["yes"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Kalinovich, Indra (Civil Engineering)","Wang, Feiyue (Environment and Geography)"],"dc:contributor.supervisor":["Gorczyca, Beata (Civil Engineering)"],"dc:creator":["Winning, Lisa"],"dc:date.accessioned":["2015-01-16T19:12:29Z"],"dc:date.available":["2015-01-16T19:12:29Z"],"dc:date.issued":["2015-01-16"],"dc:description.abstract":["Lead concentrations in drinking water were found to exceed the provincial standard of 10 µg/L in Brandon, Portage la Prairie and Winnipeg, in some locations. Lead dioxide was identified in the scale coating the interior of lead pipes in the Brandon water distribution system. However, during periods of stagnation, free chlorine is used up by the elevated concentrations of natural organic matter (NOM) in the treated water, and lead dioxide is reduced back to more soluble divalent lead, resulting in release of dissolved lead. The removal of NOM and the targeted removal of aquatic humic substances (AHS), thought to be the most reactive fraction of NOM, were investigated as a means of decreasing the reduction of lead dioxide. Contrary to expected results, targeted removal of AHS was not found to have a significant impact on reduction of lead dioxide, while removal of 50% of the NOM non-preferentially was found to significantly decrease the reduction of lead dioxide. This indicates that AHS are not the most reductant fraction of natural organic matter in this particular water."],"dc:description.note":["February 2015"],"dc:identifier.uri":["http://hdl.handle.net/1993/30232"],"dc:language.iso":["eng"],"dc:subject":["Lead","Lead dioxide","Drinking water","Natural organic matter","Aquatic humic substances"],"dc:title":["Investigation of the source and occurrence of lead in the Brandon Water Supply System"],"dc:type":["master thesis"],"local:admin":["yes"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:14:46Z"}