{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/33655"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/33655","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Highly sensitive Rb magnetometer for neutron electric dipole moment experiments","abstract":"A non-zero neutron electric dipole moment (nEDM) would indicate time-reversal and charge-parity violation. Our collaboration is developing an experiment at TRIUMF to improve the sensitivity to the nEDM by one order of magnitude ($10^{-27}$~e$\\cdot$cm). I developed a highly sensitive magnetometer based on nonlinear magneto-optical rotation (NMOR) in Rb vapour. In the future such magnetometers will serve in an array to form an auxiliary magnetometer system monitoring the stability and uniformity of the magnetic field in the nEDM experiment. The operation of the magnetometer in a free-induction-decay mode was the focus of this thesis. The precision of the field measurement, drifts over time, the impact of degaussing, and measurements of transverse fields were studied using the magnetometer.","abstract_html":"A non-zero neutron electric dipole moment (nEDM) would indicate time-reversal and charge-parity violation. Our collaboration is developing an experiment at TRIUMF to improve the sensitivity to the nEDM by one order of magnitude (<span class=\"etd-inline-math\">10<sup>-27</sup></span>~e$\\cdot$cm). I developed a highly sensitive magnetometer based on nonlinear magneto-optical rotation (NMOR) in Rb vapour. In the future such magnetometers will serve in an array to form an auxiliary magnetometer system monitoring the stability and uniformity of the magnetic field in the nEDM experiment. The operation of the magnetometer in a free-induction-decay mode was the focus of this thesis. The precision of the field measurement, drifts over time, the impact of degaussing, and measurements of transverse fields were studied using the magnetometer.","abstract_has_math":true,"creators":["Das, Moushumi Jr"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Martin, Jeff (Physics and Astronomy)"],"committee_chairs":[],"committee_members":["Gwinner, Gerald (Physics and Astronomy)","Thomson, Douglas (Electrical and Computer Engineering)"],"year":2018,"date_issued":"2018-12-13","date_published":"2018-12-13","updated_at":"2026-11-19T09:12:04Z","subjects":["Neutron electric dipole moment"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/33655","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/33655","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F33655","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F33655","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Gwinner, Gerald (Physics and Astronomy)","Thomson, Douglas (Electrical and Computer Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Martin, Jeff (Physics and Astronomy)"]},{"key":"dc:creator","label":"Author","values":["Das, Moushumi Jr"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-01-08T18:18:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-08T18:18:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-12-13"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2019-01-03T15:12:17Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neutron electric dipole moment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/33655"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A non-zero neutron electric dipole moment (nEDM) would indicate time-reversal and charge-parity violation. Our collaboration is developing an experiment at TRIUMF to improve the sensitivity to the nEDM by one order of magnitude ($10^{-27}$~e$\\cdot$cm). I developed a highly sensitive magnetometer based on nonlinear magneto-optical rotation (NMOR) in Rb vapour. In the future such magnetometers will serve in an array to form an auxiliary magnetometer system monitoring the stability and uniformity of the magnetic field in the nEDM experiment. The operation of the magnetometer in a free-induction-decay mode was the focus of this thesis. The precision of the field measurement, drifts over time, the impact of degaussing, and measurements of transverse fields were studied using the magnetometer."]},{"key":"dc:description.note","label":"Dc Description Note","values":["February 2019"]},{"key":"dc:title","label":"Title","values":["Highly sensitive Rb magnetometer for neutron electric dipole moment experiments"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Gwinner, Gerald (Physics and Astronomy)","Thomson, Douglas (Electrical and Computer Engineering)"],"dc:contributor.supervisor":["Martin, Jeff (Physics and Astronomy)"],"dc:creator":["Das, Moushumi Jr"],"dc:date.accessioned":["2019-01-08T18:18:56Z"],"dc:date.available":["2019-01-08T18:18:56Z"],"dc:date.issued":["2018-12-13"],"dc:date.submitted":["2019-01-03T15:12:17Z"],"dc:description.abstract":["A non-zero neutron electric dipole moment (nEDM) would indicate time-reversal and charge-parity violation. Our collaboration is developing an experiment at TRIUMF to improve the sensitivity to the nEDM by one order of magnitude ($10^{-27}$~e$\\cdot$cm). I developed a highly sensitive magnetometer based on nonlinear magneto-optical rotation (NMOR) in Rb vapour. In the future such magnetometers will serve in an array to form an auxiliary magnetometer system monitoring the stability and uniformity of the magnetic field in the nEDM experiment. The operation of the magnetometer in a free-induction-decay mode was the focus of this thesis. The precision of the field measurement, drifts over time, the impact of degaussing, and measurements of transverse fields were studied using the magnetometer."],"dc:description.note":["February 2019"],"dc:identifier.uri":["http://hdl.handle.net/1993/33655"],"dc:language.iso":["eng"],"dc:subject":["Neutron electric dipole moment"],"dc:title":["Highly sensitive Rb magnetometer for neutron electric dipole moment experiments"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:12:04Z"}