{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/34197"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/34197","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Validity and comparison between 2D (normal photo) and 3dMD (3D image) in orthodontic diagnosis","abstract":"Objective: The aim was to evaluate the validity and comparison between direct anthropometry measurements as the “Gold Standard” with 2D-images (Normal Photo) and 3D-images (3dMD) as a new contemporary tool for orthodontic diagnosis. Methods & Materials: 51 subjects (22 Male and 29 Female) were randomly selected, without facial deformity, surgery or facial hair. Eight anatomical landmarks were selected and plotted on the face to create 7 linear and 4 angular measurements which were measured directly (D) by a digital caliper and a protractor (www.examobile.com). Photos (2D) were taken with a Nikon DSLR camera and ring flash in NHP as well as a 3D-image with the 3dMD system (Atlanta, Georgia, USA). Both 2D photos and 3D images were analyzed by Tracker (www.opensourcephysics.org/Douglas Brown) and Vultus software for the same linear and angular parameters measured for each subject, respectively. 10% of the samples (5 cases) were randomly re-measured for intra-observer reproducibility. Collected data were analyzed by SAS using the paired t-test to compare the validity of direct (D), 2D and 3D measurements. Results: The results show no statistically significant difference between the direct measurement group (D) and 3D measurements. (p > 0.05) but a highly statistically significant difference is evident between the direct measurement group (D) and 2D measurements. (p < 0.01) The 2D and 3D measurement groups also showed a statistically significant difference.(p < 0.05) Conclusion: ➤ This study has validated the accuracy of 3D measurements versus direct measurement. ➤ 3D measurement techniques are more accurate, almost by 1mm in linear and up to 1 degree in angular measurements, than 2D techniques.","abstract_html":"Objective: The aim was to evaluate the validity and comparison between direct anthropometry measurements as the “Gold Standard” with 2D-images (Normal Photo) and 3D-images (3dMD) as a new contemporary tool for orthodontic diagnosis. Methods &amp; Materials: 51 subjects (22 Male and 29 Female) were randomly selected, without facial deformity, surgery or facial hair. Eight anatomical landmarks were selected and plotted on the face to create 7 linear and 4 angular measurements which were measured directly (D) by a digital caliper and a protractor (www.examobile.com). Photos (2D) were taken with a Nikon DSLR camera and ring flash in NHP as well as a 3D-image with the 3dMD system (Atlanta, Georgia, USA). Both 2D photos and 3D images were analyzed by Tracker (www.opensourcephysics.org/Douglas Brown) and Vultus software for the same linear and angular parameters measured for each subject, respectively. 10% of the samples (5 cases) were randomly re-measured for intra-observer reproducibility. Collected data were analyzed by SAS using the paired t-test to compare the validity of direct (D), 2D and 3D measurements. Results: The results show no statistically significant difference between the direct measurement group (D) and 3D measurements. (p &gt; 0.05) but a highly statistically significant difference is evident between the direct measurement group (D) and 2D measurements. (p &lt; 0.01) The 2D and 3D measurement groups also showed a statistically significant difference.(p &lt; 0.05) Conclusion: ➤ This study has validated the accuracy of 3D measurements versus direct measurement. ➤ 3D measurement techniques are more accurate, almost by 1mm in linear and up to 1 degree in angular measurements, than 2D techniques.","abstract_has_math":false,"creators":["Neishaboory, Amin"],"institution":null,"degree_name":null,"degree_level":"Master of Dentistry (M.Dent.)","degree_discipline":"Preventive Dental Science","degree_department":null,"school":null,"contributors":[],"advisors":["Drummond, Robert (Preventive Dental Science) Wiltshire, William (Preventive Dental Science)"],"committee_chairs":[],"committee_members":["Vint, Kevin (Preventive Dental Science)","Shah, Adnan (Dental Diagnostic and Surgical Sciences)"],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T09:03:34Z","subjects":["Facial diagnostic in orthodontics"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/34197","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/34197","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F34197","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F34197","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Vint, Kevin (Preventive Dental Science)","Shah, Adnan (Dental Diagnostic and Surgical Sciences)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Drummond, Robert (Preventive Dental Science) Wiltshire, William (Preventive Dental Science)"]},{"key":"dc:creator","label":"Author","values":["Neishaboory, Amin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-09-10T20:23:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-09-10T20:23:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2019-08-29T17:44:49Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Preventive Dental Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Dentistry (M.Dent.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Facial diagnostic in orthodontics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/34197"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Objective: The aim was to evaluate the validity and comparison between direct anthropometry measurements as the “Gold Standard” with 2D-images (Normal Photo) and 3D-images (3dMD) as a new contemporary tool for orthodontic diagnosis. Methods & Materials: 51 subjects (22 Male and 29 Female) were randomly selected, without facial deformity, surgery or facial hair. Eight anatomical landmarks were selected and plotted on the face to create 7 linear and 4 angular measurements which were measured directly (D) by a digital caliper and a protractor (www.examobile.com). Photos (2D) were taken with a Nikon DSLR camera and ring flash in NHP as well as a 3D-image with the 3dMD system (Atlanta, Georgia, USA). Both 2D photos and 3D images were analyzed by Tracker (www.opensourcephysics.org/Douglas Brown) and Vultus software for the same linear and angular parameters measured for each subject, respectively. 10% of the samples (5 cases) were randomly re-measured for intra-observer reproducibility. Collected data were analyzed by SAS using the paired t-test to compare the validity of direct (D), 2D and 3D measurements. Results: The results show no statistically significant difference between the direct measurement group (D) and 3D measurements. (p > 0.05) but a highly statistically significant difference is evident between the direct measurement group (D) and 2D measurements. (p < 0.01) The 2D and 3D measurement groups also showed a statistically significant difference.(p < 0.05) Conclusion: ➤ This study has validated the accuracy of 3D measurements versus direct measurement. ➤ 3D measurement techniques are more accurate, almost by 1mm in linear and up to 1 degree in angular measurements, than 2D techniques."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2019"]},{"key":"dc:title","label":"Title","values":["Validity and comparison between 2D (normal photo) and 3dMD (3D image) in orthodontic diagnosis"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Vint, Kevin (Preventive Dental Science)","Shah, Adnan (Dental Diagnostic and Surgical Sciences)"],"dc:contributor.supervisor":["Drummond, Robert (Preventive Dental Science) Wiltshire, William (Preventive Dental Science)"],"dc:creator":["Neishaboory, Amin"],"dc:date.accessioned":["2019-09-10T20:23:34Z"],"dc:date.available":["2019-09-10T20:23:34Z"],"dc:date.issued":["2018"],"dc:date.submitted":["2019-08-29T17:44:49Z"],"dc:description.abstract":["Objective: The aim was to evaluate the validity and comparison between direct anthropometry measurements as the “Gold Standard” with 2D-images (Normal Photo) and 3D-images (3dMD) as a new contemporary tool for orthodontic diagnosis. Methods & Materials: 51 subjects (22 Male and 29 Female) were randomly selected, without facial deformity, surgery or facial hair. Eight anatomical landmarks were selected and plotted on the face to create 7 linear and 4 angular measurements which were measured directly (D) by a digital caliper and a protractor (www.examobile.com). Photos (2D) were taken with a Nikon DSLR camera and ring flash in NHP as well as a 3D-image with the 3dMD system (Atlanta, Georgia, USA). Both 2D photos and 3D images were analyzed by Tracker (www.opensourcephysics.org/Douglas Brown) and Vultus software for the same linear and angular parameters measured for each subject, respectively. 10% of the samples (5 cases) were randomly re-measured for intra-observer reproducibility. Collected data were analyzed by SAS using the paired t-test to compare the validity of direct (D), 2D and 3D measurements. Results: The results show no statistically significant difference between the direct measurement group (D) and 3D measurements. (p > 0.05) but a highly statistically significant difference is evident between the direct measurement group (D) and 2D measurements. (p < 0.01) The 2D and 3D measurement groups also showed a statistically significant difference.(p < 0.05) Conclusion: ➤ This study has validated the accuracy of 3D measurements versus direct measurement. ➤ 3D measurement techniques are more accurate, almost by 1mm in linear and up to 1 degree in angular measurements, than 2D techniques."],"dc:description.note":["October 2019"],"dc:identifier.uri":["http://hdl.handle.net/1993/34197"],"dc:language.iso":["eng"],"dc:subject":["Facial diagnostic in orthodontics"],"dc:title":["Validity and comparison between 2D (normal photo) and 3dMD (3D image) in orthodontic diagnosis"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Preventive Dental Science"],"thesis:degree_level":["Master of Dentistry (M.Dent.)"]},"updated_at":"2026-11-19T09:03:34Z"}