{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/32405"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/32405","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Punching shear behaviour of GFRP-RC slab-column interior connections with high strength concrete and shear reinforcement","abstract":"This work deals with punching shear behaviour of flat plates reinforced with glass fibre-reinforced polymers (GFRP) reinforcing bars. Six full-scale reinforced concrete (RC) slab-column interior connections were constructed and tested to failure. Two variables were investigated; the flexural reinforcement ratio when high strength concrete (HSC) is used and the type of GFRP shear reinforcement (headed studs and corrugated bars) when normal strength concrete (NSC) is used. All specimens were tested under concentric shear force and unbalanced bending moment with a constant moment-to-shear ratio. Increasing the reinforcement ratio increased punching capacity and post-cracking stiffness for HSC connections. Both types of shear reinforcement increased the punching capacity and deflection of NSC connections. Test results were compared with the predictions of the available fibre-reinforced polymer (FRP) design provisions in North American codes.","abstract_html":"This work deals with punching shear behaviour of flat plates reinforced with glass fibre-reinforced polymers (GFRP) reinforcing bars. Six full-scale reinforced concrete (RC) slab-column interior connections were constructed and tested to failure. Two variables were investigated; the flexural reinforcement ratio when high strength concrete (HSC) is used and the type of GFRP shear reinforcement (headed studs and corrugated bars) when normal strength concrete (NSC) is used. All specimens were tested under concentric shear force and unbalanced bending moment with a constant moment-to-shear ratio. Increasing the reinforcement ratio increased punching capacity and post-cracking stiffness for HSC connections. Both types of shear reinforcement increased the punching capacity and deflection of NSC connections. Test results were compared with the predictions of the available fibre-reinforced polymer (FRP) design provisions in North American codes.","abstract_has_math":false,"creators":["Hussein, Ahmed"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["El-Salakawy, Ehab (Civil Engineering)"],"committee_chairs":[],"committee_members":["Bassuoni, Mohamed (Civil Engineering)","Ojo, Olanrewaju (Mechanical Engineering)"],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T09:05:37Z","subjects":["Interior connections","Shear strength","Shear reinforcement","Headed studs","Glass fiber-reinforced polymers (GFRP)","High strength concrete (HSC)","Flat plate","Slab-column connection","Punching"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/32405","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/32405","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F32405","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F32405","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bassuoni, Mohamed (Civil Engineering)","Ojo, Olanrewaju (Mechanical Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["El-Salakawy, Ehab (Civil Engineering)"]},{"key":"dc:creator","label":"Author","values":["Hussein, Ahmed"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-08-31T16:22:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-08-31T16:22:03Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Interior connections","Shear strength","Shear reinforcement","Headed studs","Glass fiber-reinforced polymers (GFRP)","High strength concrete (HSC)","Flat plate","Slab-column connection","Punching"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/32405"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work deals with punching shear behaviour of flat plates reinforced with glass fibre-reinforced polymers (GFRP) reinforcing bars. Six full-scale reinforced concrete (RC) slab-column interior connections were constructed and tested to failure. Two variables were investigated; the flexural reinforcement ratio when high strength concrete (HSC) is used and the type of GFRP shear reinforcement (headed studs and corrugated bars) when normal strength concrete (NSC) is used. All specimens were tested under concentric shear force and unbalanced bending moment with a constant moment-to-shear ratio. Increasing the reinforcement ratio increased punching capacity and post-cracking stiffness for HSC connections. Both types of shear reinforcement increased the punching capacity and deflection of NSC connections. Test results were compared with the predictions of the available fibre-reinforced polymer (FRP) design provisions in North American codes."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2017"]},{"key":"dc:title","label":"Title","values":["Punching shear behaviour of GFRP-RC slab-column interior connections with high strength concrete and shear reinforcement"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Bassuoni, Mohamed (Civil Engineering)","Ojo, Olanrewaju (Mechanical Engineering)"],"dc:contributor.supervisor":["El-Salakawy, Ehab (Civil Engineering)"],"dc:creator":["Hussein, Ahmed"],"dc:date.accessioned":["2017-08-31T16:22:03Z"],"dc:date.available":["2017-08-31T16:22:03Z"],"dc:date.issued":["2017"],"dc:description.abstract":["This work deals with punching shear behaviour of flat plates reinforced with glass fibre-reinforced polymers (GFRP) reinforcing bars. Six full-scale reinforced concrete (RC) slab-column interior connections were constructed and tested to failure. Two variables were investigated; the flexural reinforcement ratio when high strength concrete (HSC) is used and the type of GFRP shear reinforcement (headed studs and corrugated bars) when normal strength concrete (NSC) is used. All specimens were tested under concentric shear force and unbalanced bending moment with a constant moment-to-shear ratio. Increasing the reinforcement ratio increased punching capacity and post-cracking stiffness for HSC connections. Both types of shear reinforcement increased the punching capacity and deflection of NSC connections. Test results were compared with the predictions of the available fibre-reinforced polymer (FRP) design provisions in North American codes."],"dc:description.note":["October 2017"],"dc:identifier.uri":["http://hdl.handle.net/1993/32405"],"dc:language.iso":["eng"],"dc:subject":["Interior connections","Shear strength","Shear reinforcement","Headed studs","Glass fiber-reinforced polymers (GFRP)","High strength concrete (HSC)","Flat plate","Slab-column connection","Punching"],"dc:title":["Punching shear behaviour of GFRP-RC slab-column interior connections with high strength concrete and shear reinforcement"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:05:37Z"}