{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/39657"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/39657","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Evaluating, planning, and ranking of multi-infeed HVDC systems using unified control performance indices","abstract":"Modernizing multi-infeed HVDC corridors increasingly involves replacing aging line-commutated converters with voltage-sourced converters to improve controllability and fault resilience. However, conventional planning indices remain largely static and are often treated as separate metrics, making it difficult to consistently rank modernization options across a defined contingency set. This thesis proposes a streamlined screening method based on Control Performance Indices (CPIs) that summarizes post-fault recovery by penalizing deviation magnitude and persistence. The approach evaluates voltage, frequency, and DC power trajectories and organizes the results into a station-by-contingency CPI matrix. Structured aggregation produces an event-level index for ranking contingency severity, a station-level index for identifying vulnerable terminals, and system-level metrics for comparing alternatives through a reference benchmark. The framework is validated on a three-bipole Manitoba Hydro modernization scenario and yields consistent rankings across converter topologies, ratings, and control modes; among the cases studied, a higher-rated VSC–VSC configuration with inverter AC-voltage control delivers the most robust post-fault performance under the evaluated fault set. The method is further extended to low-voltage ride-through assessment by mapping fault duration and retained voltage to a capability surface and is implemented as a Python-based automation workflow to ensure repeatable, auditable planning studies.","abstract_html":"Modernizing multi-infeed HVDC corridors increasingly involves replacing aging line-commutated converters with voltage-sourced converters to improve controllability and fault resilience. However, conventional planning indices remain largely static and are often treated as separate metrics, making it difficult to consistently rank modernization options across a defined contingency set. This thesis proposes a streamlined screening method based on Control Performance Indices (CPIs) that summarizes post-fault recovery by penalizing deviation magnitude and persistence. The approach evaluates voltage, frequency, and DC power trajectories and organizes the results into a station-by-contingency CPI matrix. Structured aggregation produces an event-level index for ranking contingency severity, a station-level index for identifying vulnerable terminals, and system-level metrics for comparing alternatives through a reference benchmark. The framework is validated on a three-bipole Manitoba Hydro modernization scenario and yields consistent rankings across converter topologies, ratings, and control modes; among the cases studied, a higher-rated VSC–VSC configuration with inverter AC-voltage control delivers the most robust post-fault performance under the evaluated fault set. The method is further extended to low-voltage ride-through assessment by mapping fault duration and retained voltage to a capability surface and is implemented as a Python-based automation workflow to ensure repeatable, auditable planning studies.","abstract_has_math":false,"creators":["Jin, Keke"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Gole, Aniruddha"],"committee_chairs":[],"committee_members":["Fernando, Ioni (Electrical and Computer Engineering)","Filizadeh, Shaahin (Electrical and Computer Engineering)","Zhou, Jenny (Electrical and Computer Engineering)"],"year":2026,"date_issued":"2026-03-02","date_published":"2026-03-02","updated_at":"2026-11-19T09:06:04Z","subjects":["Multi-Infeed HVDC","Planning Screening Index","Power System Resilience","Voltage source converter","Control Performance","Power System Stability Boundary Assessment","Hybrid VSC LCC","Low Voltage Ride Through"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/39657","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/39657","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F39657","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F39657","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Fernando, Ioni (Electrical and Computer Engineering)","Filizadeh, Shaahin (Electrical and Computer Engineering)","Zhou, Jenny (Electrical and Computer Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Gole, Aniruddha"]},{"key":"dc:creator","label":"Author","values":["Jin, Keke"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-03-12T19:14:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-03-12T19:14:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-03-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2026-03-03T14:32:20Z","2026-03-12T18:48:43Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Multi-Infeed HVDC","Planning Screening Index","Power System Resilience","Voltage source converter","Control Performance","Power System Stability Boundary Assessment","Hybrid VSC LCC","Low Voltage Ride Through"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/39657"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"crisitem:project.funder","label":"Crisitem Project Funder","values":["Manitoba Hydro"]},{"key":"dc:description.abstract","label":"Abstract","values":["Modernizing multi-infeed HVDC corridors increasingly involves replacing aging line-commutated converters with voltage-sourced converters to improve controllability and fault resilience. However, conventional planning indices remain largely static and are often treated as separate metrics, making it difficult to consistently rank modernization options across a defined contingency set. This thesis proposes a streamlined screening method based on Control Performance Indices (CPIs) that summarizes post-fault recovery by penalizing deviation magnitude and persistence. The approach evaluates voltage, frequency, and DC power trajectories and organizes the results into a station-by-contingency CPI matrix. Structured aggregation produces an event-level index for ranking contingency severity, a station-level index for identifying vulnerable terminals, and system-level metrics for comparing alternatives through a reference benchmark. The framework is validated on a three-bipole Manitoba Hydro modernization scenario and yields consistent rankings across converter topologies, ratings, and control modes; among the cases studied, a higher-rated VSC–VSC configuration with inverter AC-voltage control delivers the most robust post-fault performance under the evaluated fault set. The method is further extended to low-voltage ride-through assessment by mapping fault duration and retained voltage to a capability surface and is implemented as a Python-based automation workflow to ensure repeatable, auditable planning studies."]},{"key":"dc:description.note","label":"Dc Description Note","values":["May 2026"]},{"key":"dc:title","label":"Title","values":["Evaluating, planning, and ranking of multi-infeed HVDC systems using unified control performance indices"]},{"key":"local:admin","label":"Local Admin","values":["no"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"crisitem:project.funder":["Manitoba Hydro"],"dc:contributor.committeemember":["Fernando, Ioni (Electrical and Computer Engineering)","Filizadeh, Shaahin (Electrical and Computer Engineering)","Zhou, Jenny (Electrical and Computer Engineering)"],"dc:contributor.supervisor":["Gole, Aniruddha"],"dc:creator":["Jin, Keke"],"dc:date.accessioned":["2026-03-12T19:14:21Z"],"dc:date.available":["2026-03-12T19:14:21Z"],"dc:date.issued":["2026-03-02"],"dc:date.submitted":["2026-03-03T14:32:20Z","2026-03-12T18:48:43Z"],"dc:description.abstract":["Modernizing multi-infeed HVDC corridors increasingly involves replacing aging line-commutated converters with voltage-sourced converters to improve controllability and fault resilience. However, conventional planning indices remain largely static and are often treated as separate metrics, making it difficult to consistently rank modernization options across a defined contingency set. This thesis proposes a streamlined screening method based on Control Performance Indices (CPIs) that summarizes post-fault recovery by penalizing deviation magnitude and persistence. The approach evaluates voltage, frequency, and DC power trajectories and organizes the results into a station-by-contingency CPI matrix. Structured aggregation produces an event-level index for ranking contingency severity, a station-level index for identifying vulnerable terminals, and system-level metrics for comparing alternatives through a reference benchmark. The framework is validated on a three-bipole Manitoba Hydro modernization scenario and yields consistent rankings across converter topologies, ratings, and control modes; among the cases studied, a higher-rated VSC–VSC configuration with inverter AC-voltage control delivers the most robust post-fault performance under the evaluated fault set. The method is further extended to low-voltage ride-through assessment by mapping fault duration and retained voltage to a capability surface and is implemented as a Python-based automation workflow to ensure repeatable, auditable planning studies."],"dc:description.note":["May 2026"],"dc:identifier.uri":["http://hdl.handle.net/1993/39657"],"dc:language.iso":["eng"],"dc:subject":["Multi-Infeed HVDC","Planning Screening Index","Power System Resilience","Voltage source converter","Control Performance","Power System Stability Boundary Assessment","Hybrid VSC LCC","Low Voltage Ride Through"],"dc:title":["Evaluating, planning, and ranking of multi-infeed HVDC systems using unified control performance indices"],"local:admin":["no"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:06:04Z"}