{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/32172"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/32172","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"High frequency model for transient analysis of transformer windings using multiconductor transmission line theory","abstract":"Transients encountered by transformers in power stations during normal operation can have complex oscillatory overvoltages containing a large spectrum of frequency components. These transients can coincide with the natural frequencies of the transformers windings, leading to voltages that can be greater or more severe than the current factory proof tests. This may lead to insulation breakdown and catastrophic failures. Existing lumped parameter RLCG transformer models have been proven to be less accurate for very fast transient overvoltages (VFTO) with frequencies over 1 MHz. A white box model for transient analysis of transformer windings has been developed using Multiconductor Transmission Line (MTL) Theory. This model enables the simulation of natural frequencies of the transformer windings up to frequencies of several MHz, and can be used to compute voltages between turns by representing each turn as a separate transmission line. Both continuous and interleaved disk windings have been modelled and a comparison and validation of the results is presented.","abstract_html":"Transients encountered by transformers in power stations during normal operation can have complex oscillatory overvoltages containing a large spectrum of frequency components. These transients can coincide with the natural frequencies of the transformers windings, leading to voltages that can be greater or more severe than the current factory proof tests. This may lead to insulation breakdown and catastrophic failures. Existing lumped parameter RLCG transformer models have been proven to be less accurate for very fast transient overvoltages (VFTO) with frequencies over 1 MHz. A white box model for transient analysis of transformer windings has been developed using Multiconductor Transmission Line (MTL) Theory. This model enables the simulation of natural frequencies of the transformer windings up to frequencies of several MHz, and can be used to compute voltages between turns by representing each turn as a separate transmission line. Both continuous and interleaved disk windings have been modelled and a comparison and validation of the results is presented.","abstract_has_math":false,"creators":["Fattal, Feras"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Kordi, Behzad (Electrical and Computer Engineering) Ziomek, Waldemar (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":["Gole, Aniruddha (Electrical and Computer Engineering)","Maghoul, Pooneh (Civil Engineering)"],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T09:12:28Z","subjects":["Transformer Modeling","Transformer Transients","Transformer windings","Interleaved","White Box Model","Transformer Testing","Transformer Simulation","Power transformers","Multiconductor Transmission Line Theory","MTL","Finite element method","Transformer Resonance","Frequency domain solution","Time dome solution","Chain parameter"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/32172","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/32172","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F32172","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F32172","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Gole, Aniruddha (Electrical and Computer Engineering)","Maghoul, Pooneh (Civil Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Kordi, Behzad (Electrical and Computer Engineering) Ziomek, Waldemar (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Fattal, Feras"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-03-30T13:36:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-03-30T13:36:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Transformer Modeling","Transformer Transients","Transformer windings","Interleaved","White Box Model","Transformer Testing","Transformer Simulation","Power transformers","Multiconductor Transmission Line Theory","MTL","Finite element method","Transformer Resonance","Frequency domain solution","Time dome solution","Chain parameter"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/32172"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Transients encountered by transformers in power stations during normal operation can have complex oscillatory overvoltages containing a large spectrum of frequency components. These transients can coincide with the natural frequencies of the transformers windings, leading to voltages that can be greater or more severe than the current factory proof tests. This may lead to insulation breakdown and catastrophic failures. Existing lumped parameter RLCG transformer models have been proven to be less accurate for very fast transient overvoltages (VFTO) with frequencies over 1 MHz. A white box model for transient analysis of transformer windings has been developed using Multiconductor Transmission Line (MTL) Theory. This model enables the simulation of natural frequencies of the transformer windings up to frequencies of several MHz, and can be used to compute voltages between turns by representing each turn as a separate transmission line. Both continuous and interleaved disk windings have been modelled and a comparison and validation of the results is presented."]},{"key":"dc:description.note","label":"Dc Description Note","values":["May 2017"]},{"key":"dc:title","label":"Title","values":["High frequency model for transient analysis of transformer windings using multiconductor transmission line theory"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Gole, Aniruddha (Electrical and Computer Engineering)","Maghoul, Pooneh (Civil Engineering)"],"dc:contributor.supervisor":["Kordi, Behzad (Electrical and Computer Engineering) Ziomek, Waldemar (Electrical and Computer Engineering)"],"dc:creator":["Fattal, Feras"],"dc:date.accessioned":["2017-03-30T13:36:27Z"],"dc:date.available":["2017-03-30T13:36:27Z"],"dc:date.issued":["2017"],"dc:description.abstract":["Transients encountered by transformers in power stations during normal operation can have complex oscillatory overvoltages containing a large spectrum of frequency components. These transients can coincide with the natural frequencies of the transformers windings, leading to voltages that can be greater or more severe than the current factory proof tests. This may lead to insulation breakdown and catastrophic failures. Existing lumped parameter RLCG transformer models have been proven to be less accurate for very fast transient overvoltages (VFTO) with frequencies over 1 MHz. A white box model for transient analysis of transformer windings has been developed using Multiconductor Transmission Line (MTL) Theory. This model enables the simulation of natural frequencies of the transformer windings up to frequencies of several MHz, and can be used to compute voltages between turns by representing each turn as a separate transmission line. Both continuous and interleaved disk windings have been modelled and a comparison and validation of the results is presented."],"dc:description.note":["May 2017"],"dc:identifier.uri":["http://hdl.handle.net/1993/32172"],"dc:language.iso":["eng"],"dc:subject":["Transformer Modeling","Transformer Transients","Transformer windings","Interleaved","White Box Model","Transformer Testing","Transformer Simulation","Power transformers","Multiconductor Transmission Line Theory","MTL","Finite element method","Transformer Resonance","Frequency domain solution","Time dome solution","Chain parameter"],"dc:title":["High frequency model for transient analysis of transformer windings using multiconductor transmission line theory"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:12:28Z"}