{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/39339"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/39339","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Evaluating the efficiency of the different resilient overdenture attachments in implant-assisted cast partial dentures","abstract":"This study aims to assess the wear resistance of various robust attachments in implant-assisted removable partial overdentures over abutments such as Ball Cap, LOCATOR, and Novaloc. Each of the three attachment groups—Ball Cap (Rhein83), LOCATOR (Preat), and Novaloc (Straumann)—has a sample size of 10 each. The angle at which the attachment would be loaded would be between 0 and 10 degrees. Newton-centimeters (N-cm) of retention would be assessed both before and after 5000 cycles of load application and removal. The subsequent attachment wear will be examined under scanning electron microscope. A patient’s model with missing mandibular posterior teeth were used to design Kennedy class I implant-assisted removable partial denture (IARPD). The implant replica were placed bilaterally in the 1st molar region using manufactures recommendation. The scan bodies were digitally scanned using Prime Scan (Dentsply Sirona) intraoral scanner after hand tightened. Three models were printed, one for each attachment type, and the cast IARPDs were designed on the models. The IARPDs were constructed in the laboratory. The attachments were placed in the IARPDs. The custom-made replica of the testing device was designed using Exocad software. The attachment specimen was observed under scanning electron microscope. The degree of attachment wear was recorded and compared within the group and against the controls for evaluation. There are statistically significant differences in the diameter of the ball cap, Locator and Novaloc attachments. The nylon Ball cap attachment shows significantly more wear after 5000 cycles compared to the nylon Locator and polyetheretherketone (PEEK) Novaloc attachment. Resilient attachments wear differently depending on the type and material after cyclic load is applied on an IARPD.","abstract_html":"This study aims to assess the wear resistance of various robust attachments in implant-assisted removable partial overdentures over abutments such as Ball Cap, LOCATOR, and Novaloc. Each of the three attachment groups—Ball Cap (Rhein83), LOCATOR (Preat), and Novaloc (Straumann)—has a sample size of 10 each. The angle at which the attachment would be loaded would be between 0 and 10 degrees. Newton-centimeters (N-cm) of retention would be assessed both before and after 5000 cycles of load application and removal. The subsequent attachment wear will be examined under scanning electron microscope. A patient’s model with missing mandibular posterior teeth were used to design Kennedy class I implant-assisted removable partial denture (IARPD). The implant replica were placed bilaterally in the 1st molar region using manufactures recommendation. The scan bodies were digitally scanned using Prime Scan (Dentsply Sirona) intraoral scanner after hand tightened. Three models were printed, one for each attachment type, and the cast IARPDs were designed on the models. The IARPDs were constructed in the laboratory. The attachments were placed in the IARPDs. The custom-made replica of the testing device was designed using Exocad software. The attachment specimen was observed under scanning electron microscope. The degree of attachment wear was recorded and compared within the group and against the controls for evaluation. There are statistically significant differences in the diameter of the ball cap, Locator and Novaloc attachments. The nylon Ball cap attachment shows significantly more wear after 5000 cycles compared to the nylon Locator and polyetheretherketone (PEEK) Novaloc attachment. Resilient attachments wear differently depending on the type and material after cyclic load is applied on an IARPD.","abstract_has_math":false,"creators":["Patel, Tarik"],"institution":null,"degree_name":null,"degree_level":"Master of Dentistry (M.Dent.)","degree_discipline":"Restorative Dentistry (Prosthodontics)","degree_department":null,"school":null,"contributors":[],"advisors":["Pesun , Igor"],"committee_chairs":[],"committee_members":["Nowakowski, Anthony (Restorative Dentistry)","Hunzinger, Vanessa (Restorative Dentistry)"],"year":2025,"date_issued":"2025-06-30","date_published":"2025-06-30","updated_at":"2026-11-19T09:05:20Z","subjects":["Ball & socket","Locator","Implant assisted removable partial overdenture","Removable prosthetics"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/39339","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/39339","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F39339","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F39339","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Nowakowski, Anthony (Restorative Dentistry)","Hunzinger, Vanessa (Restorative Dentistry)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Pesun , Igor"]},{"key":"dc:creator","label":"Author","values":["Patel, Tarik"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-09-11T17:59:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-09-11T17:59:59Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-06-30"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025-09-11T17:48:55Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Restorative Dentistry (Prosthodontics)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Dentistry (M.Dent.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ball & socket","Locator","Implant assisted removable partial overdenture","Removable prosthetics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/39339"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study aims to assess the wear resistance of various robust attachments in implant-assisted removable partial overdentures over abutments such as Ball Cap, LOCATOR, and Novaloc. Each of the three attachment groups—Ball Cap (Rhein83), LOCATOR (Preat), and Novaloc (Straumann)—has a sample size of 10 each. The angle at which the attachment would be loaded would be between 0 and 10 degrees. Newton-centimeters (N-cm) of retention would be assessed both before and after 5000 cycles of load application and removal. The subsequent attachment wear will be examined under scanning electron microscope. A patient’s model with missing mandibular posterior teeth were used to design Kennedy class I implant-assisted removable partial denture (IARPD). The implant replica were placed bilaterally in the 1st molar region using manufactures recommendation. The scan bodies were digitally scanned using Prime Scan (Dentsply Sirona) intraoral scanner after hand tightened. Three models were printed, one for each attachment type, and the cast IARPDs were designed on the models. The IARPDs were constructed in the laboratory. The attachments were placed in the IARPDs. The custom-made replica of the testing device was designed using Exocad software. The attachment specimen was observed under scanning electron microscope. The degree of attachment wear was recorded and compared within the group and against the controls for evaluation. There are statistically significant differences in the diameter of the ball cap, Locator and Novaloc attachments. The nylon Ball cap attachment shows significantly more wear after 5000 cycles compared to the nylon Locator and polyetheretherketone (PEEK) Novaloc attachment. Resilient attachments wear differently depending on the type and material after cyclic load is applied on an IARPD."]},{"key":"dc:description.note","label":"Dc Description Note","values":["May 2025"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["American Academy of Implant Dentistry"]},{"key":"dc:title","label":"Title","values":["Evaluating the efficiency of the different resilient overdenture attachments in implant-assisted cast partial dentures"]},{"key":"local:admin","label":"Local Admin","values":["no"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Nowakowski, Anthony (Restorative Dentistry)","Hunzinger, Vanessa (Restorative Dentistry)"],"dc:contributor.supervisor":["Pesun , Igor"],"dc:creator":["Patel, Tarik"],"dc:date.accessioned":["2025-09-11T17:59:59Z"],"dc:date.available":["2025-09-11T17:59:59Z"],"dc:date.issued":["2025-06-30"],"dc:date.submitted":["2025-09-11T17:48:55Z"],"dc:description.abstract":["This study aims to assess the wear resistance of various robust attachments in implant-assisted removable partial overdentures over abutments such as Ball Cap, LOCATOR, and Novaloc. Each of the three attachment groups—Ball Cap (Rhein83), LOCATOR (Preat), and Novaloc (Straumann)—has a sample size of 10 each. The angle at which the attachment would be loaded would be between 0 and 10 degrees. Newton-centimeters (N-cm) of retention would be assessed both before and after 5000 cycles of load application and removal. The subsequent attachment wear will be examined under scanning electron microscope. A patient’s model with missing mandibular posterior teeth were used to design Kennedy class I implant-assisted removable partial denture (IARPD). The implant replica were placed bilaterally in the 1st molar region using manufactures recommendation. The scan bodies were digitally scanned using Prime Scan (Dentsply Sirona) intraoral scanner after hand tightened. Three models were printed, one for each attachment type, and the cast IARPDs were designed on the models. The IARPDs were constructed in the laboratory. The attachments were placed in the IARPDs. The custom-made replica of the testing device was designed using Exocad software. The attachment specimen was observed under scanning electron microscope. The degree of attachment wear was recorded and compared within the group and against the controls for evaluation. There are statistically significant differences in the diameter of the ball cap, Locator and Novaloc attachments. The nylon Ball cap attachment shows significantly more wear after 5000 cycles compared to the nylon Locator and polyetheretherketone (PEEK) Novaloc attachment. Resilient attachments wear differently depending on the type and material after cyclic load is applied on an IARPD."],"dc:description.note":["May 2025"],"dc:description.sponsorship":["American Academy of Implant Dentistry"],"dc:identifier.uri":["http://hdl.handle.net/1993/39339"],"dc:language.iso":["eng"],"dc:subject":["Ball & socket","Locator","Implant assisted removable partial overdenture","Removable prosthetics"],"dc:title":["Evaluating the efficiency of the different resilient overdenture attachments in implant-assisted cast partial dentures"],"local:admin":["no"],"others:access_status":["open.access"],"thesis:degree_discipline":["Restorative Dentistry (Prosthodontics)"],"thesis:degree_level":["Master of Dentistry (M.Dent.)"]},"updated_at":"2026-11-19T09:05:20Z"}