{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/3205"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/3205","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"A microflow cytometer with simultaneous dielectrophoretic actuation for the optical assay and capacitive cytometry of individual fluid suspended bioparticles","abstract":"Fluid suspended biological particles (bioparticles) flowing through a non-uniform electric field are actuated by the induced dielectrophoretic (DEP) force, known to be dependent upon the bioparticles’ dielectric phenotypes. In this work: a 10-1000 kHz DEP actuation potential applied to a co-planar microelectrode array (MEA) induces a DEP force, altering passing bioparticle trajectories as monitored using: (1) an optical assay, in which the lateral bioparticle velocities are estimated from digital video; and (2) a capacitive cytometer, in which a 1.478 GHz capacitance sensor measures the MEA capacitance perturbations induced by passing bioparticles, which is sensitive to the bioparticles’ elevations. The experimentally observed and simulated lateral velocity profiles of actuated polystyrene microspheres (PSS) and viable and heat shocked Saccharomyces cerevisiae cells verify that the bioparticles’ dielectric phenotypes can be inferred from the resultant trajectories due to the balance between the DEP force and the viscous fluid drag force.","abstract_html":"Fluid suspended biological particles (bioparticles) flowing through a non-uniform electric field are actuated by the induced dielectrophoretic (DEP) force, known to be dependent upon the bioparticles’ dielectric phenotypes. In this work: a 10-1000 kHz DEP actuation potential applied to a co-planar microelectrode array (MEA) induces a DEP force, altering passing bioparticle trajectories as monitored using: (1) an optical assay, in which the lateral bioparticle velocities are estimated from digital video; and (2) a capacitive cytometer, in which a 1.478 GHz capacitance sensor measures the MEA capacitance perturbations induced by passing bioparticles, which is sensitive to the bioparticles’ elevations. The experimentally observed and simulated lateral velocity profiles of actuated polystyrene microspheres (PSS) and viable and heat shocked Saccharomyces cerevisiae cells verify that the bioparticles’ dielectric phenotypes can be inferred from the resultant trajectories due to the balance between the DEP force and the viscous fluid drag force.","abstract_has_math":false,"creators":["Romanuik, Sean"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Thomson, Douglas (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":["Bridges, Gregory (Electrical and Computer Engineering)","Lin, Francis (Physics and Astronomy)"],"year":2009,"date_issued":"2009-09-14T21:24:54Z","date_published":"2009-09-14T21:24:54Z","updated_at":"2026-11-19T09:08:57Z","subjects":["Microflow","Microfluidic","Cytometer","Cytometry","Dielectrophoretic","Dielectrophoresis","Interferometer","Interferometric","Capacitive Sensor","Capacitance Sensing","Capacitive Detector","Capacitance Detection","Polystyrene","Optical Assay","Electrokinetic","Actuation","Yeast","Saccharomyces cerevisiae","Single-cell Diagnostic","Single-cell Diagnosis","Dielectric modeling","COMSOL","Tracker","Trajectory","Velocity profile","Capacitive Signature","Capacitance Signature","Microelectrode"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ferrier, G.A., A.N. Hladio, D.J. Thomson, G.E. Bridges, M. Hedayatipoor, S. Olson, and M.R. Freeman (2007). Microfluidic electromanipulation with capacitive detection for cell diagnositc applications, Proc. NSTI 2:214-217.","Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (2008). Capacitance signatures for rapid detection of the polarity of the dielectrophoretic force on single yeast cells, Proc. NSTI 2:589-592.","Ferrier, G.A., A.N. Hladio, D.J. Thomson, G.E. Bridges, M. Hedayatipoor, S. Olson, and M.R. Freeman (2008). Microfluidic electromanipulation with capacitive detection for the mechanical analysis of cells, Biomicrofluidics 2(4-044102):1-13.","Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). A microwave interferometric system for simultaneous actuation and detection of single biological cells, Lab on a Chip.","Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). Rapid classification of biological cells based on dielectrophoretic actuation with simultaneous capacitive detection, Proc. micro-TAS.","Nikolic-Jaric, M., S.F. Romanuik, G.A. Ferrier, G.E. Bridges, M. Butler, K. Sunley, D.J. Thomson, and M.R. Freeman (2009). Microwave frequency sensor for detection of biological cells in microfluidic channels, Biomicrofluidics 3(3-034103):1-15.","Romanuik, S.F., G.A. Ferrier, D.J. Thomson, G.E. Bridges, S. Olson, and M.R. Freeman (2008). All-electronic detection and actuation of single biological cells for lab-on-a-chip applications, Proc. IEEE Sensors 1:634-637.","Romanuik, S.F., G.A. Ferrier, M.N. Jaric, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). Dielectrophoretic actuation and simultaneous detection of individual bioparticles, Advances in Biomedical Sensing, Measurements, Instrumentation, and Systems, Eds. A. Lay-Ekuakille and S.C. Mukhopadhyay, Springer – Verlag."],"render_values":[{"text":"Ferrier, G.A., A.N. Hladio, D.J. Thomson, G.E. Bridges, M. Hedayatipoor, S. Olson, and M.R. Freeman (2007). Microfluidic electromanipulation with capacitive detection for cell diagnositc applications, Proc. NSTI 2:214-217.","href":null,"code":true},{"text":"Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (2008). Capacitance signatures for rapid detection of the polarity of the dielectrophoretic force on single yeast cells, Proc. NSTI 2:589-592.","href":null,"code":true},{"text":"Ferrier, G.A., A.N. Hladio, D.J. Thomson, G.E. Bridges, M. Hedayatipoor, S. Olson, and M.R. Freeman (2008). Microfluidic electromanipulation with capacitive detection for the mechanical analysis of cells, Biomicrofluidics 2(4-044102):1-13.","href":null,"code":true},{"text":"Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). A microwave interferometric system for simultaneous actuation and detection of single biological cells, Lab on a Chip.","href":null,"code":true},{"text":"Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). Rapid classification of biological cells based on dielectrophoretic actuation with simultaneous capacitive detection, Proc. micro-TAS.","href":null,"code":true},{"text":"Nikolic-Jaric, M., S.F. Romanuik, G.A. Ferrier, G.E. Bridges, M. Butler, K. Sunley, D.J. Thomson, and M.R. Freeman (2009). Microwave frequency sensor for detection of biological cells in microfluidic channels, Biomicrofluidics 3(3-034103):1-15.","href":null,"code":true},{"text":"Romanuik, S.F., G.A. Ferrier, D.J. Thomson, G.E. Bridges, S. Olson, and M.R. Freeman (2008). All-electronic detection and actuation of single biological cells for lab-on-a-chip applications, Proc. IEEE Sensors 1:634-637.","href":null,"code":true},{"text":"Romanuik, S.F., G.A. Ferrier, M.N. Jaric, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). Dielectrophoretic actuation and simultaneous detection of individual bioparticles, Advances in Biomedical Sensing, Measurements, Instrumentation, and Systems, Eds. A. Lay-Ekuakille and S.C. Mukhopadhyay, Springer – Verlag.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/3205","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/3205","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F3205","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F3205","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bridges, Gregory (Electrical and Computer Engineering)","Lin, Francis (Physics and Astronomy)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Thomson, Douglas (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Romanuik, Sean"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-09-14T21:24:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-09-14T21:24:54Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-09-14T21:24:54Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microflow","Microfluidic","Cytometer","Cytometry","Dielectrophoretic","Dielectrophoresis","Interferometer","Interferometric","Capacitive Sensor","Capacitance Sensing","Capacitive Detector","Capacitance Detection","Polystyrene","Optical Assay","Electrokinetic","Actuation","Yeast","Saccharomyces cerevisiae","Single-cell Diagnostic","Single-cell Diagnosis","Dielectric modeling","COMSOL","Tracker","Trajectory","Velocity profile","Capacitive Signature","Capacitance Signature","Microelectrode"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ferrier, G.A., A.N. Hladio, D.J. Thomson, G.E. Bridges, M. Hedayatipoor, S. Olson, and M.R. Freeman (2007). Microfluidic electromanipulation with capacitive detection for cell diagnositc applications, Proc. NSTI 2:214-217.","Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (2008). Capacitance signatures for rapid detection of the polarity of the dielectrophoretic force on single yeast cells, Proc. NSTI 2:589-592.","Ferrier, G.A., A.N. Hladio, D.J. Thomson, G.E. Bridges, M. Hedayatipoor, S. Olson, and M.R. Freeman (2008). Microfluidic electromanipulation with capacitive detection for the mechanical analysis of cells, Biomicrofluidics 2(4-044102):1-13.","Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). A microwave interferometric system for simultaneous actuation and detection of single biological cells, Lab on a Chip.","Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). Rapid classification of biological cells based on dielectrophoretic actuation with simultaneous capacitive detection, Proc. micro-TAS.","Nikolic-Jaric, M., S.F. Romanuik, G.A. Ferrier, G.E. Bridges, M. Butler, K. Sunley, D.J. Thomson, and M.R. Freeman (2009). Microwave frequency sensor for detection of biological cells in microfluidic channels, Biomicrofluidics 3(3-034103):1-15.","Romanuik, S.F., G.A. Ferrier, D.J. Thomson, G.E. Bridges, S. Olson, and M.R. Freeman (2008). All-electronic detection and actuation of single biological cells for lab-on-a-chip applications, Proc. IEEE Sensors 1:634-637.","Romanuik, S.F., G.A. Ferrier, M.N. Jaric, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). Dielectrophoretic actuation and simultaneous detection of individual bioparticles, Advances in Biomedical Sensing, Measurements, Instrumentation, and Systems, Eds. A. Lay-Ekuakille and S.C. Mukhopadhyay, Springer – Verlag."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/3205"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Fluid suspended biological particles (bioparticles) flowing through a non-uniform electric field are actuated by the induced dielectrophoretic (DEP) force, known to be dependent upon the bioparticles’ dielectric phenotypes. In this work: a 10-1000 kHz DEP actuation potential applied to a co-planar microelectrode array (MEA) induces a DEP force, altering passing bioparticle trajectories as monitored using: (1) an optical assay, in which the lateral bioparticle velocities are estimated from digital video; and (2) a capacitive cytometer, in which a 1.478 GHz capacitance sensor measures the MEA capacitance perturbations induced by passing bioparticles, which is sensitive to the bioparticles’ elevations. The experimentally observed and simulated lateral velocity profiles of actuated polystyrene microspheres (PSS) and viable and heat shocked Saccharomyces cerevisiae cells verify that the bioparticles’ dielectric phenotypes can be inferred from the resultant trajectories due to the balance between the DEP force and the viscous fluid drag force."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2009"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["12090925 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A microflow cytometer with simultaneous dielectrophoretic actuation for the optical assay and capacitive cytometry of individual fluid suspended bioparticles"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Bridges, Gregory (Electrical and Computer Engineering)","Lin, Francis (Physics and Astronomy)"],"dc:contributor.supervisor":["Thomson, Douglas (Electrical and Computer Engineering)"],"dc:creator":["Romanuik, Sean"],"dc:date.accessioned":["2009-09-14T21:24:54Z"],"dc:date.available":["2009-09-14T21:24:54Z"],"dc:date.issued":["2009-09-14T21:24:54Z"],"dc:description.abstract":["Fluid suspended biological particles (bioparticles) flowing through a non-uniform electric field are actuated by the induced dielectrophoretic (DEP) force, known to be dependent upon the bioparticles’ dielectric phenotypes. In this work: a 10-1000 kHz DEP actuation potential applied to a co-planar microelectrode array (MEA) induces a DEP force, altering passing bioparticle trajectories as monitored using: (1) an optical assay, in which the lateral bioparticle velocities are estimated from digital video; and (2) a capacitive cytometer, in which a 1.478 GHz capacitance sensor measures the MEA capacitance perturbations induced by passing bioparticles, which is sensitive to the bioparticles’ elevations. The experimentally observed and simulated lateral velocity profiles of actuated polystyrene microspheres (PSS) and viable and heat shocked Saccharomyces cerevisiae cells verify that the bioparticles’ dielectric phenotypes can be inferred from the resultant trajectories due to the balance between the DEP force and the viscous fluid drag force."],"dc:description.note":["October 2009"],"dc:format.extent":["12090925 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.citation":["Ferrier, G.A., A.N. Hladio, D.J. Thomson, G.E. Bridges, M. Hedayatipoor, S. Olson, and M.R. Freeman (2007). Microfluidic electromanipulation with capacitive detection for cell diagnositc applications, Proc. NSTI 2:214-217.","Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (2008). Capacitance signatures for rapid detection of the polarity of the dielectrophoretic force on single yeast cells, Proc. NSTI 2:589-592.","Ferrier, G.A., A.N. Hladio, D.J. Thomson, G.E. Bridges, M. Hedayatipoor, S. Olson, and M.R. Freeman (2008). Microfluidic electromanipulation with capacitive detection for the mechanical analysis of cells, Biomicrofluidics 2(4-044102):1-13.","Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). A microwave interferometric system for simultaneous actuation and detection of single biological cells, Lab on a Chip.","Ferrier, G.A., S.F. Romanuik, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). Rapid classification of biological cells based on dielectrophoretic actuation with simultaneous capacitive detection, Proc. micro-TAS.","Nikolic-Jaric, M., S.F. Romanuik, G.A. Ferrier, G.E. Bridges, M. Butler, K. Sunley, D.J. Thomson, and M.R. Freeman (2009). Microwave frequency sensor for detection of biological cells in microfluidic channels, Biomicrofluidics 3(3-034103):1-15.","Romanuik, S.F., G.A. Ferrier, D.J. Thomson, G.E. Bridges, S. Olson, and M.R. Freeman (2008). All-electronic detection and actuation of single biological cells for lab-on-a-chip applications, Proc. IEEE Sensors 1:634-637.","Romanuik, S.F., G.A. Ferrier, M.N. Jaric, D.J. Thomson, G.E. Bridges, and M.R. Freeman (Submitted 2009). Dielectrophoretic actuation and simultaneous detection of individual bioparticles, Advances in Biomedical Sensing, Measurements, Instrumentation, and Systems, Eds. A. Lay-Ekuakille and S.C. Mukhopadhyay, Springer – Verlag."],"dc:identifier.uri":["http://hdl.handle.net/1993/3205"],"dc:language.iso":["eng"],"dc:subject":["Microflow","Microfluidic","Cytometer","Cytometry","Dielectrophoretic","Dielectrophoresis","Interferometer","Interferometric","Capacitive Sensor","Capacitance Sensing","Capacitive Detector","Capacitance Detection","Polystyrene","Optical Assay","Electrokinetic","Actuation","Yeast","Saccharomyces cerevisiae","Single-cell Diagnostic","Single-cell Diagnosis","Dielectric modeling","COMSOL","Tracker","Trajectory","Velocity profile","Capacitive Signature","Capacitance Signature","Microelectrode"],"dc:title":["A microflow cytometer with simultaneous dielectrophoretic actuation for the optical assay and capacitive cytometry of individual fluid suspended bioparticles"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:08:57Z"}