{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/35012"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/35012","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Characterization of a Super-Kamiokande Photomultiplier tube using the TRIUMF PMT test facility","abstract":"This thesis describes the detailed response of a 20-in Super-Kamiokande Photomultiplier Tube (PMT). In particular the relative efficiency, transit time, transit time-spread, and single-photoelectron gain are mapped over the face of the PMT. These characteristics of the PMT are measured for different magnitudes of ambient magnetic field ranging from -100 mG to 100 mG. The measurements are done separately for the PMT in water and air. Detailed measurements of these PMT’s responses over their face have not been reported before, and will be useful inputs to studies of Super-Kamiokande detector systematic uncertainties. On average the variation in relative efficiency is 1% for PMT in water and 2% for the PMT in air. The RMS value of transit time and the transit time-spread of the PMT are found to change from 0.66 ns to 0.74 ns and 2.58 ns to 2.63 ns, respectively. Measurement shows the gain of the PMT varies from 362 to 400 in the ADC unit.","abstract_html":"This thesis describes the detailed response of a 20-in Super-Kamiokande Photomultiplier Tube (PMT). In particular the relative efficiency, transit time, transit time-spread, and single-photoelectron gain are mapped over the face of the PMT. These characteristics of the PMT are measured for different magnitudes of ambient magnetic field ranging from -100 mG to 100 mG. The measurements are done separately for the PMT in water and air. Detailed measurements of these PMT’s responses over their face have not been reported before, and will be useful inputs to studies of Super-Kamiokande detector systematic uncertainties. On average the variation in relative efficiency is 1% for PMT in water and 2% for the PMT in air. The RMS value of transit time and the transit time-spread of the PMT are found to change from 0.66 ns to 0.74 ns and 2.58 ns to 2.63 ns, respectively. Measurement shows the gain of the PMT varies from 362 to 400 in the ADC unit.","abstract_has_math":false,"creators":["Ahmadi, Shahin"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Jamieson, Blair (Physics and Astronomy)"],"committee_chairs":[],"committee_members":["Gwinner, Gerald (Physics and Astronomy)","Mammei, Juliette (Physics and Astronomy)"],"year":2020,"date_issued":"2020-08-24","date_published":"2020-08-24","updated_at":"2026-11-19T09:09:43Z","subjects":["Super-Kamiokande detector","20-in PMT","Characterization"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/35012","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/35012","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F35012","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F35012","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Gwinner, Gerald (Physics and Astronomy)","Mammei, Juliette (Physics and Astronomy)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Jamieson, Blair (Physics and Astronomy)"]},{"key":"dc:creator","label":"Author","values":["Ahmadi, Shahin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-09-09T12:58:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-09-09T12:58:33Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020-08-24"]},{"key":"dc:date.issued","label":"Date","values":["2020-08-24"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2020-08-24T17:20:20Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Super-Kamiokande detector","20-in PMT","Characterization"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/35012"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis describes the detailed response of a 20-in Super-Kamiokande Photomultiplier Tube (PMT). In particular the relative efficiency, transit time, transit time-spread, and single-photoelectron gain are mapped over the face of the PMT. These characteristics of the PMT are measured for different magnitudes of ambient magnetic field ranging from -100 mG to 100 mG. The measurements are done separately for the PMT in water and air. Detailed measurements of these PMT’s responses over their face have not been reported before, and will be useful inputs to studies of Super-Kamiokande detector systematic uncertainties. On average the variation in relative efficiency is 1% for PMT in water and 2% for the PMT in air. The RMS value of transit time and the transit time-spread of the PMT are found to change from 0.66 ns to 0.74 ns and 2.58 ns to 2.63 ns, respectively. Measurement shows the gain of the PMT varies from 362 to 400 in the ADC unit."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2020"]},{"key":"dc:title","label":"Title","values":["Characterization of a Super-Kamiokande Photomultiplier tube using the TRIUMF PMT test facility"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Gwinner, Gerald (Physics and Astronomy)","Mammei, Juliette (Physics and Astronomy)"],"dc:contributor.supervisor":["Jamieson, Blair (Physics and Astronomy)"],"dc:creator":["Ahmadi, Shahin"],"dc:date.accessioned":["2020-09-09T12:58:33Z"],"dc:date.available":["2020-09-09T12:58:33Z"],"dc:date.copyright":["2020-08-24"],"dc:date.issued":["2020-08-24"],"dc:date.submitted":["2020-08-24T17:20:20Z"],"dc:description.abstract":["This thesis describes the detailed response of a 20-in Super-Kamiokande Photomultiplier Tube (PMT). In particular the relative efficiency, transit time, transit time-spread, and single-photoelectron gain are mapped over the face of the PMT. These characteristics of the PMT are measured for different magnitudes of ambient magnetic field ranging from -100 mG to 100 mG. The measurements are done separately for the PMT in water and air. Detailed measurements of these PMT’s responses over their face have not been reported before, and will be useful inputs to studies of Super-Kamiokande detector systematic uncertainties. On average the variation in relative efficiency is 1% for PMT in water and 2% for the PMT in air. The RMS value of transit time and the transit time-spread of the PMT are found to change from 0.66 ns to 0.74 ns and 2.58 ns to 2.63 ns, respectively. Measurement shows the gain of the PMT varies from 362 to 400 in the ADC unit."],"dc:description.note":["October 2020"],"dc:identifier.uri":["http://hdl.handle.net/1993/35012"],"dc:language.iso":["eng"],"dc:subject":["Super-Kamiokande detector","20-in PMT","Characterization"],"dc:title":["Characterization of a Super-Kamiokande Photomultiplier tube using the TRIUMF PMT test facility"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:09:43Z"}