{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/4008"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/4008","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Shear bond strengths of two new self-etching primers","abstract":"Purpose: To evaluate the in vitro shear bond strength (SBS) of orthodontic attachments using 2 self-etching primers (SEP): iBOND and G-Bond. Methods: 180 molars were randomly divided into 12 groups. Teeth were bonded with a stainless steel button using Transbond XT composite. The bonding agents were iBOND, G-Bond, Transbond Plus SEP and Transbond XT primer (control). SBS’s immediately, 24hours and 3months were measured with their Adhesive Remnant Index (ARI). Results: Transbond XT primer (11.22MPa) had a significantly higher immediate SBS than Transbond Plus SEP (5.32MPa), iBOND (6.69MPa) and G-Bond (8.30MPa). 24 hours, Transbond XT primer (16.65MPa) and Transbond Plus SEP (13.20MPa) had a significant increase in their SBS. No difference was observed at 3 months. ARI were significantly different between the groups at all time points. Conclusions: iBOND and G-Bond yielded sufficient SBS’s over the three time points that may be sufficient to withstand occlusal and light archwire forces.","abstract_html":"Purpose: To evaluate the in vitro shear bond strength (SBS) of orthodontic attachments using 2 self-etching primers (SEP): iBOND and G-Bond. Methods: 180 molars were randomly divided into 12 groups. Teeth were bonded with a stainless steel button using Transbond XT composite. The bonding agents were iBOND, G-Bond, Transbond Plus SEP and Transbond XT primer (control). SBS’s immediately, 24hours and 3months were measured with their Adhesive Remnant Index (ARI). Results: Transbond XT primer (11.22MPa) had a significantly higher immediate SBS than Transbond Plus SEP (5.32MPa), iBOND (6.69MPa) and G-Bond (8.30MPa). 24 hours, Transbond XT primer (16.65MPa) and Transbond Plus SEP (13.20MPa) had a significant increase in their SBS. No difference was observed at 3 months. ARI were significantly different between the groups at all time points. Conclusions: iBOND and G-Bond yielded sufficient SBS’s over the three time points that may be sufficient to withstand occlusal and light archwire forces.","abstract_has_math":false,"creators":["Ho, Andy CS"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Preventive Dental Science","degree_department":null,"school":null,"contributors":[],"advisors":["Akyalcin, Sercan (Preventive Dental Science)"],"committee_chairs":[],"committee_members":["Swain, Vanessa (Restorative Dentistry)","Wiltshire, William (Preventive Dental Science)"],"year":2010,"date_issued":"2010-06-25T13:08:46Z","date_published":"2010-06-25T13:08:46Z","updated_at":"2026-11-19T09:06:21Z","subjects":["Orthodontics"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/4008","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/4008","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F4008","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F4008","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Swain, Vanessa (Restorative Dentistry)","Wiltshire, William (Preventive Dental Science)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Akyalcin, Sercan (Preventive Dental Science)"]},{"key":"dc:creator","label":"Author","values":["Ho, Andy CS"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-06-25T13:08:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-06-25T13:08:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-06-25T13:08:46Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Preventive Dental Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Orthodontics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/4008"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Purpose: To evaluate the in vitro shear bond strength (SBS) of orthodontic attachments using 2 self-etching primers (SEP): iBOND and G-Bond. Methods: 180 molars were randomly divided into 12 groups. Teeth were bonded with a stainless steel button using Transbond XT composite. The bonding agents were iBOND, G-Bond, Transbond Plus SEP and Transbond XT primer (control). SBS’s immediately, 24hours and 3months were measured with their Adhesive Remnant Index (ARI). Results: Transbond XT primer (11.22MPa) had a significantly higher immediate SBS than Transbond Plus SEP (5.32MPa), iBOND (6.69MPa) and G-Bond (8.30MPa). 24 hours, Transbond XT primer (16.65MPa) and Transbond Plus SEP (13.20MPa) had a significant increase in their SBS. No difference was observed at 3 months. ARI were significantly different between the groups at all time points. Conclusions: iBOND and G-Bond yielded sufficient SBS’s over the three time points that may be sufficient to withstand occlusal and light archwire forces."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2010"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1224328 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Shear bond strengths of two new self-etching primers"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Swain, Vanessa (Restorative Dentistry)","Wiltshire, William (Preventive Dental Science)"],"dc:contributor.supervisor":["Akyalcin, Sercan (Preventive Dental Science)"],"dc:creator":["Ho, Andy CS"],"dc:date.accessioned":["2010-06-25T13:08:46Z"],"dc:date.available":["2010-06-25T13:08:46Z"],"dc:date.issued":["2010-06-25T13:08:46Z"],"dc:description.abstract":["Purpose: To evaluate the in vitro shear bond strength (SBS) of orthodontic attachments using 2 self-etching primers (SEP): iBOND and G-Bond. Methods: 180 molars were randomly divided into 12 groups. Teeth were bonded with a stainless steel button using Transbond XT composite. The bonding agents were iBOND, G-Bond, Transbond Plus SEP and Transbond XT primer (control). SBS’s immediately, 24hours and 3months were measured with their Adhesive Remnant Index (ARI). Results: Transbond XT primer (11.22MPa) had a significantly higher immediate SBS than Transbond Plus SEP (5.32MPa), iBOND (6.69MPa) and G-Bond (8.30MPa). 24 hours, Transbond XT primer (16.65MPa) and Transbond Plus SEP (13.20MPa) had a significant increase in their SBS. No difference was observed at 3 months. ARI were significantly different between the groups at all time points. Conclusions: iBOND and G-Bond yielded sufficient SBS’s over the three time points that may be sufficient to withstand occlusal and light archwire forces."],"dc:description.note":["October 2010"],"dc:format.extent":["1224328 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1993/4008"],"dc:language.iso":["eng"],"dc:subject":["Orthodontics"],"dc:title":["Shear bond strengths of two new self-etching primers"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Preventive Dental Science"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:06:21Z"}