{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/33604"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/33604","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Assessing Right-Hand Coiled Coil (RHCC) Protein as a Potential new passive sampler matrix for binding polycyclic aromatic hydrocarbons (PAHs)","abstract":"A field study tested the ability of a protein, Right-Handed Coiled-Coil (RHCC), to bind polycyclic aromatic hydrocarbons (PAHs) in aquatic environments. The usefulness of RHCC as a sampling matrix for a new passive sampling device was compared to a traditional semi-permeable membrane device (SPMD) matrix. Mesocosms were treated with diluted bitumen and RHCC did not bind PAHs as efficiently as the SPMD. The study did however, determine that RHCC has the capability to bind some smaller PAHs. It is still unknown if RHCC binds these smaller PAHs more quickly than SPMDs. A positive, but insignificant relationship between [PAHs] in fish and RHCC was observed. The same comparison between [PAHs] in fish and SPMDs was negative. No significant relationships were observed among [PAHs] in water, sediment, or between the two passive samplers. RHCC has the capabilities of a promising PSD for small PAHs with more studies required to confirm its usefulness.","abstract_html":"A field study tested the ability of a protein, Right-Handed Coiled-Coil (RHCC), to bind polycyclic aromatic hydrocarbons (PAHs) in aquatic environments. The usefulness of RHCC as a sampling matrix for a new passive sampling device was compared to a traditional semi-permeable membrane device (SPMD) matrix. Mesocosms were treated with diluted bitumen and RHCC did not bind PAHs as efficiently as the SPMD. The study did however, determine that RHCC has the capability to bind some smaller PAHs. It is still unknown if RHCC binds these smaller PAHs more quickly than SPMDs. A positive, but insignificant relationship between [PAHs] in fish and RHCC was observed. The same comparison between [PAHs] in fish and SPMDs was negative. No significant relationships were observed among [PAHs] in water, sediment, or between the two passive samplers. RHCC has the capabilities of a promising PSD for small PAHs with more studies required to confirm its usefulness.","abstract_has_math":false,"creators":["Leslie, Jennifer"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Environment and Geography","degree_department":null,"school":null,"contributors":[],"advisors":["Palace, Vince (Environment and Geography) Hanson, Mark (Environment and Geography)"],"committee_chairs":[],"committee_members":["Loseto, Lisa (Environment and Geography)","Tomy, Gregg (Chemistry)"],"year":2018,"date_issued":"2018-11-22","date_published":"2018-11-22","updated_at":"2026-11-19T09:06:19Z","subjects":["PAHs","RHCC","Diluted bitumen","Passive samper","Protein","Oil spill","Freshwater","Fish","Field study"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["APA"],"render_values":[{"text":"APA","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/33604","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/33604","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F33604","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F33604","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Loseto, Lisa (Environment and Geography)","Tomy, Gregg (Chemistry)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Palace, Vince (Environment and Geography) Hanson, Mark (Environment and Geography)"]},{"key":"dc:creator","label":"Author","values":["Leslie, Jennifer"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-12-20T18:55:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-12-20T18:55:08Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-11-22"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2018-12-05T17:02:21Z","2018-12-19T18:39:37Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environment and Geography"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["PAHs","RHCC","Diluted bitumen","Passive samper","Protein","Oil spill","Freshwater","Fish","Field study"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["APA"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/33604"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A field study tested the ability of a protein, Right-Handed Coiled-Coil (RHCC), to bind polycyclic aromatic hydrocarbons (PAHs) in aquatic environments. The usefulness of RHCC as a sampling matrix for a new passive sampling device was compared to a traditional semi-permeable membrane device (SPMD) matrix. Mesocosms were treated with diluted bitumen and RHCC did not bind PAHs as efficiently as the SPMD. The study did however, determine that RHCC has the capability to bind some smaller PAHs. It is still unknown if RHCC binds these smaller PAHs more quickly than SPMDs. A positive, but insignificant relationship between [PAHs] in fish and RHCC was observed. The same comparison between [PAHs] in fish and SPMDs was negative. No significant relationships were observed among [PAHs] in water, sediment, or between the two passive samplers. RHCC has the capabilities of a promising PSD for small PAHs with more studies required to confirm its usefulness."]},{"key":"dc:description.note","label":"Dc Description Note","values":["February 2019"]},{"key":"dc:title","label":"Title","values":["Assessing Right-Hand Coiled Coil (RHCC) Protein as a Potential new passive sampler matrix for binding polycyclic aromatic hydrocarbons (PAHs)"]},{"key":"local:admin","label":"Local Admin","values":["yes"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Loseto, Lisa (Environment and Geography)","Tomy, Gregg (Chemistry)"],"dc:contributor.supervisor":["Palace, Vince (Environment and Geography) Hanson, Mark (Environment and Geography)"],"dc:creator":["Leslie, Jennifer"],"dc:date.accessioned":["2018-12-20T18:55:08Z"],"dc:date.available":["2018-12-20T18:55:08Z"],"dc:date.issued":["2018-11-22"],"dc:date.submitted":["2018-12-05T17:02:21Z","2018-12-19T18:39:37Z"],"dc:description.abstract":["A field study tested the ability of a protein, Right-Handed Coiled-Coil (RHCC), to bind polycyclic aromatic hydrocarbons (PAHs) in aquatic environments. The usefulness of RHCC as a sampling matrix for a new passive sampling device was compared to a traditional semi-permeable membrane device (SPMD) matrix. Mesocosms were treated with diluted bitumen and RHCC did not bind PAHs as efficiently as the SPMD. The study did however, determine that RHCC has the capability to bind some smaller PAHs. It is still unknown if RHCC binds these smaller PAHs more quickly than SPMDs. A positive, but insignificant relationship between [PAHs] in fish and RHCC was observed. The same comparison between [PAHs] in fish and SPMDs was negative. No significant relationships were observed among [PAHs] in water, sediment, or between the two passive samplers. RHCC has the capabilities of a promising PSD for small PAHs with more studies required to confirm its usefulness."],"dc:description.note":["February 2019"],"dc:identifier.citation":["APA"],"dc:identifier.uri":["http://hdl.handle.net/1993/33604"],"dc:language.iso":["eng"],"dc:subject":["PAHs","RHCC","Diluted bitumen","Passive samper","Protein","Oil spill","Freshwater","Fish","Field study"],"dc:title":["Assessing Right-Hand Coiled Coil (RHCC) Protein as a Potential new passive sampler matrix for binding polycyclic aromatic hydrocarbons (PAHs)"],"dc:type":["master thesis"],"local:admin":["yes"],"others:access_status":["open.access"],"thesis:degree_discipline":["Environment and Geography"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:06:19Z"}