{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/39615"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/39615","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Investigation of loss of synchronism phenomenon in synchronous machines and protection using trajectory of relative speed","abstract":"The \"loss of synchronism\" condition in a synchronous machine is a critical state where the rotor fails to stay synchronized with the stator magnetic field. This can be caused by various factors, including system disturbances and power system instabilities. A machine undergoing a loss of synchronism may experiences torsional stresses, increased rotor iron currents and winding stresses in their mechanical systems. Synchronous machine loss of synchronism protection is employed to promptly disconnect a machine operating asynchronously to avoid damage or degradation. This thesis explores the loss of synchronism phenomenon in synchronous generators and introduces a novel loss of synchronism detection method based on the estimated relative speed of the rotor. The proposed algorithm utilizes readily available terminal voltage, current and machine parameters to estimate the rotor speed following a disturbance. It identifies loss of synchronism condition if the estimated relative speed tends to increase during a swing cycle. This method is computationally simple, easy to implement, and faster than impedance-based techniques under certain conditions. The sensitivity and security of this method is evaluated through time-domain simulations under various power system conditions. The performance of the proposed method is also compared against well established loss of synchronism protection schemes. The occurrence of loss of synchronism in synchronous condensers has not been extensively studied, primarily due to its rarity in traditional power systems. However, with the increasing integration of inverter-based resources and associated grid issues, synchronous condensers have become more common. The literature indicates a considerable gap in understanding the loss of synchronism phenomenon in synchronous condensers, particularly under conditions where inverter-based resources dominate the power grid. This thesis examines the loss of synchronism phenomenon in synchronous condensers, including theoretical analysis using phasor diagrams of realistic scenarios. It also investigates the distinction between loss of synchronism and the pole slipping phenomenon, which has led to failures in traditional impedance-based schemes. The proposed relative speed-based method is applied to synchronous condensers and its effectiveness is demonstrated in situations where traditional schemes have failed. Additionally, effectiveness of the proposed method in weak grids with a high penetration of inverter-based resources is analysed using a modified IEEE 39 bus system.","abstract_html":"The &quot;loss of synchronism&quot; condition in a synchronous machine is a critical state where the rotor fails to stay synchronized with the stator magnetic field. This can be caused by various factors, including system disturbances and power system instabilities. A machine undergoing a loss of synchronism may experiences torsional stresses, increased rotor iron currents and winding stresses in their mechanical systems. Synchronous machine loss of synchronism protection is employed to promptly disconnect a machine operating asynchronously to avoid damage or degradation. This thesis explores the loss of synchronism phenomenon in synchronous generators and introduces a novel loss of synchronism detection method based on the estimated relative speed of the rotor. The proposed algorithm utilizes readily available terminal voltage, current and machine parameters to estimate the rotor speed following a disturbance. It identifies loss of synchronism condition if the estimated relative speed tends to increase during a swing cycle. This method is computationally simple, easy to implement, and faster than impedance-based techniques under certain conditions. The sensitivity and security of this method is evaluated through time-domain simulations under various power system conditions. The performance of the proposed method is also compared against well established loss of synchronism protection schemes. The occurrence of loss of synchronism in synchronous condensers has not been extensively studied, primarily due to its rarity in traditional power systems. However, with the increasing integration of inverter-based resources and associated grid issues, synchronous condensers have become more common. The literature indicates a considerable gap in understanding the loss of synchronism phenomenon in synchronous condensers, particularly under conditions where inverter-based resources dominate the power grid. This thesis examines the loss of synchronism phenomenon in synchronous condensers, including theoretical analysis using phasor diagrams of realistic scenarios. It also investigates the distinction between loss of synchronism and the pole slipping phenomenon, which has led to failures in traditional impedance-based schemes. The proposed relative speed-based method is applied to synchronous condensers and its effectiveness is demonstrated in situations where traditional schemes have failed. Additionally, effectiveness of the proposed method in weak grids with a high penetration of inverter-based resources is analysed using a modified IEEE 39 bus system.","abstract_has_math":false,"creators":["Samarawickrama, Kasun Chamara"],"institution":null,"degree_name":null,"degree_level":"Doctor of Philosophy (Ph.D.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Rajapakse, Athula","Perera, Nuwan"],"committee_chairs":[],"committee_members":["Kordi, Behzad (Electrical and Computer Engineering)","Hollaender, Hartmut (Civil Engineering)","Tavares, Maria Cristina (University of Campinas)"],"year":2025,"date_issued":"2025-12-10","date_published":"2025-12-10","updated_at":"2026-11-19T09:07:05Z","subjects":["Out-of-step","Out-of-step protection","Loss of synchronism","Loss of synchronism protection","Pole slipping","Speed estimation","Angular instability","Power swing","Synchronous machines"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/39615","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/39615","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F39615","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F39615","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kordi, Behzad (Electrical and Computer Engineering)","Hollaender, Hartmut (Civil Engineering)","Tavares, Maria Cristina (University of Campinas)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Rajapakse, Athula","Perera, Nuwan"]},{"key":"dc:creator","label":"Author","values":["Samarawickrama, Kasun Chamara"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-01-22T15:35:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-01-22T15:35:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-12-10"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2026-01-06T05:48:27Z","2026-01-07T16:46:53Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Out-of-step","Out-of-step protection","Loss of synchronism","Loss of synchronism protection","Pole slipping","Speed estimation","Angular instability","Power swing","Synchronous machines"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/39615"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"crisitem:project.awardurl","label":"Crisitem Project Awardurl","values":["https://umanitoba.ca/engineering/electrical-and-computer-engineering/umgf"]},{"key":"crisitem:project.funder","label":"Crisitem Project Funder","values":["University of Manitoba"]},{"key":"crisitem:project.funderid","label":"Crisitem Project Funderid","values":["http://dx.doi.org/10.13039/100010318"]},{"key":"crisitem:project.title","label":"Crisitem Project Title","values":["University of Manitoba Graduate Fellowship"]},{"key":"dc:description.abstract","label":"Abstract","values":["The \"loss of synchronism\" condition in a synchronous machine is a critical state where the rotor fails to stay synchronized with the stator magnetic field. This can be caused by various factors, including system disturbances and power system instabilities. A machine undergoing a loss of synchronism may experiences torsional stresses, increased rotor iron currents and winding stresses in their mechanical systems. Synchronous machine loss of synchronism protection is employed to promptly disconnect a machine operating asynchronously to avoid damage or degradation. This thesis explores the loss of synchronism phenomenon in synchronous generators and introduces a novel loss of synchronism detection method based on the estimated relative speed of the rotor. The proposed algorithm utilizes readily available terminal voltage, current and machine parameters to estimate the rotor speed following a disturbance. It identifies loss of synchronism condition if the estimated relative speed tends to increase during a swing cycle. This method is computationally simple, easy to implement, and faster than impedance-based techniques under certain conditions. The sensitivity and security of this method is evaluated through time-domain simulations under various power system conditions. The performance of the proposed method is also compared against well established loss of synchronism protection schemes. The occurrence of loss of synchronism in synchronous condensers has not been extensively studied, primarily due to its rarity in traditional power systems. However, with the increasing integration of inverter-based resources and associated grid issues, synchronous condensers have become more common. The literature indicates a considerable gap in understanding the loss of synchronism phenomenon in synchronous condensers, particularly under conditions where inverter-based resources dominate the power grid. This thesis examines the loss of synchronism phenomenon in synchronous condensers, including theoretical analysis using phasor diagrams of realistic scenarios. It also investigates the distinction between loss of synchronism and the pole slipping phenomenon, which has led to failures in traditional impedance-based schemes. The proposed relative speed-based method is applied to synchronous condensers and its effectiveness is demonstrated in situations where traditional schemes have failed. Additionally, effectiveness of the proposed method in weak grids with a high penetration of inverter-based resources is analysed using a modified IEEE 39 bus system."]},{"key":"dc:description.note","label":"Dc Description Note","values":["February 2026"]},{"key":"dc:title","label":"Title","values":["Investigation of loss of synchronism phenomenon in synchronous machines and protection using trajectory of relative speed"]},{"key":"local:admin","label":"Local Admin","values":["yes"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"crisitem:project.awardurl":["https://umanitoba.ca/engineering/electrical-and-computer-engineering/umgf"],"crisitem:project.funder":["University of Manitoba"],"crisitem:project.funderid":["http://dx.doi.org/10.13039/100010318"],"crisitem:project.title":["University of Manitoba Graduate Fellowship"],"dc:contributor.committeemember":["Kordi, Behzad (Electrical and Computer Engineering)","Hollaender, Hartmut (Civil Engineering)","Tavares, Maria Cristina (University of Campinas)"],"dc:contributor.supervisor":["Rajapakse, Athula","Perera, Nuwan"],"dc:creator":["Samarawickrama, Kasun Chamara"],"dc:date.accessioned":["2026-01-22T15:35:42Z"],"dc:date.available":["2026-01-22T15:35:42Z"],"dc:date.issued":["2025-12-10"],"dc:date.submitted":["2026-01-06T05:48:27Z","2026-01-07T16:46:53Z"],"dc:description.abstract":["The \"loss of synchronism\" condition in a synchronous machine is a critical state where the rotor fails to stay synchronized with the stator magnetic field. This can be caused by various factors, including system disturbances and power system instabilities. A machine undergoing a loss of synchronism may experiences torsional stresses, increased rotor iron currents and winding stresses in their mechanical systems. Synchronous machine loss of synchronism protection is employed to promptly disconnect a machine operating asynchronously to avoid damage or degradation. This thesis explores the loss of synchronism phenomenon in synchronous generators and introduces a novel loss of synchronism detection method based on the estimated relative speed of the rotor. The proposed algorithm utilizes readily available terminal voltage, current and machine parameters to estimate the rotor speed following a disturbance. It identifies loss of synchronism condition if the estimated relative speed tends to increase during a swing cycle. This method is computationally simple, easy to implement, and faster than impedance-based techniques under certain conditions. The sensitivity and security of this method is evaluated through time-domain simulations under various power system conditions. The performance of the proposed method is also compared against well established loss of synchronism protection schemes. The occurrence of loss of synchronism in synchronous condensers has not been extensively studied, primarily due to its rarity in traditional power systems. However, with the increasing integration of inverter-based resources and associated grid issues, synchronous condensers have become more common. The literature indicates a considerable gap in understanding the loss of synchronism phenomenon in synchronous condensers, particularly under conditions where inverter-based resources dominate the power grid. This thesis examines the loss of synchronism phenomenon in synchronous condensers, including theoretical analysis using phasor diagrams of realistic scenarios. It also investigates the distinction between loss of synchronism and the pole slipping phenomenon, which has led to failures in traditional impedance-based schemes. The proposed relative speed-based method is applied to synchronous condensers and its effectiveness is demonstrated in situations where traditional schemes have failed. Additionally, effectiveness of the proposed method in weak grids with a high penetration of inverter-based resources is analysed using a modified IEEE 39 bus system."],"dc:description.note":["February 2026"],"dc:identifier.uri":["http://hdl.handle.net/1993/39615"],"dc:language.iso":["eng"],"dc:subject":["Out-of-step","Out-of-step protection","Loss of synchronism","Loss of synchronism protection","Pole slipping","Speed estimation","Angular instability","Power swing","Synchronous machines"],"dc:title":["Investigation of loss of synchronism phenomenon in synchronous machines and protection using trajectory of relative speed"],"local:admin":["yes"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T09:07:05Z"}