{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/39671"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/39671","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Design and monolithic 3D printing of a split-and-recombine micromixer and a microfluidic concentration gradient generator","abstract":"This thesis presents the design, fabrication, and validation of an integrated Microfluidic Concentration Gradient Generator (MCGG) tailored for automated protein analysis and compatible with Silver printed Surface-Enhanced Raman Spectroscopy (Ag P-SERS) substrates. The objective of this work is to develop a fully additively manufactured platform capable of handling microliter-scale protein samples, delivering reagents with high precision, and interfacing directly with on-chip Surface-Enhanced Raman Spectroscopy (SERS) detection modules. To achieve this, three device iterations were produced using stereolithography digital light processing (SLA DLP) 3D printing, allowing systematic evaluation of printability, fluidic behavior, mixing efficiency, and flow distribution across increasingly functional architectures. The first iteration established the baseline performance of the Split-andrecombine (SAR) micromixing units and the hydraulic resistor network responsible for gradient formation. Surface profilometry confirmed smooth channel walls with Ra ≈ 0.13 µm, and mixing experiments demonstrated >90% mixing efficiency across Reynolds numbers (Re) ranging from 0.1 to 100. Numerical simulations showed stable and predictable gradient formation, which was validated experimentally using Fluorescein isothiocyanate (FITC)-dextran fluorescence measurements. The second iteration incorporated a reducing-agent delivery module designed to introduce tris(2-carboxyethyl)phosphine (TCEP) at a controlled 2:1 volumetric ratio with the protein stream, enabling thiol exposure prior to SERS detection. COMSOL simulations confirmed the expected diluted concentration levels at the five outputs, and fluorescence and spectrophotometric experiments verified the accuracy and stability of the dilution module across all tested flow conditions. The third iteration integrated five sensing wells compatible with Ag P-SERS substrates, completing the automated workflow for sample preparation prior to Raman analysis. Experimental characterization showed uniform flow distribution among the wells (0.29–0.32 mL per channel), demonstrating that the device delivers consistent sample volumes for downstream detection. Although SERS measurements could not be completed within the scope of this work, the fully assembled platform is operational and ready for optical characterization by collaborating groups. Overall, this thesis demonstrates the feasibility and advantages of fully 3Dprinted microfluidic architectures for automated biochemical processing. The platform offers precise gradient generation, reagent handling, and modular integration, providing a foundation for future development of compact, rapid, and reproducible SERS-based protein analysis systems.","abstract_html":"This thesis presents the design, fabrication, and validation of an integrated Microfluidic Concentration Gradient Generator (MCGG) tailored for automated protein analysis and compatible with Silver printed Surface-Enhanced Raman Spectroscopy (Ag P-SERS) substrates. The objective of this work is to develop a fully additively manufactured platform capable of handling microliter-scale protein samples, delivering reagents with high precision, and interfacing directly with on-chip Surface-Enhanced Raman Spectroscopy (SERS) detection modules. To achieve this, three device iterations were produced using stereolithography digital light processing (SLA DLP) 3D printing, allowing systematic evaluation of printability, fluidic behavior, mixing efficiency, and flow distribution across increasingly functional architectures. The first iteration established the baseline performance of the Split-andrecombine (SAR) micromixing units and the hydraulic resistor network responsible for gradient formation. Surface profilometry confirmed smooth channel walls with Ra ≈ 0.13 µm, and mixing experiments demonstrated &gt;90% mixing efficiency across Reynolds numbers (Re) ranging from 0.1 to 100. Numerical simulations showed stable and predictable gradient formation, which was validated experimentally using Fluorescein isothiocyanate (FITC)-dextran fluorescence measurements. The second iteration incorporated a reducing-agent delivery module designed to introduce tris(2-carboxyethyl)phosphine (TCEP) at a controlled 2:1 volumetric ratio with the protein stream, enabling thiol exposure prior to SERS detection. COMSOL simulations confirmed the expected diluted concentration levels at the five outputs, and fluorescence and spectrophotometric experiments verified the accuracy and stability of the dilution module across all tested flow conditions. The third iteration integrated five sensing wells compatible with Ag P-SERS substrates, completing the automated workflow for sample preparation prior to Raman analysis. Experimental characterization showed uniform flow distribution among the wells (0.29–0.32 mL per channel), demonstrating that the device delivers consistent sample volumes for downstream detection. Although SERS measurements could not be completed within the scope of this work, the fully assembled platform is operational and ready for optical characterization by collaborating groups. Overall, this thesis demonstrates the feasibility and advantages of fully 3Dprinted microfluidic architectures for automated biochemical processing. The platform offers precise gradient generation, reagent handling, and modular integration, providing a foundation for future development of compact, rapid, and reproducible SERS-based protein analysis systems.","abstract_has_math":false,"creators":["Navarro Molina, Francisco"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Salimi, Elham","Paliwal, Jitendra"],"committee_chairs":[],"committee_members":["Lin, Francis (Physics and Astronomy)","Shafai, Cyrus (Electrical and Computer Engineering)"],"year":2027,"date_issued":"2027-03-17","date_published":"2027-03-17","updated_at":"2026-11-19T09:05:41Z","subjects":["Microfluidics","Lab-on-a-chip","Microfluidic Concentration Gradient Generator (MCGG)","Split-and-Recombine (SAR) micromixer","3D printing","SLA DLP (stereolithography digital light processing)","Protein analysis","Surface-Enhanced Raman Spectroscopy (SERS)","Ag P-SERS substrates"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/39671","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/39671","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F39671","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F39671","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lin, Francis (Physics and Astronomy)","Shafai, Cyrus (Electrical and Computer Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Salimi, Elham","Paliwal, Jitendra"]},{"key":"dc:creator","label":"Author","values":["Navarro Molina, Francisco"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-03-24T17:37:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-03-24T17:37:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2027-03-17"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2026-03-18T20:11:17Z","2026-03-24T17:07:46Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfluidics","Lab-on-a-chip","Microfluidic Concentration Gradient Generator (MCGG)","Split-and-Recombine (SAR) micromixer","3D printing","SLA DLP (stereolithography digital light processing)","Protein analysis","Surface-Enhanced Raman Spectroscopy (SERS)","Ag P-SERS substrates"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/39671"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"crisitem:project.funder","label":"Crisitem Project Funder","values":["Mitacs"]},{"key":"crisitem:project.funderid","label":"Crisitem Project Funderid","values":["501100004489"]},{"key":"crisitem:project.grantno","label":"Crisitem Project Grantno","values":["IT35887"]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the design, fabrication, and validation of an integrated Microfluidic Concentration Gradient Generator (MCGG) tailored for automated protein analysis and compatible with Silver printed Surface-Enhanced Raman Spectroscopy (Ag P-SERS) substrates. The objective of this work is to develop a fully additively manufactured platform capable of handling microliter-scale protein samples, delivering reagents with high precision, and interfacing directly with on-chip Surface-Enhanced Raman Spectroscopy (SERS) detection modules. To achieve this, three device iterations were produced using stereolithography digital light processing (SLA DLP) 3D printing, allowing systematic evaluation of printability, fluidic behavior, mixing efficiency, and flow distribution across increasingly functional architectures. The first iteration established the baseline performance of the Split-andrecombine (SAR) micromixing units and the hydraulic resistor network responsible for gradient formation. Surface profilometry confirmed smooth channel walls with Ra ≈ 0.13 µm, and mixing experiments demonstrated >90% mixing efficiency across Reynolds numbers (Re) ranging from 0.1 to 100. Numerical simulations showed stable and predictable gradient formation, which was validated experimentally using Fluorescein isothiocyanate (FITC)-dextran fluorescence measurements. The second iteration incorporated a reducing-agent delivery module designed to introduce tris(2-carboxyethyl)phosphine (TCEP) at a controlled 2:1 volumetric ratio with the protein stream, enabling thiol exposure prior to SERS detection. COMSOL simulations confirmed the expected diluted concentration levels at the five outputs, and fluorescence and spectrophotometric experiments verified the accuracy and stability of the dilution module across all tested flow conditions. The third iteration integrated five sensing wells compatible with Ag P-SERS substrates, completing the automated workflow for sample preparation prior to Raman analysis. Experimental characterization showed uniform flow distribution among the wells (0.29–0.32 mL per channel), demonstrating that the device delivers consistent sample volumes for downstream detection. Although SERS measurements could not be completed within the scope of this work, the fully assembled platform is operational and ready for optical characterization by collaborating groups. Overall, this thesis demonstrates the feasibility and advantages of fully 3Dprinted microfluidic architectures for automated biochemical processing. The platform offers precise gradient generation, reagent handling, and modular integration, providing a foundation for future development of compact, rapid, and reproducible SERS-based protein analysis systems."]},{"key":"dc:description.note","label":"Dc Description Note","values":["May 2026"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Saskatchewan Pulse Growers, 100013209 Canada Foundation for Innovation, 501100000196, 59100 Natural Sciences and Engineering Research Council of Canada, 501100000038, ALLRP 586312-23"]},{"key":"dc:title","label":"Title","values":["Design and monolithic 3D printing of a split-and-recombine micromixer and a microfluidic concentration gradient generator"]},{"key":"local:admin","label":"Local Admin","values":["no"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"crisitem:project.funder":["Mitacs"],"crisitem:project.funderid":["501100004489"],"crisitem:project.grantno":["IT35887"],"dc:contributor.committeemember":["Lin, Francis (Physics and Astronomy)","Shafai, Cyrus (Electrical and Computer Engineering)"],"dc:contributor.supervisor":["Salimi, Elham","Paliwal, Jitendra"],"dc:creator":["Navarro Molina, Francisco"],"dc:date.accessioned":["2026-03-24T17:37:18Z"],"dc:date.available":["2026-03-24T17:37:18Z"],"dc:date.issued":["2027-03-17"],"dc:date.submitted":["2026-03-18T20:11:17Z","2026-03-24T17:07:46Z"],"dc:description.abstract":["This thesis presents the design, fabrication, and validation of an integrated Microfluidic Concentration Gradient Generator (MCGG) tailored for automated protein analysis and compatible with Silver printed Surface-Enhanced Raman Spectroscopy (Ag P-SERS) substrates. The objective of this work is to develop a fully additively manufactured platform capable of handling microliter-scale protein samples, delivering reagents with high precision, and interfacing directly with on-chip Surface-Enhanced Raman Spectroscopy (SERS) detection modules. To achieve this, three device iterations were produced using stereolithography digital light processing (SLA DLP) 3D printing, allowing systematic evaluation of printability, fluidic behavior, mixing efficiency, and flow distribution across increasingly functional architectures. The first iteration established the baseline performance of the Split-andrecombine (SAR) micromixing units and the hydraulic resistor network responsible for gradient formation. Surface profilometry confirmed smooth channel walls with Ra ≈ 0.13 µm, and mixing experiments demonstrated >90% mixing efficiency across Reynolds numbers (Re) ranging from 0.1 to 100. Numerical simulations showed stable and predictable gradient formation, which was validated experimentally using Fluorescein isothiocyanate (FITC)-dextran fluorescence measurements. The second iteration incorporated a reducing-agent delivery module designed to introduce tris(2-carboxyethyl)phosphine (TCEP) at a controlled 2:1 volumetric ratio with the protein stream, enabling thiol exposure prior to SERS detection. COMSOL simulations confirmed the expected diluted concentration levels at the five outputs, and fluorescence and spectrophotometric experiments verified the accuracy and stability of the dilution module across all tested flow conditions. The third iteration integrated five sensing wells compatible with Ag P-SERS substrates, completing the automated workflow for sample preparation prior to Raman analysis. Experimental characterization showed uniform flow distribution among the wells (0.29–0.32 mL per channel), demonstrating that the device delivers consistent sample volumes for downstream detection. Although SERS measurements could not be completed within the scope of this work, the fully assembled platform is operational and ready for optical characterization by collaborating groups. Overall, this thesis demonstrates the feasibility and advantages of fully 3Dprinted microfluidic architectures for automated biochemical processing. The platform offers precise gradient generation, reagent handling, and modular integration, providing a foundation for future development of compact, rapid, and reproducible SERS-based protein analysis systems."],"dc:description.note":["May 2026"],"dc:description.sponsorship":["Saskatchewan Pulse Growers, 100013209 Canada Foundation for Innovation, 501100000196, 59100 Natural Sciences and Engineering Research Council of Canada, 501100000038, ALLRP 586312-23"],"dc:identifier.uri":["http://hdl.handle.net/1993/39671"],"dc:language.iso":["eng"],"dc:subject":["Microfluidics","Lab-on-a-chip","Microfluidic Concentration Gradient Generator (MCGG)","Split-and-Recombine (SAR) micromixer","3D printing","SLA DLP (stereolithography digital light processing)","Protein analysis","Surface-Enhanced Raman Spectroscopy (SERS)","Ag P-SERS substrates"],"dc:title":["Design and monolithic 3D printing of a split-and-recombine micromixer and a microfluidic concentration gradient generator"],"local:admin":["no"],"others:access_status":["embargo"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:05:41Z"}