{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/3951"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/3951","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Optimizing the management of hemodialysis catheter occlusion","abstract":"Hemodialysis catheter occlusion compromises hemodialysis adequacy and increases the cost of care. Repeated administration of alteplase in hemodialysis catheters typically produces only short-term benefits. The purpose of this study was to design, implement and evaluate the efficacy of a step-by-step algorithm to optimize the management of hemodialysis catheter occlusion. The study had a prospective quasi-experimental design in two parts. Baseline data on the use of alteplase and catheter exchange were collected during Part I; while, Part II consisted of algorithm implementation. Rates of alteplase use and catheter exchange per 1000 catheter days were main outcomes of the study. One-hundred and seventy-two catheters in 131 patients were followed up during the course of the study. The vast majority of the study population were on clopidogrel or aspirin (75%); whereas, approximately 11% were on warfarin. The adjusted rate of alteplase use was not significantly different after algorithm implementation (Part I vs. Part II relative risk: 1.10; 95% CI: 0.73 – 1.65, p > 0.05). Similarly, catheter exchange rates were not significantly different in both parts of the study (1.12 vs. 1.03 per 1000 catheter-days, p > 0.05). Regression analysis showed that the rate of alteplase use was inversely related to the catheter age (p < 0.05). In a secondary analysis on a subgroup of patients with occlusion-related catheter exchanges (n = 28), the number of alteplase administrations significantly increased with longer waiting time for catheter exchange (p < 0.05). In conclusion the hemodialysis catheter management algorithm was not effective in decreasing the rate of alteplase use.","abstract_html":"Hemodialysis catheter occlusion compromises hemodialysis adequacy and increases the cost of care. Repeated administration of alteplase in hemodialysis catheters typically produces only short-term benefits. The purpose of this study was to design, implement and evaluate the efficacy of a step-by-step algorithm to optimize the management of hemodialysis catheter occlusion. The study had a prospective quasi-experimental design in two parts. Baseline data on the use of alteplase and catheter exchange were collected during Part I; while, Part II consisted of algorithm implementation. Rates of alteplase use and catheter exchange per 1000 catheter days were main outcomes of the study. One-hundred and seventy-two catheters in 131 patients were followed up during the course of the study. The vast majority of the study population were on clopidogrel or aspirin (75%); whereas, approximately 11% were on warfarin. The adjusted rate of alteplase use was not significantly different after algorithm implementation (Part I vs. Part II relative risk: 1.10; 95% CI: 0.73 – 1.65, p &gt; 0.05). Similarly, catheter exchange rates were not significantly different in both parts of the study (1.12 vs. 1.03 per 1000 catheter-days, p &gt; 0.05). Regression analysis showed that the rate of alteplase use was inversely related to the catheter age (p &lt; 0.05). In a secondary analysis on a subgroup of patients with occlusion-related catheter exchanges (n = 28), the number of alteplase administrations significantly increased with longer waiting time for catheter exchange (p &lt; 0.05). In conclusion the hemodialysis catheter management algorithm was not effective in decreasing the rate of alteplase use.","abstract_has_math":false,"creators":["Abdelmoneim, Ahmed S."],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Pharmacy","degree_department":null,"school":null,"contributors":[],"advisors":["Vercaigne, Lavern (Pharmacy)"],"committee_chairs":[],"committee_members":["Collins, David (Pharmacy)","Miller, Lisa (Medicine)"],"year":2010,"date_issued":"2010-04-09T15:17:01Z","date_published":"2010-04-09T15:17:01Z","updated_at":"2026-11-19T09:10:37Z","subjects":["Hemodialysis","Catheter","Alteplase","Algorithm"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/3951","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/3951","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F3951","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F3951","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Collins, David (Pharmacy)","Miller, Lisa (Medicine)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Vercaigne, Lavern (Pharmacy)"]},{"key":"dc:creator","label":"Author","values":["Abdelmoneim, Ahmed S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-04-09T15:17:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-04-09T15:17:01Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-04-09T15:17:01Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Pharmacy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hemodialysis","Catheter","Alteplase","Algorithm"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/3951"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hemodialysis catheter occlusion compromises hemodialysis adequacy and increases the cost of care. Repeated administration of alteplase in hemodialysis catheters typically produces only short-term benefits. The purpose of this study was to design, implement and evaluate the efficacy of a step-by-step algorithm to optimize the management of hemodialysis catheter occlusion. The study had a prospective quasi-experimental design in two parts. Baseline data on the use of alteplase and catheter exchange were collected during Part I; while, Part II consisted of algorithm implementation. Rates of alteplase use and catheter exchange per 1000 catheter days were main outcomes of the study. One-hundred and seventy-two catheters in 131 patients were followed up during the course of the study. The vast majority of the study population were on clopidogrel or aspirin (75%); whereas, approximately 11% were on warfarin. The adjusted rate of alteplase use was not significantly different after algorithm implementation (Part I vs. Part II relative risk: 1.10; 95% CI: 0.73 – 1.65, p > 0.05). Similarly, catheter exchange rates were not significantly different in both parts of the study (1.12 vs. 1.03 per 1000 catheter-days, p > 0.05). Regression analysis showed that the rate of alteplase use was inversely related to the catheter age (p < 0.05). In a secondary analysis on a subgroup of patients with occlusion-related catheter exchanges (n = 28), the number of alteplase administrations significantly increased with longer waiting time for catheter exchange (p < 0.05). In conclusion the hemodialysis catheter management algorithm was not effective in decreasing the rate of alteplase use."]},{"key":"dc:description.note","label":"Dc Description Note","values":["May 2010"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1231163 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Optimizing the management of hemodialysis catheter occlusion"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Collins, David (Pharmacy)","Miller, Lisa (Medicine)"],"dc:contributor.supervisor":["Vercaigne, Lavern (Pharmacy)"],"dc:creator":["Abdelmoneim, Ahmed S."],"dc:date.accessioned":["2010-04-09T15:17:01Z"],"dc:date.available":["2010-04-09T15:17:01Z"],"dc:date.issued":["2010-04-09T15:17:01Z"],"dc:description.abstract":["Hemodialysis catheter occlusion compromises hemodialysis adequacy and increases the cost of care. Repeated administration of alteplase in hemodialysis catheters typically produces only short-term benefits. The purpose of this study was to design, implement and evaluate the efficacy of a step-by-step algorithm to optimize the management of hemodialysis catheter occlusion. The study had a prospective quasi-experimental design in two parts. Baseline data on the use of alteplase and catheter exchange were collected during Part I; while, Part II consisted of algorithm implementation. Rates of alteplase use and catheter exchange per 1000 catheter days were main outcomes of the study. One-hundred and seventy-two catheters in 131 patients were followed up during the course of the study. The vast majority of the study population were on clopidogrel or aspirin (75%); whereas, approximately 11% were on warfarin. The adjusted rate of alteplase use was not significantly different after algorithm implementation (Part I vs. Part II relative risk: 1.10; 95% CI: 0.73 – 1.65, p > 0.05). Similarly, catheter exchange rates were not significantly different in both parts of the study (1.12 vs. 1.03 per 1000 catheter-days, p > 0.05). Regression analysis showed that the rate of alteplase use was inversely related to the catheter age (p < 0.05). In a secondary analysis on a subgroup of patients with occlusion-related catheter exchanges (n = 28), the number of alteplase administrations significantly increased with longer waiting time for catheter exchange (p < 0.05). In conclusion the hemodialysis catheter management algorithm was not effective in decreasing the rate of alteplase use."],"dc:description.note":["May 2010"],"dc:format.extent":["1231163 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1993/3951"],"dc:language.iso":["eng"],"dc:subject":["Hemodialysis","Catheter","Alteplase","Algorithm"],"dc:title":["Optimizing the management of hemodialysis catheter occlusion"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Pharmacy"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:10:37Z"}