{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/36770"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/36770","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Development of a cost-effective detector for an MRI compatible brainPET","abstract":"Following the development of a Magnetic Resonance Imaging (MRI) compatible small animal Positron Emission Tomography (PET) insert, the University of Manitoba PET lab aims to develop an MRI compatible brainPET designed to retrofit into the Siemens Magnetom 7 T brain MRI. The purpose of this device is to perform simultaneous PET/MRI brain imaging for identification and diagnosis of brain and neck tumours, as well as neurodegenerative diseases. This thesis focuses on finding a suitable detector block through experimentation to be replicated 64 times to make up 4 rings of a 35 cm diameter brainPET insert. Experiments are conducted with a detector block and timing pick-off detector setup to capture 511 keV annihilation photon pairs emitted by a 22Na source, using the PETsys TOFPET2 ASIC for signal readout and digitization. The detector block is a Dual-Layer Offset (DLO) array of 2.4 mm pitch Lutetium-Yttrium Oxyorthosilicate (LYSO) scintillator crystals optically coupled to a sparse array of 3 mm Silicon Photomultiplier (SiPM) photosensors, with a 21 % fill factor. Motivating the low fill factor is the reduced cost of the detector, however it leads to scintillation light loss over the dead space on the photosensor board. To minimize light loss, reflective materials are placed on the board and tested, including Enhanced Specular Reflector (ESR), and white Polylactic Acid (PLA). The best result was with the PLA reflector, with a per-crystal average energy resolution of (18.5/19.0)% at 511 keV and Coincidence Timing Resolution (CTR) of (0.83/0.82)ns FWHM for the top/bottom layers of the scintillator. Lightguides promoting crystal-photosensor lightsharing were tested by calculating the resolvability of scintillator crystal positions measured by the detector. Of the lightguides tested, the 1.5 mm and 2.0 mm thicknesses produced the best crystal resolvability. Data processing techniques used for analysis are discussed, and parameters are tested by their effect on the results. Systematic timing offsets are discovered, and it is determined that there likely is not a DC offset in the TOFPET2 ASIC signal amplitude measurement.","abstract_html":"Following the development of a Magnetic Resonance Imaging (MRI) compatible small animal Positron Emission Tomography (PET) insert, the University of Manitoba PET lab aims to develop an MRI compatible brainPET designed to retrofit into the Siemens Magnetom 7 T brain MRI. The purpose of this device is to perform simultaneous PET/MRI brain imaging for identification and diagnosis of brain and neck tumours, as well as neurodegenerative diseases. This thesis focuses on finding a suitable detector block through experimentation to be replicated 64 times to make up 4 rings of a 35 cm diameter brainPET insert. Experiments are conducted with a detector block and timing pick-off detector setup to capture 511 keV annihilation photon pairs emitted by a 22Na source, using the PETsys TOFPET2 ASIC for signal readout and digitization. The detector block is a Dual-Layer Offset (DLO) array of 2.4 mm pitch Lutetium-Yttrium Oxyorthosilicate (LYSO) scintillator crystals optically coupled to a sparse array of 3 mm Silicon Photomultiplier (SiPM) photosensors, with a 21 % fill factor. Motivating the low fill factor is the reduced cost of the detector, however it leads to scintillation light loss over the dead space on the photosensor board. To minimize light loss, reflective materials are placed on the board and tested, including Enhanced Specular Reflector (ESR), and white Polylactic Acid (PLA). The best result was with the PLA reflector, with a per-crystal average energy resolution of (18.5/19.0)% at 511 keV and Coincidence Timing Resolution (CTR) of (0.83/0.82)ns FWHM for the top/bottom layers of the scintillator. Lightguides promoting crystal-photosensor lightsharing were tested by calculating the resolvability of scintillator crystal positions measured by the detector. Of the lightguides tested, the 1.5 mm and 2.0 mm thicknesses produced the best crystal resolvability. Data processing techniques used for analysis are discussed, and parameters are tested by their effect on the results. Systematic timing offsets are discovered, and it is determined that there likely is not a DC offset in the TOFPET2 ASIC signal amplitude measurement.","abstract_has_math":false,"creators":["Russell, Cameron J."],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Goertzen, Andrew"],"committee_chairs":[],"committee_members":["Longo, Savino (Physics and Astronomy)","Ingleby, Harry (Radiology, CancerCare Manitoba)","Goertzen, Andrew (Physics and Astronomy, Radiology)"],"year":2022,"date_issued":"2022-08-25","date_published":"2022-08-25","updated_at":"2026-11-19T09:08:17Z","subjects":["Scintillation detector","Positron emission tomography","Sparse Photosensor Array","Dual-layer offset","Lutetium-Yttrium Oxyorthosilicate","BrainPET","Lightguide"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/36770","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/36770","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F36770","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F36770","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Longo, Savino (Physics and Astronomy)","Ingleby, Harry (Radiology, CancerCare Manitoba)","Goertzen, Andrew (Physics and Astronomy, Radiology)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Goertzen, Andrew"]},{"key":"dc:creator","label":"Author","values":["Russell, Cameron J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-08-25T19:11:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-08-25T19:11:37Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2022-08-25"]},{"key":"dc:date.issued","label":"Date","values":["2022-08-25"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2022-08-25T18:43:29Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Scintillation detector","Positron emission tomography","Sparse Photosensor Array","Dual-layer offset","Lutetium-Yttrium Oxyorthosilicate","BrainPET","Lightguide"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/36770"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"crisitem:project.funder","label":"Crisitem Project Funder","values":["Natural Sciences and Engineering Research Council of Canada"]},{"key":"dc:description.abstract","label":"Abstract","values":["Following the development of a Magnetic Resonance Imaging (MRI) compatible small animal Positron Emission Tomography (PET) insert, the University of Manitoba PET lab aims to develop an MRI compatible brainPET designed to retrofit into the Siemens Magnetom 7 T brain MRI. The purpose of this device is to perform simultaneous PET/MRI brain imaging for identification and diagnosis of brain and neck tumours, as well as neurodegenerative diseases. This thesis focuses on finding a suitable detector block through experimentation to be replicated 64 times to make up 4 rings of a 35 cm diameter brainPET insert. Experiments are conducted with a detector block and timing pick-off detector setup to capture 511 keV annihilation photon pairs emitted by a 22Na source, using the PETsys TOFPET2 ASIC for signal readout and digitization. The detector block is a Dual-Layer Offset (DLO) array of 2.4 mm pitch Lutetium-Yttrium Oxyorthosilicate (LYSO) scintillator crystals optically coupled to a sparse array of 3 mm Silicon Photomultiplier (SiPM) photosensors, with a 21 % fill factor. Motivating the low fill factor is the reduced cost of the detector, however it leads to scintillation light loss over the dead space on the photosensor board. To minimize light loss, reflective materials are placed on the board and tested, including Enhanced Specular Reflector (ESR), and white Polylactic Acid (PLA). The best result was with the PLA reflector, with a per-crystal average energy resolution of (18.5/19.0)% at 511 keV and Coincidence Timing Resolution (CTR) of (0.83/0.82)ns FWHM for the top/bottom layers of the scintillator. Lightguides promoting crystal-photosensor lightsharing were tested by calculating the resolvability of scintillator crystal positions measured by the detector. Of the lightguides tested, the 1.5 mm and 2.0 mm thicknesses produced the best crystal resolvability. Data processing techniques used for analysis are discussed, and parameters are tested by their effect on the results. Systematic timing offsets are discovered, and it is determined that there likely is not a DC offset in the TOFPET2 ASIC signal amplitude measurement."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2022"]},{"key":"dc:title","label":"Title","values":["Development of a cost-effective detector for an MRI compatible brainPET"]},{"key":"local:admin","label":"Local Admin","values":["no"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"crisitem:project.funder":["Natural Sciences and Engineering Research Council of Canada"],"dc:contributor.committeemember":["Longo, Savino (Physics and Astronomy)","Ingleby, Harry (Radiology, CancerCare Manitoba)","Goertzen, Andrew (Physics and Astronomy, Radiology)"],"dc:contributor.supervisor":["Goertzen, Andrew"],"dc:creator":["Russell, Cameron J."],"dc:date.accessioned":["2022-08-25T19:11:37Z"],"dc:date.available":["2022-08-25T19:11:37Z"],"dc:date.copyright":["2022-08-25"],"dc:date.issued":["2022-08-25"],"dc:date.submitted":["2022-08-25T18:43:29Z"],"dc:description.abstract":["Following the development of a Magnetic Resonance Imaging (MRI) compatible small animal Positron Emission Tomography (PET) insert, the University of Manitoba PET lab aims to develop an MRI compatible brainPET designed to retrofit into the Siemens Magnetom 7 T brain MRI. The purpose of this device is to perform simultaneous PET/MRI brain imaging for identification and diagnosis of brain and neck tumours, as well as neurodegenerative diseases. This thesis focuses on finding a suitable detector block through experimentation to be replicated 64 times to make up 4 rings of a 35 cm diameter brainPET insert. Experiments are conducted with a detector block and timing pick-off detector setup to capture 511 keV annihilation photon pairs emitted by a 22Na source, using the PETsys TOFPET2 ASIC for signal readout and digitization. The detector block is a Dual-Layer Offset (DLO) array of 2.4 mm pitch Lutetium-Yttrium Oxyorthosilicate (LYSO) scintillator crystals optically coupled to a sparse array of 3 mm Silicon Photomultiplier (SiPM) photosensors, with a 21 % fill factor. Motivating the low fill factor is the reduced cost of the detector, however it leads to scintillation light loss over the dead space on the photosensor board. To minimize light loss, reflective materials are placed on the board and tested, including Enhanced Specular Reflector (ESR), and white Polylactic Acid (PLA). The best result was with the PLA reflector, with a per-crystal average energy resolution of (18.5/19.0)% at 511 keV and Coincidence Timing Resolution (CTR) of (0.83/0.82)ns FWHM for the top/bottom layers of the scintillator. Lightguides promoting crystal-photosensor lightsharing were tested by calculating the resolvability of scintillator crystal positions measured by the detector. Of the lightguides tested, the 1.5 mm and 2.0 mm thicknesses produced the best crystal resolvability. Data processing techniques used for analysis are discussed, and parameters are tested by their effect on the results. Systematic timing offsets are discovered, and it is determined that there likely is not a DC offset in the TOFPET2 ASIC signal amplitude measurement."],"dc:description.note":["October 2022"],"dc:identifier.uri":["http://hdl.handle.net/1993/36770"],"dc:language.iso":["eng"],"dc:subject":["Scintillation detector","Positron emission tomography","Sparse Photosensor Array","Dual-layer offset","Lutetium-Yttrium Oxyorthosilicate","BrainPET","Lightguide"],"dc:title":["Development of a cost-effective detector for an MRI compatible brainPET"],"dc:type":["master thesis"],"local:admin":["no"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:08:17Z"}