{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/32148"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/32148","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Acoustic emission monitoring of damage progression in fiber reinforced polymer rods","abstract":"The fiber reinforced polymer (FRP) bars have been widely used in pre-stressing applications and reinforcing of the civil structures. High strength-to-weight ratio and high resistance to the corrosion make the FRP bars a good replacement for steel reinforcing bars in civil engineering applications. According to the CAN/CSA-S806-12 standard, the maximum recommended stress in FRP bars under service loads should not exceed 25% and 65% of the ultimate strength for glass FRP (GFRP) and carbon FRP (CFRP), respectively. These stress values are set to prevent creep failure in FRP bars. However, for in-service applications, there are few physical indicators that these values have been reached or exceeded. In this work analysis of acoustic emission (AE) signals is used. Two new techniques based on pattern recognition and frequency entropy of the isolated acoustic emission (AE) signal are presented for monitoring damage progression and prediction of failure in FRPs.","abstract_html":"The fiber reinforced polymer (FRP) bars have been widely used in pre-stressing applications and reinforcing of the civil structures. High strength-to-weight ratio and high resistance to the corrosion make the FRP bars a good replacement for steel reinforcing bars in civil engineering applications. According to the CAN/CSA-S806-12 standard, the maximum recommended stress in FRP bars under service loads should not exceed 25% and 65% of the ultimate strength for glass FRP (GFRP) and carbon FRP (CFRP), respectively. These stress values are set to prevent creep failure in FRP bars. However, for in-service applications, there are few physical indicators that these values have been reached or exceeded. In this work analysis of acoustic emission (AE) signals is used. Two new techniques based on pattern recognition and frequency entropy of the isolated acoustic emission (AE) signal are presented for monitoring damage progression and prediction of failure in FRPs.","abstract_has_math":false,"creators":["Shateri, Mohammadhadi"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Thomson, Douglas (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":["Sherif, Sherif (Electrical and Computer Engineering)","Svecova, Dagmar (Civil Engineering)"],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T09:09:00Z","subjects":["Acoustic emission signal","Fiber reinforced polymer rod","Damage monitoring and failure prediction","RMS detection algorithm","Shannon entropy","Fuzzy C-means clustering"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/32148","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/32148","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F32148","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F32148","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sherif, Sherif (Electrical and Computer Engineering)","Svecova, Dagmar (Civil Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Thomson, Douglas (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Shateri, Mohammadhadi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-03-09T15:07:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-03-09T15:07:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Acoustic emission signal","Fiber reinforced polymer rod","Damage monitoring and failure prediction","RMS detection algorithm","Shannon entropy","Fuzzy C-means clustering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/32148"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The fiber reinforced polymer (FRP) bars have been widely used in pre-stressing applications and reinforcing of the civil structures. High strength-to-weight ratio and high resistance to the corrosion make the FRP bars a good replacement for steel reinforcing bars in civil engineering applications. According to the CAN/CSA-S806-12 standard, the maximum recommended stress in FRP bars under service loads should not exceed 25% and 65% of the ultimate strength for glass FRP (GFRP) and carbon FRP (CFRP), respectively. These stress values are set to prevent creep failure in FRP bars. However, for in-service applications, there are few physical indicators that these values have been reached or exceeded. In this work analysis of acoustic emission (AE) signals is used. Two new techniques based on pattern recognition and frequency entropy of the isolated acoustic emission (AE) signal are presented for monitoring damage progression and prediction of failure in FRPs."]},{"key":"dc:description.note","label":"Dc Description Note","values":["May 2017"]},{"key":"dc:title","label":"Title","values":["Acoustic emission monitoring of damage progression in fiber reinforced polymer rods"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Sherif, Sherif (Electrical and Computer Engineering)","Svecova, Dagmar (Civil Engineering)"],"dc:contributor.supervisor":["Thomson, Douglas (Electrical and Computer Engineering)"],"dc:creator":["Shateri, Mohammadhadi"],"dc:date.accessioned":["2017-03-09T15:07:27Z"],"dc:date.available":["2017-03-09T15:07:27Z"],"dc:date.issued":["2017"],"dc:description.abstract":["The fiber reinforced polymer (FRP) bars have been widely used in pre-stressing applications and reinforcing of the civil structures. High strength-to-weight ratio and high resistance to the corrosion make the FRP bars a good replacement for steel reinforcing bars in civil engineering applications. According to the CAN/CSA-S806-12 standard, the maximum recommended stress in FRP bars under service loads should not exceed 25% and 65% of the ultimate strength for glass FRP (GFRP) and carbon FRP (CFRP), respectively. These stress values are set to prevent creep failure in FRP bars. However, for in-service applications, there are few physical indicators that these values have been reached or exceeded. In this work analysis of acoustic emission (AE) signals is used. Two new techniques based on pattern recognition and frequency entropy of the isolated acoustic emission (AE) signal are presented for monitoring damage progression and prediction of failure in FRPs."],"dc:description.note":["May 2017"],"dc:identifier.uri":["http://hdl.handle.net/1993/32148"],"dc:language.iso":["eng"],"dc:subject":["Acoustic emission signal","Fiber reinforced polymer rod","Damage monitoring and failure prediction","RMS detection algorithm","Shannon entropy","Fuzzy C-means clustering"],"dc:title":["Acoustic emission monitoring of damage progression in fiber reinforced polymer rods"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:09:00Z"}