{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/34064"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/34064","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Development of a continuous flow reactor for aerobic granular sludge","abstract":"Aerobic granular sludge is an advanced biological process that provides sustainable wastewater treatment. Compared to conventional wastewater treatment processes, aerobic granular sludge exhibits better settling, higher volumetric loading, reduced chemical and electrical requirements, and less biosolids production. Currently, aerobic granular sludge is only available as a sequencing batch reactor process. Sequencing batch reactors, however, would not be suitable for retrofit at most existing wastewater treatment facilities. Therefore, many facilities would not be able to realize the benefits of aerobic granular sludge unless significant changes to existing infrastructure were made. A more compatible technology, being a continuous flow reactor, would facilitate the implementation of aerobic granular sludge into existing facilities that would otherwise struggle with sequencing batch reactors. Thus, the goal of these studies was to develop a continuous flow reactor for aerobic granular sludge that would be suitable for retrofit into existing wastewater treatment facilities. To attain the goal, several items had to be addressed, including: 1) the suitability of aerobic granular sludge to treat low-strength, municipal wastewater; 2) the importance of hydrodynamic shear force for aerobic granular sludge stability; 3) the role of organic loading rate on aerobic granular sludge stability and performance; 4) the impact of selective wasting on granulation in continuous flow; and 5) the impact of reactor configuration on granulation in continuous flow. For more general items, such as suitability for low-strength wastewater and the role of hydrodynamic shear force, lab-scale sequencing batch reactors were used. The remaining tests were carried out in lab- and pilot-scale continuous flow reactors. Based on the results, design and operational parameters for an aerobic granular sludge-continuous flow reactor were developed and confirmed to be feasible for the treatment of low-strength, municipal wastewater.","abstract_html":"Aerobic granular sludge is an advanced biological process that provides sustainable wastewater treatment. Compared to conventional wastewater treatment processes, aerobic granular sludge exhibits better settling, higher volumetric loading, reduced chemical and electrical requirements, and less biosolids production. Currently, aerobic granular sludge is only available as a sequencing batch reactor process. Sequencing batch reactors, however, would not be suitable for retrofit at most existing wastewater treatment facilities. Therefore, many facilities would not be able to realize the benefits of aerobic granular sludge unless significant changes to existing infrastructure were made. A more compatible technology, being a continuous flow reactor, would facilitate the implementation of aerobic granular sludge into existing facilities that would otherwise struggle with sequencing batch reactors. Thus, the goal of these studies was to develop a continuous flow reactor for aerobic granular sludge that would be suitable for retrofit into existing wastewater treatment facilities. To attain the goal, several items had to be addressed, including: 1) the suitability of aerobic granular sludge to treat low-strength, municipal wastewater; 2) the importance of hydrodynamic shear force for aerobic granular sludge stability; 3) the role of organic loading rate on aerobic granular sludge stability and performance; 4) the impact of selective wasting on granulation in continuous flow; and 5) the impact of reactor configuration on granulation in continuous flow. For more general items, such as suitability for low-strength wastewater and the role of hydrodynamic shear force, lab-scale sequencing batch reactors were used. The remaining tests were carried out in lab- and pilot-scale continuous flow reactors. Based on the results, design and operational parameters for an aerobic granular sludge-continuous flow reactor were developed and confirmed to be feasible for the treatment of low-strength, municipal wastewater.","abstract_has_math":false,"creators":["Devlin, Tanner"],"institution":null,"degree_name":null,"degree_level":"Doctor of Philosophy (Ph.D.)","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Oleszkiewicz, Jan (Civil Engineering)"],"committee_chairs":[],"committee_members":["Sears, Keith (Civil Engineering)","Sparling, Richard (Microbiology)","Murthy, Sudhir (Earth and Environmental Engineering, Columbia University)"],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T09:08:23Z","subjects":["Aerobic granular sludge","Continuous flow","Wastewater treatment"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Devlin, T. R., & Oleszkiewicz, J. A. (2018). Cultivation of aerobic granular sludge in continuous flow under various selective pressure. Bioresource Technology, 253, 281–287. https://doi.org/10.1016/j.biortech.2018.01.056","Devlin, T. R., di Biase, A., Kowalski, M., & Oleszkiewicz, J. A. (2017). Granulation of activated sludge under low hydrodynamic shear and different wastewater characteristics. Bioresource Technology, 224, 229–235. https://doi.org/10.1016/j.biortech.2016.11.005","Devlin, T., Kowalski, M., Di Biase, A., & Oleszkiewicz, J. (2018). Kinetics of aerobic granular sludge treating low-strength synthetic wastewater at high dissolved oxygen. Environmental Technology, 1–9. https://doi.org/10.1080/09593330.2018.1538258","Corsino, S., Di Biase, A., Devlin, T., Munz, G., Torregrossa, M., & Oleszkiewicz, J. (2017). Effect of extended famine conditions on aerobic granular sludge stability in the treatment of brewery wastewater. Bioresource Technology, 226, 150–157. https://doi.org/10.1016/j.biortech.2016.12.026"],"render_values":[{"text":"Devlin, T. R., & Oleszkiewicz, J. A. (2018). Cultivation of aerobic granular sludge in continuous flow under various selective pressure. Bioresource Technology, 253, 281–287. https://doi.org/10.1016/j.biortech.2018.01.056","href":"https://doi.org/10.1016/j.biortech.2018.01.056","code":true},{"text":"Devlin, T. R., di Biase, A., Kowalski, M., & Oleszkiewicz, J. A. (2017). Granulation of activated sludge under low hydrodynamic shear and different wastewater characteristics. Bioresource Technology, 224, 229–235. https://doi.org/10.1016/j.biortech.2016.11.005","href":"https://doi.org/10.1016/j.biortech.2016.11.005","code":true},{"text":"Devlin, T., Kowalski, M., Di Biase, A., & Oleszkiewicz, J. (2018). Kinetics of aerobic granular sludge treating low-strength synthetic wastewater at high dissolved oxygen. Environmental Technology, 1–9. https://doi.org/10.1080/09593330.2018.1538258","href":"https://doi.org/10.1080/09593330.2018.1538258","code":true},{"text":"Corsino, S., Di Biase, A., Devlin, T., Munz, G., Torregrossa, M., & Oleszkiewicz, J. (2017). Effect of extended famine conditions on aerobic granular sludge stability in the treatment of brewery wastewater. Bioresource Technology, 226, 150–157. https://doi.org/10.1016/j.biortech.2016.12.026","href":"https://doi.org/10.1016/j.biortech.2016.12.026","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/34064","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/34064","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F34064","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F34064","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sears, Keith (Civil Engineering)","Sparling, Richard (Microbiology)","Murthy, Sudhir (Earth and Environmental Engineering, Columbia University)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Oleszkiewicz, Jan (Civil Engineering)"]},{"key":"dc:creator","label":"Author","values":["Devlin, Tanner"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-08-06T20:52:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-06T20:52:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2019-07-21T15:14:41Z"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aerobic granular sludge","Continuous flow","Wastewater treatment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Devlin, T. R., & Oleszkiewicz, J. A. (2018). Cultivation of aerobic granular sludge in continuous flow under various selective pressure. Bioresource Technology, 253, 281–287. https://doi.org/10.1016/j.biortech.2018.01.056","Devlin, T. R., di Biase, A., Kowalski, M., & Oleszkiewicz, J. A. (2017). Granulation of activated sludge under low hydrodynamic shear and different wastewater characteristics. Bioresource Technology, 224, 229–235. https://doi.org/10.1016/j.biortech.2016.11.005","Devlin, T., Kowalski, M., Di Biase, A., & Oleszkiewicz, J. (2018). Kinetics of aerobic granular sludge treating low-strength synthetic wastewater at high dissolved oxygen. Environmental Technology, 1–9. https://doi.org/10.1080/09593330.2018.1538258","Corsino, S., Di Biase, A., Devlin, T., Munz, G., Torregrossa, M., & Oleszkiewicz, J. (2017). Effect of extended famine conditions on aerobic granular sludge stability in the treatment of brewery wastewater. Bioresource Technology, 226, 150–157. https://doi.org/10.1016/j.biortech.2016.12.026"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/34064"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Aerobic granular sludge is an advanced biological process that provides sustainable wastewater treatment. Compared to conventional wastewater treatment processes, aerobic granular sludge exhibits better settling, higher volumetric loading, reduced chemical and electrical requirements, and less biosolids production. Currently, aerobic granular sludge is only available as a sequencing batch reactor process. Sequencing batch reactors, however, would not be suitable for retrofit at most existing wastewater treatment facilities. Therefore, many facilities would not be able to realize the benefits of aerobic granular sludge unless significant changes to existing infrastructure were made. A more compatible technology, being a continuous flow reactor, would facilitate the implementation of aerobic granular sludge into existing facilities that would otherwise struggle with sequencing batch reactors. Thus, the goal of these studies was to develop a continuous flow reactor for aerobic granular sludge that would be suitable for retrofit into existing wastewater treatment facilities. To attain the goal, several items had to be addressed, including: 1) the suitability of aerobic granular sludge to treat low-strength, municipal wastewater; 2) the importance of hydrodynamic shear force for aerobic granular sludge stability; 3) the role of organic loading rate on aerobic granular sludge stability and performance; 4) the impact of selective wasting on granulation in continuous flow; and 5) the impact of reactor configuration on granulation in continuous flow. For more general items, such as suitability for low-strength wastewater and the role of hydrodynamic shear force, lab-scale sequencing batch reactors were used. The remaining tests were carried out in lab- and pilot-scale continuous flow reactors. Based on the results, design and operational parameters for an aerobic granular sludge-continuous flow reactor were developed and confirmed to be feasible for the treatment of low-strength, municipal wastewater."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2019"]},{"key":"dc:title","label":"Title","values":["Development of a continuous flow reactor for aerobic granular sludge"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Sears, Keith (Civil Engineering)","Sparling, Richard (Microbiology)","Murthy, Sudhir (Earth and Environmental Engineering, Columbia University)"],"dc:contributor.supervisor":["Oleszkiewicz, Jan (Civil Engineering)"],"dc:creator":["Devlin, Tanner"],"dc:date.accessioned":["2019-08-06T20:52:56Z"],"dc:date.available":["2019-08-06T20:52:56Z"],"dc:date.issued":["2019"],"dc:date.submitted":["2019-07-21T15:14:41Z"],"dc:description.abstract":["Aerobic granular sludge is an advanced biological process that provides sustainable wastewater treatment. Compared to conventional wastewater treatment processes, aerobic granular sludge exhibits better settling, higher volumetric loading, reduced chemical and electrical requirements, and less biosolids production. Currently, aerobic granular sludge is only available as a sequencing batch reactor process. Sequencing batch reactors, however, would not be suitable for retrofit at most existing wastewater treatment facilities. Therefore, many facilities would not be able to realize the benefits of aerobic granular sludge unless significant changes to existing infrastructure were made. A more compatible technology, being a continuous flow reactor, would facilitate the implementation of aerobic granular sludge into existing facilities that would otherwise struggle with sequencing batch reactors. Thus, the goal of these studies was to develop a continuous flow reactor for aerobic granular sludge that would be suitable for retrofit into existing wastewater treatment facilities. To attain the goal, several items had to be addressed, including: 1) the suitability of aerobic granular sludge to treat low-strength, municipal wastewater; 2) the importance of hydrodynamic shear force for aerobic granular sludge stability; 3) the role of organic loading rate on aerobic granular sludge stability and performance; 4) the impact of selective wasting on granulation in continuous flow; and 5) the impact of reactor configuration on granulation in continuous flow. For more general items, such as suitability for low-strength wastewater and the role of hydrodynamic shear force, lab-scale sequencing batch reactors were used. The remaining tests were carried out in lab- and pilot-scale continuous flow reactors. Based on the results, design and operational parameters for an aerobic granular sludge-continuous flow reactor were developed and confirmed to be feasible for the treatment of low-strength, municipal wastewater."],"dc:description.note":["October 2019"],"dc:identifier.citation":["Devlin, T. R., & Oleszkiewicz, J. A. (2018). Cultivation of aerobic granular sludge in continuous flow under various selective pressure. Bioresource Technology, 253, 281–287. https://doi.org/10.1016/j.biortech.2018.01.056","Devlin, T. R., di Biase, A., Kowalski, M., & Oleszkiewicz, J. A. (2017). Granulation of activated sludge under low hydrodynamic shear and different wastewater characteristics. Bioresource Technology, 224, 229–235. https://doi.org/10.1016/j.biortech.2016.11.005","Devlin, T., Kowalski, M., Di Biase, A., & Oleszkiewicz, J. (2018). Kinetics of aerobic granular sludge treating low-strength synthetic wastewater at high dissolved oxygen. Environmental Technology, 1–9. https://doi.org/10.1080/09593330.2018.1538258","Corsino, S., Di Biase, A., Devlin, T., Munz, G., Torregrossa, M., & Oleszkiewicz, J. (2017). Effect of extended famine conditions on aerobic granular sludge stability in the treatment of brewery wastewater. Bioresource Technology, 226, 150–157. https://doi.org/10.1016/j.biortech.2016.12.026"],"dc:identifier.uri":["http://hdl.handle.net/1993/34064"],"dc:language.iso":["eng"],"dc:subject":["Aerobic granular sludge","Continuous flow","Wastewater treatment"],"dc:title":["Development of a continuous flow reactor for aerobic granular sludge"],"dc:type":["doctoral thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T09:08:23Z"}