{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/33221"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/33221","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Towards a next-generation preclinical PET/MR insert with improved timing and count rate performance","abstract":"Our group has previously developed a PET insert for simultaneous PET/MRI imaging. The insert consists of silicon photomultipliers (SiPMs) with a resistor-based charge division multiplexing readout circuit. Some limitations include a 2.5ns coincidence time resolution (CTR), a relatively long signal duration of >1.5us, and a 1.3us paralyzable dead time. This thesis focuses on characterizing these limitations and demonstrating a second-generation detector module for improved timing and count rate performance. First, optical coupling optimization using acrylic polymer tapes versus conventional silicone optical grease was investigated. Second, CTR and signal duration was reduced by using an enhanced readout board equipped with three new SiPM-type detectors. Last, dead time of the system was reduced by minimizing the sampling number of the OpenPET acquisition system. Future work includes design modification to accommodate the first-generation scintillator footprint and potentially to adapt the OpenPET acquisition system to read in SiPM `fast' outputs.","abstract_html":"Our group has previously developed a PET insert for simultaneous PET/MRI imaging. The insert consists of silicon photomultipliers (SiPMs) with a resistor-based charge division multiplexing readout circuit. Some limitations include a 2.5ns coincidence time resolution (CTR), a relatively long signal duration of &gt;1.5us, and a 1.3us paralyzable dead time. This thesis focuses on characterizing these limitations and demonstrating a second-generation detector module for improved timing and count rate performance. First, optical coupling optimization using acrylic polymer tapes versus conventional silicone optical grease was investigated. Second, CTR and signal duration was reduced by using an enhanced readout board equipped with three new SiPM-type detectors. Last, dead time of the system was reduced by minimizing the sampling number of the OpenPET acquisition system. Future work includes design modification to accommodate the first-generation scintillator footprint and potentially to adapt the OpenPET acquisition system to read in SiPM `fast&#x27; outputs.","abstract_has_math":false,"creators":["Van Elburg, Devin"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Goertzen, Andrew (Physics and Astronomy)"],"committee_chairs":[],"committee_members":["Mammei, Juliette (Physics and Astronomy)","Major, Arkady (Electrical and Computer Engineering)","Ingleby, Harry (Physics and Astronomy)"],"year":2018,"date_issued":"2018-08","date_published":"2018-08","updated_at":"2026-11-19T09:13:53Z","subjects":["Positron emission tomography","Preclinical PET/MR inserts","Coincidence time resolution","Silicon photomultipliers","Multi-pixel photon counters","Dead time"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/33221","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/33221","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F33221","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F33221","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Mammei, Juliette (Physics and Astronomy)","Major, Arkady (Electrical and Computer Engineering)","Ingleby, Harry (Physics and Astronomy)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Goertzen, Andrew (Physics and Astronomy)"]},{"key":"dc:creator","label":"Author","values":["Van Elburg, Devin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-08-22T21:12:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-08-22T21:12:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2018-08-10T16:01:22Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Positron emission tomography","Preclinical PET/MR inserts","Coincidence time resolution","Silicon photomultipliers","Multi-pixel photon counters","Dead time"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/33221"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Our group has previously developed a PET insert for simultaneous PET/MRI imaging. The insert consists of silicon photomultipliers (SiPMs) with a resistor-based charge division multiplexing readout circuit. Some limitations include a 2.5ns coincidence time resolution (CTR), a relatively long signal duration of >1.5us, and a 1.3us paralyzable dead time. This thesis focuses on characterizing these limitations and demonstrating a second-generation detector module for improved timing and count rate performance. First, optical coupling optimization using acrylic polymer tapes versus conventional silicone optical grease was investigated. Second, CTR and signal duration was reduced by using an enhanced readout board equipped with three new SiPM-type detectors. Last, dead time of the system was reduced by minimizing the sampling number of the OpenPET acquisition system. Future work includes design modification to accommodate the first-generation scintillator footprint and potentially to adapt the OpenPET acquisition system to read in SiPM `fast' outputs."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2018"]},{"key":"dc:title","label":"Title","values":["Towards a next-generation preclinical PET/MR insert with improved timing and count rate performance"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Mammei, Juliette (Physics and Astronomy)","Major, Arkady (Electrical and Computer Engineering)","Ingleby, Harry (Physics and Astronomy)"],"dc:contributor.supervisor":["Goertzen, Andrew (Physics and Astronomy)"],"dc:creator":["Van Elburg, Devin"],"dc:date.accessioned":["2018-08-22T21:12:42Z"],"dc:date.available":["2018-08-22T21:12:42Z"],"dc:date.issued":["2018-08"],"dc:date.submitted":["2018-08-10T16:01:22Z"],"dc:description.abstract":["Our group has previously developed a PET insert for simultaneous PET/MRI imaging. The insert consists of silicon photomultipliers (SiPMs) with a resistor-based charge division multiplexing readout circuit. Some limitations include a 2.5ns coincidence time resolution (CTR), a relatively long signal duration of >1.5us, and a 1.3us paralyzable dead time. This thesis focuses on characterizing these limitations and demonstrating a second-generation detector module for improved timing and count rate performance. First, optical coupling optimization using acrylic polymer tapes versus conventional silicone optical grease was investigated. Second, CTR and signal duration was reduced by using an enhanced readout board equipped with three new SiPM-type detectors. Last, dead time of the system was reduced by minimizing the sampling number of the OpenPET acquisition system. Future work includes design modification to accommodate the first-generation scintillator footprint and potentially to adapt the OpenPET acquisition system to read in SiPM `fast' outputs."],"dc:description.note":["October 2018"],"dc:identifier.uri":["http://hdl.handle.net/1993/33221"],"dc:language.iso":["eng"],"dc:subject":["Positron emission tomography","Preclinical PET/MR inserts","Coincidence time resolution","Silicon photomultipliers","Multi-pixel photon counters","Dead time"],"dc:title":["Towards a next-generation preclinical PET/MR insert with improved timing and count rate performance"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:13:53Z"}