{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/313"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/313","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Precise mass measurements of Cf252 fission fragments with the Canadian penning trap mass spectrometer (CPTMS)","abstract":"The Canadian Penning Trap Mass Spectrometer (CPTMS) located at the ATLAS (Argonne Tandem Linear Accelerator System) facility of Argonne National Laboratory makes precise mass measurements on both stable and unstable isotopes. A 252Cf fission source has been used as the ion source for the unstable isotope mass measurements. This thesis concentrates on the mass measurements of the fission fragments from the 252Cf fission source using the CPTMS system. It is the first time that the masses of such fission fragments have been measured with a mass spectrometer. The masses of 108Tc, 108Ru, 109Ru and 110Ru have been measured to a precision of 10-7. The results have been compared to exiting mass measurements and the Atomic Mass Evaluation (AME2003). In general good agreement between this work and existing data is realized. A few discrepancies are identified.","abstract_html":"The Canadian Penning Trap Mass Spectrometer (CPTMS) located at the ATLAS (Argonne Tandem Linear Accelerator System) facility of Argonne National Laboratory makes precise mass measurements on both stable and unstable isotopes. A 252Cf fission source has been used as the ion source for the unstable isotope mass measurements. This thesis concentrates on the mass measurements of the fission fragments from the 252Cf fission source using the CPTMS system. It is the first time that the masses of such fission fragments have been measured with a mass spectrometer. The masses of 108Tc, 108Ru, 109Ru and 110Ru have been measured to a precision of 10-7. The results have been compared to exiting mass measurements and the Atomic Mass Evaluation (AME2003). In general good agreement between this work and existing data is realized. A few discrepancies are identified.","abstract_has_math":false,"creators":["Wang, Yuyan"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Kumar Satish Sharma, Physics and Astronomy"],"committee_chairs":[],"committee_members":["Ens, Werner (Physics and Astronomy)","Hruska, Frank (Chemistry)"],"year":2007,"date_issued":"2007-03-28T13:16:32Z","date_published":"2007-03-28T13:16:32Z","updated_at":"2026-11-19T09:08:43Z","subjects":["Spectrometer","Mass measurement"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/313","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/313","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F313","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F313","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ens, Werner (Physics and Astronomy)","Hruska, Frank (Chemistry)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Kumar Satish Sharma, Physics and Astronomy"]},{"key":"dc:creator","label":"Author","values":["Wang, Yuyan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-03-28T13:16:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-03-28T13:16:32Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-03-28T13:16:32Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Spectrometer","Mass measurement"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/313"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Canadian Penning Trap Mass Spectrometer (CPTMS) located at the ATLAS (Argonne Tandem Linear Accelerator System) facility of Argonne National Laboratory makes precise mass measurements on both stable and unstable isotopes. A 252Cf fission source has been used as the ion source for the unstable isotope mass measurements. This thesis concentrates on the mass measurements of the fission fragments from the 252Cf fission source using the CPTMS system. It is the first time that the masses of such fission fragments have been measured with a mass spectrometer. The masses of 108Tc, 108Ru, 109Ru and 110Ru have been measured to a precision of 10-7. The results have been compared to exiting mass measurements and the Atomic Mass Evaluation (AME2003). In general good agreement between this work and existing data is realized. A few discrepancies are identified."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2006"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["2729021 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Precise mass measurements of Cf252 fission fragments with the Canadian penning trap mass spectrometer (CPTMS)"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Ens, Werner (Physics and Astronomy)","Hruska, Frank (Chemistry)"],"dc:contributor.supervisor":["Kumar Satish Sharma, Physics and Astronomy"],"dc:creator":["Wang, Yuyan"],"dc:date.accessioned":["2007-03-28T13:16:32Z"],"dc:date.available":["2007-03-28T13:16:32Z"],"dc:date.issued":["2007-03-28T13:16:32Z"],"dc:description.abstract":["The Canadian Penning Trap Mass Spectrometer (CPTMS) located at the ATLAS (Argonne Tandem Linear Accelerator System) facility of Argonne National Laboratory makes precise mass measurements on both stable and unstable isotopes. A 252Cf fission source has been used as the ion source for the unstable isotope mass measurements. This thesis concentrates on the mass measurements of the fission fragments from the 252Cf fission source using the CPTMS system. It is the first time that the masses of such fission fragments have been measured with a mass spectrometer. The masses of 108Tc, 108Ru, 109Ru and 110Ru have been measured to a precision of 10-7. The results have been compared to exiting mass measurements and the Atomic Mass Evaluation (AME2003). In general good agreement between this work and existing data is realized. A few discrepancies are identified."],"dc:description.note":["October 2006"],"dc:format.extent":["2729021 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1993/313"],"dc:language.iso":["eng"],"dc:subject":["Spectrometer","Mass measurement"],"dc:title":["Precise mass measurements of Cf252 fission fragments with the Canadian penning trap mass spectrometer (CPTMS)"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:08:43Z"}