{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/39201"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/39201","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Comparative analysis of polymerization efficiency of Icon resin infiltrant and Embrace Wetbond sealant under varying curing conditions","abstract":"Purpose: This study evaluates the degree of conversion (DC) of Icon resin infiltrant and Wetbond sealant under varying clinical conditions, including differences in substrate type, curing angle, and distance. Methods: Tabletop samples of Icon resin infiltrant and Wetbond sealant were prepared and cured at two distances: 0 cm and 1 cm from the curing light unit. Fourier Transform Infrared Spectroscopy (FTIR) was used to determine the degree of conversion of these samples. To simulate clinical conditions, extracted teeth were mounted in wax to replicate the positioning and angles of curing in the oral cavity. Icon resin infiltrant and Wetbond sealant were applied interproximally and cured at distances of 0 cm and 1 cm. FTIR analysis was performed to measure the degree of conversion, and statistical comparisons were conducted using ANOVA and Tukey's post-hoc test. Conclusions: Results indicate that Icon resin infiltrant consistently achieves a significantly higher degree of conversion than Wetbond sealant across all tested conditions. The degree of conversion was influenced by substrate type and decreased with more distal curing angles, highlighting challenges in achieving optimal polymerization in less accessible areas of the oral cavity. These findings suggest that Icon may be a more reliable material than Wetbond sealant in terms of degree of conversion. However, further research is required to evaluate other properties and the clinical performance of these materials.","abstract_html":"Purpose: This study evaluates the degree of conversion (DC) of Icon resin infiltrant and Wetbond sealant under varying clinical conditions, including differences in substrate type, curing angle, and distance. Methods: Tabletop samples of Icon resin infiltrant and Wetbond sealant were prepared and cured at two distances: 0 cm and 1 cm from the curing light unit. Fourier Transform Infrared Spectroscopy (FTIR) was used to determine the degree of conversion of these samples. To simulate clinical conditions, extracted teeth were mounted in wax to replicate the positioning and angles of curing in the oral cavity. Icon resin infiltrant and Wetbond sealant were applied interproximally and cured at distances of 0 cm and 1 cm. FTIR analysis was performed to measure the degree of conversion, and statistical comparisons were conducted using ANOVA and Tukey&#x27;s post-hoc test. Conclusions: Results indicate that Icon resin infiltrant consistently achieves a significantly higher degree of conversion than Wetbond sealant across all tested conditions. The degree of conversion was influenced by substrate type and decreased with more distal curing angles, highlighting challenges in achieving optimal polymerization in less accessible areas of the oral cavity. These findings suggest that Icon may be a more reliable material than Wetbond sealant in terms of degree of conversion. However, further research is required to evaluate other properties and the clinical performance of these materials.","abstract_has_math":false,"creators":["Abu Sharkh, Farah"],"institution":null,"degree_name":null,"degree_level":"Master of Dentistry (M.Dent.)","degree_discipline":"Preventive Dental Science (Pediatric Dentistry)","degree_department":null,"school":null,"contributors":[],"advisors":["França, Rodrigo"],"committee_chairs":[],"committee_members":["Haimeur, Asmaa (Restorative Dentistry)","Amelgharib, Shima (Children's Dental World)"],"year":2025,"date_issued":"2025-06-19","date_published":"2025-06-19","updated_at":"2026-11-19T09:10:03Z","subjects":["Icon resin infiltrant","Embrace Wetbond pit and fissure sealant","Degree of conversion","Polymerization","FTIR spectroscopy","Dental materials"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/39201","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/39201","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F39201","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F39201","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Haimeur, Asmaa (Restorative Dentistry)","Amelgharib, Shima (Children's Dental World)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["França, Rodrigo"]},{"key":"dc:creator","label":"Author","values":["Abu Sharkh, Farah"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-08-06T14:29:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-08-06T14:29:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-06-19"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025-06-20T20:20:02Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Preventive Dental Science (Pediatric Dentistry)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Dentistry (M.Dent.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Icon resin infiltrant","Embrace Wetbond pit and fissure sealant","Degree of conversion","Polymerization","FTIR spectroscopy","Dental materials"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/39201"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"crisitem:project.funder","label":"Crisitem Project Funder","values":["University of Manitoba"]},{"key":"crisitem:project.title","label":"Crisitem Project Title","values":["Endowment Fund"]},{"key":"dc:description.abstract","label":"Abstract","values":["Purpose: This study evaluates the degree of conversion (DC) of Icon resin infiltrant and Wetbond sealant under varying clinical conditions, including differences in substrate type, curing angle, and distance. Methods: Tabletop samples of Icon resin infiltrant and Wetbond sealant were prepared and cured at two distances: 0 cm and 1 cm from the curing light unit. Fourier Transform Infrared Spectroscopy (FTIR) was used to determine the degree of conversion of these samples. To simulate clinical conditions, extracted teeth were mounted in wax to replicate the positioning and angles of curing in the oral cavity. Icon resin infiltrant and Wetbond sealant were applied interproximally and cured at distances of 0 cm and 1 cm. FTIR analysis was performed to measure the degree of conversion, and statistical comparisons were conducted using ANOVA and Tukey's post-hoc test. Conclusions: Results indicate that Icon resin infiltrant consistently achieves a significantly higher degree of conversion than Wetbond sealant across all tested conditions. The degree of conversion was influenced by substrate type and decreased with more distal curing angles, highlighting challenges in achieving optimal polymerization in less accessible areas of the oral cavity. These findings suggest that Icon may be a more reliable material than Wetbond sealant in terms of degree of conversion. However, further research is required to evaluate other properties and the clinical performance of these materials."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2025"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Charles Lekic Graduate Pediatric Dentistry Award"]},{"key":"dc:title","label":"Title","values":["Comparative analysis of polymerization efficiency of Icon resin infiltrant and Embrace Wetbond sealant under varying curing conditions"]},{"key":"local:admin","label":"Local Admin","values":["no"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"crisitem:project.funder":["University of Manitoba"],"crisitem:project.title":["Endowment Fund"],"dc:contributor.committeemember":["Haimeur, Asmaa (Restorative Dentistry)","Amelgharib, Shima (Children's Dental World)"],"dc:contributor.supervisor":["França, Rodrigo"],"dc:creator":["Abu Sharkh, Farah"],"dc:date.accessioned":["2025-08-06T14:29:18Z"],"dc:date.available":["2025-08-06T14:29:18Z"],"dc:date.issued":["2025-06-19"],"dc:date.submitted":["2025-06-20T20:20:02Z"],"dc:description.abstract":["Purpose: This study evaluates the degree of conversion (DC) of Icon resin infiltrant and Wetbond sealant under varying clinical conditions, including differences in substrate type, curing angle, and distance. Methods: Tabletop samples of Icon resin infiltrant and Wetbond sealant were prepared and cured at two distances: 0 cm and 1 cm from the curing light unit. Fourier Transform Infrared Spectroscopy (FTIR) was used to determine the degree of conversion of these samples. To simulate clinical conditions, extracted teeth were mounted in wax to replicate the positioning and angles of curing in the oral cavity. Icon resin infiltrant and Wetbond sealant were applied interproximally and cured at distances of 0 cm and 1 cm. FTIR analysis was performed to measure the degree of conversion, and statistical comparisons were conducted using ANOVA and Tukey's post-hoc test. Conclusions: Results indicate that Icon resin infiltrant consistently achieves a significantly higher degree of conversion than Wetbond sealant across all tested conditions. The degree of conversion was influenced by substrate type and decreased with more distal curing angles, highlighting challenges in achieving optimal polymerization in less accessible areas of the oral cavity. These findings suggest that Icon may be a more reliable material than Wetbond sealant in terms of degree of conversion. However, further research is required to evaluate other properties and the clinical performance of these materials."],"dc:description.note":["October 2025"],"dc:description.sponsorship":["Charles Lekic Graduate Pediatric Dentistry Award"],"dc:identifier.uri":["http://hdl.handle.net/1993/39201"],"dc:language.iso":["eng"],"dc:subject":["Icon resin infiltrant","Embrace Wetbond pit and fissure sealant","Degree of conversion","Polymerization","FTIR spectroscopy","Dental materials"],"dc:title":["Comparative analysis of polymerization efficiency of Icon resin infiltrant and Embrace Wetbond sealant under varying curing conditions"],"local:admin":["no"],"others:access_status":["embargo"],"thesis:degree_discipline":["Preventive Dental Science (Pediatric Dentistry)"],"thesis:degree_level":["Master of Dentistry (M.Dent.)"]},"updated_at":"2026-11-19T09:10:03Z"}