{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/39291"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/39291","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"A study of extrusion printed millimetre-scale MEMS transducers","abstract":"This thesis presents a comparison in performance of various microelectromechanical devices fabricated by both lithographic methods in a clean room facility and by means of extrusion printing of conductive ink. Traditional microelectromechanical systems (MEMS) fabrication practices involve costly, time-consuming and complex multi-step processes utilising high-end, high-maintenance cleanroom facilities. On the other hand, printed electronics (PE) offers quick turn-around time, low-cost, and simplicity. The work completed in this thesis involves taking candidate MEMS transducer designs intended for clean room fabrication and scaling them up to the resolution of a direct-ink write extrusion printer. Firstly, unknown ink parameters are determined through experimentation and simulation. Then, past MEMS designs for a Lorentz actuator and DC electric field sensor are scaled up and in some cases changed slightly to accommodate PE. A Lorentz actuator-based electromagnetic relay is designed as well. The devices are then fabricated using a direct ink writing (DIW) printer in conjunction with a laser micro-machining tool, and are tested to both verify the simulations and offer comparison to their respective MEMS counterparts and/or other similar devices from the literature. A key finding was comparable performance metrics between the PE devices fabricated in this thesis, and their respective lithographic or commercially available counterparts. This signifies that PE is a viable alternative to lithography for manufacturing some MEMS devices, or at least offers itself as a means of rapid prototyping. In addition, the ink used in this thesis was characterized for use in simulation models.","abstract_html":"This thesis presents a comparison in performance of various microelectromechanical devices fabricated by both lithographic methods in a clean room facility and by means of extrusion printing of conductive ink. Traditional microelectromechanical systems (MEMS) fabrication practices involve costly, time-consuming and complex multi-step processes utilising high-end, high-maintenance cleanroom facilities. On the other hand, printed electronics (PE) offers quick turn-around time, low-cost, and simplicity. The work completed in this thesis involves taking candidate MEMS transducer designs intended for clean room fabrication and scaling them up to the resolution of a direct-ink write extrusion printer. Firstly, unknown ink parameters are determined through experimentation and simulation. Then, past MEMS designs for a Lorentz actuator and DC electric field sensor are scaled up and in some cases changed slightly to accommodate PE. A Lorentz actuator-based electromagnetic relay is designed as well. The devices are then fabricated using a direct ink writing (DIW) printer in conjunction with a laser micro-machining tool, and are tested to both verify the simulations and offer comparison to their respective MEMS counterparts and/or other similar devices from the literature. A key finding was comparable performance metrics between the PE devices fabricated in this thesis, and their respective lithographic or commercially available counterparts. This signifies that PE is a viable alternative to lithography for manufacturing some MEMS devices, or at least offers itself as a means of rapid prototyping. In addition, the ink used in this thesis was characterized for use in simulation models.","abstract_has_math":false,"creators":["Lagace, Desmond"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Shafai, Cyrus"],"committee_chairs":[],"committee_members":["Bridges, Greg (Electrical and Computer Engineering)","Thomson, Douglas (Electrical and Computer Engineering)"],"year":2025,"date_issued":"2025-08-22","date_published":"2025-08-22","updated_at":"2026-11-19T09:02:55Z","subjects":["Printed electronics","MEMS","Additive manufacturing"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/39291","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/39291","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F39291","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F39291","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bridges, Greg (Electrical and Computer Engineering)","Thomson, Douglas (Electrical and Computer Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Shafai, Cyrus"]},{"key":"dc:creator","label":"Author","values":["Lagace, Desmond"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-09-04T14:18:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-09-04T14:18:16Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-08-22"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025-08-22T17:46:42Z","2025-09-04T02:31:58Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Printed electronics","MEMS","Additive manufacturing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/39291"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents a comparison in performance of various microelectromechanical devices fabricated by both lithographic methods in a clean room facility and by means of extrusion printing of conductive ink. Traditional microelectromechanical systems (MEMS) fabrication practices involve costly, time-consuming and complex multi-step processes utilising high-end, high-maintenance cleanroom facilities. On the other hand, printed electronics (PE) offers quick turn-around time, low-cost, and simplicity. The work completed in this thesis involves taking candidate MEMS transducer designs intended for clean room fabrication and scaling them up to the resolution of a direct-ink write extrusion printer. Firstly, unknown ink parameters are determined through experimentation and simulation. Then, past MEMS designs for a Lorentz actuator and DC electric field sensor are scaled up and in some cases changed slightly to accommodate PE. A Lorentz actuator-based electromagnetic relay is designed as well. The devices are then fabricated using a direct ink writing (DIW) printer in conjunction with a laser micro-machining tool, and are tested to both verify the simulations and offer comparison to their respective MEMS counterparts and/or other similar devices from the literature. A key finding was comparable performance metrics between the PE devices fabricated in this thesis, and their respective lithographic or commercially available counterparts. This signifies that PE is a viable alternative to lithography for manufacturing some MEMS devices, or at least offers itself as a means of rapid prototyping. In addition, the ink used in this thesis was characterized for use in simulation models."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2025"]},{"key":"dc:title","label":"Title","values":["A study of extrusion printed millimetre-scale MEMS transducers"]},{"key":"local:admin","label":"Local Admin","values":["no"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Bridges, Greg (Electrical and Computer Engineering)","Thomson, Douglas (Electrical and Computer Engineering)"],"dc:contributor.supervisor":["Shafai, Cyrus"],"dc:creator":["Lagace, Desmond"],"dc:date.accessioned":["2025-09-04T14:18:16Z"],"dc:date.available":["2025-09-04T14:18:16Z"],"dc:date.issued":["2025-08-22"],"dc:date.submitted":["2025-08-22T17:46:42Z","2025-09-04T02:31:58Z"],"dc:description.abstract":["This thesis presents a comparison in performance of various microelectromechanical devices fabricated by both lithographic methods in a clean room facility and by means of extrusion printing of conductive ink. Traditional microelectromechanical systems (MEMS) fabrication practices involve costly, time-consuming and complex multi-step processes utilising high-end, high-maintenance cleanroom facilities. On the other hand, printed electronics (PE) offers quick turn-around time, low-cost, and simplicity. The work completed in this thesis involves taking candidate MEMS transducer designs intended for clean room fabrication and scaling them up to the resolution of a direct-ink write extrusion printer. Firstly, unknown ink parameters are determined through experimentation and simulation. Then, past MEMS designs for a Lorentz actuator and DC electric field sensor are scaled up and in some cases changed slightly to accommodate PE. A Lorentz actuator-based electromagnetic relay is designed as well. The devices are then fabricated using a direct ink writing (DIW) printer in conjunction with a laser micro-machining tool, and are tested to both verify the simulations and offer comparison to their respective MEMS counterparts and/or other similar devices from the literature. A key finding was comparable performance metrics between the PE devices fabricated in this thesis, and their respective lithographic or commercially available counterparts. This signifies that PE is a viable alternative to lithography for manufacturing some MEMS devices, or at least offers itself as a means of rapid prototyping. In addition, the ink used in this thesis was characterized for use in simulation models."],"dc:description.note":["October 2025"],"dc:identifier.uri":["http://hdl.handle.net/1993/39291"],"dc:language.iso":["eng"],"dc:subject":["Printed electronics","MEMS","Additive manufacturing"],"dc:title":["A study of extrusion printed millimetre-scale MEMS transducers"],"local:admin":["no"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:02:55Z"}