{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/34095"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/34095","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Statistical system identification and classification using Laguerre functions","abstract":"This research focuses on developing classification methods to automatically identify partial discharge (PD) signals from multiple sources and developing new system identification techniques to help increase the accuracy of these classifications. We use a Laguerre functional basis to approximate PD signal waveforms, obtained through a lab experiment. To perform the approximation, we considered multiple approaches, such as using objective functional methods and a deterministic method. In the process of signal approximation, we developed methods of selecting a proper scaling factor for Laguerre functions. We evaluated the use of the Laguerre basis expansion coefficients to classify PD signals into their respective sources. Linear discriminant analysis (LDA), quadratic discriminant analysis (QDA) and support vector machines (SVM) were used as classifiers in this analysis. It was observed that these methods can classify partial discharge signals with high accuracies, even when the signals are visually indistinguishable. We also developed two methods for system identification, based on a deterministic approach in the form of a recursive formula and a stochastic method based on a group Lasso model. The aim of system identification was to improve the classification accuracies by removing the effect of the system from the observed PD waveforms. Through numerical evaluations we showed that there are situations where classification after system identification can improve classification accuracies.","abstract_html":"This research focuses on developing classification methods to automatically identify partial discharge (PD) signals from multiple sources and developing new system identification techniques to help increase the accuracy of these classifications. We use a Laguerre functional basis to approximate PD signal waveforms, obtained through a lab experiment. To perform the approximation, we considered multiple approaches, such as using objective functional methods and a deterministic method. In the process of signal approximation, we developed methods of selecting a proper scaling factor for Laguerre functions. We evaluated the use of the Laguerre basis expansion coefficients to classify PD signals into their respective sources. Linear discriminant analysis (LDA), quadratic discriminant analysis (QDA) and support vector machines (SVM) were used as classifiers in this analysis. It was observed that these methods can classify partial discharge signals with high accuracies, even when the signals are visually indistinguishable. We also developed two methods for system identification, based on a deterministic approach in the form of a recursive formula and a stochastic method based on a group Lasso model. The aim of system identification was to improve the classification accuracies by removing the effect of the system from the observed PD waveforms. Through numerical evaluations we showed that there are situations where classification after system identification can improve classification accuracies.","abstract_has_math":false,"creators":["Jayasinghe, Pramoda"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Statistics","degree_department":null,"school":null,"contributors":[],"advisors":["Jafari Jozani, Mohammad (Statistics) Kordi, Behzad (Electrical & Computer Engineering)"],"committee_chairs":[],"committee_members":["Leblanc, Alexandre (Statistics)","Muthukumarana, Saman (Statistics)"],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T09:11:18Z","subjects":["Statistical learning","Classification","Partial discharge","System identification"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/34095","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/34095","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F34095","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F34095","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Leblanc, Alexandre (Statistics)","Muthukumarana, Saman (Statistics)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Jafari Jozani, Mohammad (Statistics) Kordi, Behzad (Electrical & Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Jayasinghe, Pramoda"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-08-26T21:15:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-08-26T21:15:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2019-08-20T06:00:47Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Statistics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Statistical learning","Classification","Partial discharge","System identification"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/34095"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research focuses on developing classification methods to automatically identify partial discharge (PD) signals from multiple sources and developing new system identification techniques to help increase the accuracy of these classifications. We use a Laguerre functional basis to approximate PD signal waveforms, obtained through a lab experiment. To perform the approximation, we considered multiple approaches, such as using objective functional methods and a deterministic method. In the process of signal approximation, we developed methods of selecting a proper scaling factor for Laguerre functions. We evaluated the use of the Laguerre basis expansion coefficients to classify PD signals into their respective sources. Linear discriminant analysis (LDA), quadratic discriminant analysis (QDA) and support vector machines (SVM) were used as classifiers in this analysis. It was observed that these methods can classify partial discharge signals with high accuracies, even when the signals are visually indistinguishable. We also developed two methods for system identification, based on a deterministic approach in the form of a recursive formula and a stochastic method based on a group Lasso model. The aim of system identification was to improve the classification accuracies by removing the effect of the system from the observed PD waveforms. Through numerical evaluations we showed that there are situations where classification after system identification can improve classification accuracies."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2019"]},{"key":"dc:title","label":"Title","values":["Statistical system identification and classification using Laguerre functions"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Leblanc, Alexandre (Statistics)","Muthukumarana, Saman (Statistics)"],"dc:contributor.supervisor":["Jafari Jozani, Mohammad (Statistics) Kordi, Behzad (Electrical & Computer Engineering)"],"dc:creator":["Jayasinghe, Pramoda"],"dc:date.accessioned":["2019-08-26T21:15:41Z"],"dc:date.available":["2019-08-26T21:15:41Z"],"dc:date.issued":["2019"],"dc:date.submitted":["2019-08-20T06:00:47Z"],"dc:description.abstract":["This research focuses on developing classification methods to automatically identify partial discharge (PD) signals from multiple sources and developing new system identification techniques to help increase the accuracy of these classifications. We use a Laguerre functional basis to approximate PD signal waveforms, obtained through a lab experiment. To perform the approximation, we considered multiple approaches, such as using objective functional methods and a deterministic method. In the process of signal approximation, we developed methods of selecting a proper scaling factor for Laguerre functions. We evaluated the use of the Laguerre basis expansion coefficients to classify PD signals into their respective sources. Linear discriminant analysis (LDA), quadratic discriminant analysis (QDA) and support vector machines (SVM) were used as classifiers in this analysis. It was observed that these methods can classify partial discharge signals with high accuracies, even when the signals are visually indistinguishable. We also developed two methods for system identification, based on a deterministic approach in the form of a recursive formula and a stochastic method based on a group Lasso model. The aim of system identification was to improve the classification accuracies by removing the effect of the system from the observed PD waveforms. Through numerical evaluations we showed that there are situations where classification after system identification can improve classification accuracies."],"dc:description.note":["October 2019"],"dc:identifier.uri":["http://hdl.handle.net/1993/34095"],"dc:language.iso":["eng"],"dc:subject":["Statistical learning","Classification","Partial discharge","System identification"],"dc:title":["Statistical system identification and classification using Laguerre functions"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Statistics"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:11:18Z"}