{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/39508"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/39508","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Micro-bubbles enhance photon utilization efficiency in ultraviolet-based advanced oxidation processes","abstract":"Micropollutants are important issues in water treatment because some of them pose health risks to humans and the environment. Ultraviolet-based advanced oxidation processes (AOPs) have emerged to be effective in micropollutant control, which relies on UV photons to split oxidants into radical species that can destroy micropollutants. However, the photon utilization efficiency in most UV-based advanced oxidation processes (AOPs) is usually low, and the fundamental reason is that the UV photons travel too short a path length in the water before they hit and be absorbed by the reactor walls and other accessories (i.e., be wasted). To address this issue, this study integrated microbubbles into the system to “trap” photons in the water. The surfaces of numerous microbubbles scatter or reflect photons, changing the photons’ pathways from straight to torturous. This will keep the photons in the water long enough to interact with oxidants and less likely to reach the walls, resulting in performance enhancement. This study is designed to compare two widely used AOPs, UV/H₂O₂ and UV/chlorine, in micropollutant control at bench scale, with and without microbubbles. Nitrobenzene, benzoic acid, and caffeine are selected as representative micropollutants. The impact of microbubbles on AOP performance is evaluated under different conditions by monitoring the kinetics of oxidant (i.e., H₂O₂ or chlorine) and micropollutant decay and are quantified using the enhancement ratio kair/kno-air. The different test conditions are achieved by varying oxidant doses, reactor sizes (short vs long path lengths), water matrices (low transmittance vs high transmittance), and lamp types (low pressure and medium pressure). Microbubbles were generated using a CARMIN diffuser, producing stable bubbles predominantly in the 10–100 µm range. Results showed that aeration consistently enhanced oxidant decay and micropollutant removal, confirming that microbubbles improve photon availability by scattering and reflecting UV light within the reactor. The magnitude of enhancement depended on oxidant dose, bubble concentration, reactor geometry, and lamp type. Medium-pressure UV lamps exhibited the strongest response to aeration, given their broader emission spectrum and greater baseline photon losses. A distinct optimal bubble concentration was identified; too many bubbles reduced UV penetration, while too few provided minimal scattering benefit. Caffeine showed the highest enhancement among the micropollutants due to its faster radical-reaction kinetics, while nitrobenzene, the most resistant compound, exhibited modest but consistent improvement under aerated conditions. Overall, the findings demonstrate that microbubble-enhanced UV-AOPs offer a promising pathway to improve treatment performance, reduce photon losses, and optimize energy use in water treatment systems. The study provides experimental evidence and practical insights that can guide future reactor design, optimization of bubble parameters, and scale-up of aeration-assisted UV technologies.","abstract_html":"Micropollutants are important issues in water treatment because some of them pose health risks to humans and the environment. Ultraviolet-based advanced oxidation processes (AOPs) have emerged to be effective in micropollutant control, which relies on UV photons to split oxidants into radical species that can destroy micropollutants. However, the photon utilization efficiency in most UV-based advanced oxidation processes (AOPs) is usually low, and the fundamental reason is that the UV photons travel too short a path length in the water before they hit and be absorbed by the reactor walls and other accessories (i.e., be wasted). To address this issue, this study integrated microbubbles into the system to “trap” photons in the water. The surfaces of numerous microbubbles scatter or reflect photons, changing the photons’ pathways from straight to torturous. This will keep the photons in the water long enough to interact with oxidants and less likely to reach the walls, resulting in performance enhancement. This study is designed to compare two widely used AOPs, UV/H₂O₂ and UV/chlorine, in micropollutant control at bench scale, with and without microbubbles. Nitrobenzene, benzoic acid, and caffeine are selected as representative micropollutants. The impact of microbubbles on AOP performance is evaluated under different conditions by monitoring the kinetics of oxidant (i.e., H₂O₂ or chlorine) and micropollutant decay and are quantified using the enhancement ratio kair/kno-air. The different test conditions are achieved by varying oxidant doses, reactor sizes (short vs long path lengths), water matrices (low transmittance vs high transmittance), and lamp types (low pressure and medium pressure). Microbubbles were generated using a CARMIN diffuser, producing stable bubbles predominantly in the 10–100 µm range. Results showed that aeration consistently enhanced oxidant decay and micropollutant removal, confirming that microbubbles improve photon availability by scattering and reflecting UV light within the reactor. The magnitude of enhancement depended on oxidant dose, bubble concentration, reactor geometry, and lamp type. Medium-pressure UV lamps exhibited the strongest response to aeration, given their broader emission spectrum and greater baseline photon losses. A distinct optimal bubble concentration was identified; too many bubbles reduced UV penetration, while too few provided minimal scattering benefit. Caffeine showed the highest enhancement among the micropollutants due to its faster radical-reaction kinetics, while nitrobenzene, the most resistant compound, exhibited modest but consistent improvement under aerated conditions. Overall, the findings demonstrate that microbubble-enhanced UV-AOPs offer a promising pathway to improve treatment performance, reduce photon losses, and optimize energy use in water treatment systems. The study provides experimental evidence and practical insights that can guide future reactor design, optimization of bubble parameters, and scale-up of aeration-assisted UV technologies.","abstract_has_math":false,"creators":["Hamza, Hafiz"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Yuan, Qiuyan","Wang, Chengjin"],"committee_chairs":[],"committee_members":["Cicek, Nazim (Biosystems Engineering)","Gorczyca, Beata (Civil Engineering)"],"year":2025,"date_issued":"2025-12-19","date_published":"2025-12-19","updated_at":"2026-11-19T09:13:53Z","subjects":["Advanced Oxidation Process","Ultraviolet light source","Micropollutants","Oxidant Decay"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/39508","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/39508","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F39508","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F39508","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Cicek, Nazim (Biosystems Engineering)","Gorczyca, Beata (Civil Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Yuan, Qiuyan","Wang, Chengjin"]},{"key":"dc:creator","label":"Author","values":["Hamza, Hafiz"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-12-19T21:17:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-19T21:17:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-12-19"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025-12-19T20:27:36Z","2025-12-19T21:07:26Z","2025-12-19T21:13:41Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Advanced Oxidation Process","Ultraviolet light source","Micropollutants","Oxidant Decay"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/39508"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Micropollutants are important issues in water treatment because some of them pose health risks to humans and the environment. Ultraviolet-based advanced oxidation processes (AOPs) have emerged to be effective in micropollutant control, which relies on UV photons to split oxidants into radical species that can destroy micropollutants. However, the photon utilization efficiency in most UV-based advanced oxidation processes (AOPs) is usually low, and the fundamental reason is that the UV photons travel too short a path length in the water before they hit and be absorbed by the reactor walls and other accessories (i.e., be wasted). To address this issue, this study integrated microbubbles into the system to “trap” photons in the water. The surfaces of numerous microbubbles scatter or reflect photons, changing the photons’ pathways from straight to torturous. This will keep the photons in the water long enough to interact with oxidants and less likely to reach the walls, resulting in performance enhancement. This study is designed to compare two widely used AOPs, UV/H₂O₂ and UV/chlorine, in micropollutant control at bench scale, with and without microbubbles. Nitrobenzene, benzoic acid, and caffeine are selected as representative micropollutants. The impact of microbubbles on AOP performance is evaluated under different conditions by monitoring the kinetics of oxidant (i.e., H₂O₂ or chlorine) and micropollutant decay and are quantified using the enhancement ratio kair/kno-air. The different test conditions are achieved by varying oxidant doses, reactor sizes (short vs long path lengths), water matrices (low transmittance vs high transmittance), and lamp types (low pressure and medium pressure). Microbubbles were generated using a CARMIN diffuser, producing stable bubbles predominantly in the 10–100 µm range. Results showed that aeration consistently enhanced oxidant decay and micropollutant removal, confirming that microbubbles improve photon availability by scattering and reflecting UV light within the reactor. The magnitude of enhancement depended on oxidant dose, bubble concentration, reactor geometry, and lamp type. Medium-pressure UV lamps exhibited the strongest response to aeration, given their broader emission spectrum and greater baseline photon losses. A distinct optimal bubble concentration was identified; too many bubbles reduced UV penetration, while too few provided minimal scattering benefit. Caffeine showed the highest enhancement among the micropollutants due to its faster radical-reaction kinetics, while nitrobenzene, the most resistant compound, exhibited modest but consistent improvement under aerated conditions. Overall, the findings demonstrate that microbubble-enhanced UV-AOPs offer a promising pathway to improve treatment performance, reduce photon losses, and optimize energy use in water treatment systems. The study provides experimental evidence and practical insights that can guide future reactor design, optimization of bubble parameters, and scale-up of aeration-assisted UV technologies."]},{"key":"dc:description.note","label":"Dc Description Note","values":["February 2026"]},{"key":"dc:title","label":"Title","values":["Micro-bubbles enhance photon utilization efficiency in ultraviolet-based advanced oxidation processes"]},{"key":"local:admin","label":"Local Admin","values":["no"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Cicek, Nazim (Biosystems Engineering)","Gorczyca, Beata (Civil Engineering)"],"dc:contributor.supervisor":["Yuan, Qiuyan","Wang, Chengjin"],"dc:creator":["Hamza, Hafiz"],"dc:date.accessioned":["2025-12-19T21:17:48Z"],"dc:date.available":["2025-12-19T21:17:48Z"],"dc:date.issued":["2025-12-19"],"dc:date.submitted":["2025-12-19T20:27:36Z","2025-12-19T21:07:26Z","2025-12-19T21:13:41Z"],"dc:description.abstract":["Micropollutants are important issues in water treatment because some of them pose health risks to humans and the environment. Ultraviolet-based advanced oxidation processes (AOPs) have emerged to be effective in micropollutant control, which relies on UV photons to split oxidants into radical species that can destroy micropollutants. However, the photon utilization efficiency in most UV-based advanced oxidation processes (AOPs) is usually low, and the fundamental reason is that the UV photons travel too short a path length in the water before they hit and be absorbed by the reactor walls and other accessories (i.e., be wasted). To address this issue, this study integrated microbubbles into the system to “trap” photons in the water. The surfaces of numerous microbubbles scatter or reflect photons, changing the photons’ pathways from straight to torturous. This will keep the photons in the water long enough to interact with oxidants and less likely to reach the walls, resulting in performance enhancement. This study is designed to compare two widely used AOPs, UV/H₂O₂ and UV/chlorine, in micropollutant control at bench scale, with and without microbubbles. Nitrobenzene, benzoic acid, and caffeine are selected as representative micropollutants. The impact of microbubbles on AOP performance is evaluated under different conditions by monitoring the kinetics of oxidant (i.e., H₂O₂ or chlorine) and micropollutant decay and are quantified using the enhancement ratio kair/kno-air. The different test conditions are achieved by varying oxidant doses, reactor sizes (short vs long path lengths), water matrices (low transmittance vs high transmittance), and lamp types (low pressure and medium pressure). Microbubbles were generated using a CARMIN diffuser, producing stable bubbles predominantly in the 10–100 µm range. Results showed that aeration consistently enhanced oxidant decay and micropollutant removal, confirming that microbubbles improve photon availability by scattering and reflecting UV light within the reactor. The magnitude of enhancement depended on oxidant dose, bubble concentration, reactor geometry, and lamp type. Medium-pressure UV lamps exhibited the strongest response to aeration, given their broader emission spectrum and greater baseline photon losses. A distinct optimal bubble concentration was identified; too many bubbles reduced UV penetration, while too few provided minimal scattering benefit. Caffeine showed the highest enhancement among the micropollutants due to its faster radical-reaction kinetics, while nitrobenzene, the most resistant compound, exhibited modest but consistent improvement under aerated conditions. Overall, the findings demonstrate that microbubble-enhanced UV-AOPs offer a promising pathway to improve treatment performance, reduce photon losses, and optimize energy use in water treatment systems. The study provides experimental evidence and practical insights that can guide future reactor design, optimization of bubble parameters, and scale-up of aeration-assisted UV technologies."],"dc:description.note":["February 2026"],"dc:identifier.uri":["http://hdl.handle.net/1993/39508"],"dc:language.iso":["eng"],"dc:subject":["Advanced Oxidation Process","Ultraviolet light source","Micropollutants","Oxidant Decay"],"dc:title":["Micro-bubbles enhance photon utilization efficiency in ultraviolet-based advanced oxidation processes"],"local:admin":["no"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:13:53Z"}