{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/40211"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/40211","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Impact of hydraulic faults on wind turbine pitch control performance: a systematic sensitivity analysis","abstract":"The pitch control system of wind turbine blades plays a critical role in both maximizing energy capture and protecting the turbine from aerodynamic overloading under severe wind conditions. Failures in the pitch control system account for approximately 20% of total turbine downtime. This research presents a sensitivity analysis approach to evaluate the performance degradation of a wind turbine hydraulic pitch control system under various component degradation and failure conditions, establishing performance-based fault severity levels that can support condition monitoring and maintenance prioritization. These levels characterize degradation in pitch-tracking performance, while practical intervention decisions must also consider fluid loss, pressure collapse, cavitation, and emergency-shutdown capability. A simulation model is developed in MATLAB/Simulink using Simscape to evaluate hydraulic system performance under representative wind loading. A regenerative benchmark hydraulic pitch control system is adopted. Blade pitch is regulated by a fixed-gain proportional-integral (PI) controller, held constant across all fault cases to isolate the effect of each fault. The aerodynamic loads applied to the blade-pitch actuator are obtained from OpenFAST at the rated wind speed, which represents the most demanding loading condition. The prescribed pitch-angle commands are applied to evaluate holding and maneuvering performance. The analysis systematically investigates the following fault scenarios: cylinder internal and external leakage, accumulator gas and fluid leakage, loss of pump volumetric efficiency, degraded valve performance due to solenoid response, valve internal leakage, and a reduction in the effective bulk modulus of the hydraulic oil. System sensitivity is quantified using the Integral of Absolute Error (IAE) and the Integral of Squared Error (ISE) of the blade pitch tracking error, normalized against the fault-free response. On this basis, the quantitatively evaluated fault cases are classified, where applicable, as minor, moderate, severe, or unacceptable according to the growth of their normalized IAE. The results show that the severity of a fault depends not only on its type and magnitude but also on its location within the circuit, and that faults which directly reduce control authority are the most critical ones. Together with fault-specific hydraulic and operational indicators, this classification provides practical guidance for condition monitoring, maintenance prioritization, and hydraulic-system design.","abstract_html":"The pitch control system of wind turbine blades plays a critical role in both maximizing energy capture and protecting the turbine from aerodynamic overloading under severe wind conditions. Failures in the pitch control system account for approximately 20% of total turbine downtime. This research presents a sensitivity analysis approach to evaluate the performance degradation of a wind turbine hydraulic pitch control system under various component degradation and failure conditions, establishing performance-based fault severity levels that can support condition monitoring and maintenance prioritization. These levels characterize degradation in pitch-tracking performance, while practical intervention decisions must also consider fluid loss, pressure collapse, cavitation, and emergency-shutdown capability. A simulation model is developed in MATLAB/Simulink using Simscape to evaluate hydraulic system performance under representative wind loading. A regenerative benchmark hydraulic pitch control system is adopted. Blade pitch is regulated by a fixed-gain proportional-integral (PI) controller, held constant across all fault cases to isolate the effect of each fault. The aerodynamic loads applied to the blade-pitch actuator are obtained from OpenFAST at the rated wind speed, which represents the most demanding loading condition. The prescribed pitch-angle commands are applied to evaluate holding and maneuvering performance. The analysis systematically investigates the following fault scenarios: cylinder internal and external leakage, accumulator gas and fluid leakage, loss of pump volumetric efficiency, degraded valve performance due to solenoid response, valve internal leakage, and a reduction in the effective bulk modulus of the hydraulic oil. System sensitivity is quantified using the Integral of Absolute Error (IAE) and the Integral of Squared Error (ISE) of the blade pitch tracking error, normalized against the fault-free response. On this basis, the quantitatively evaluated fault cases are classified, where applicable, as minor, moderate, severe, or unacceptable according to the growth of their normalized IAE. The results show that the severity of a fault depends not only on its type and magnitude but also on its location within the circuit, and that faults which directly reduce control authority are the most critical ones. Together with fault-specific hydraulic and operational indicators, this classification provides practical guidance for condition monitoring, maintenance prioritization, and hydraulic-system design.","abstract_has_math":false,"creators":["Zhang, Jichao"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Sepehri, Nariman"],"committee_chairs":[],"committee_members":["Peng, Qingjin (Mechanical Engineering)","Liang, Xihui (Mechanical Engineering)"],"year":2026,"date_issued":"2026-11-16","date_published":"2026-11-16","updated_at":"2026-11-21T09:51:37Z","subjects":["Wind turbine pitch control","Hydraulic systems","Fault sensitivity analysis","Simscape modeling","NREL 5-MW reference wind turbine","OpenFAST"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/40211","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/40211","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F40211","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F40211","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Peng, Qingjin (Mechanical Engineering)","Liang, Xihui (Mechanical Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Sepehri, Nariman"]},{"key":"dc:creator","label":"Author","values":["Zhang, Jichao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-11-19T14:03:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-11-19T14:03:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-11-16"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2026-11-17T03:55:55Z","2026-11-19T00:11:07Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Wind turbine pitch control","Hydraulic systems","Fault sensitivity analysis","Simscape modeling","NREL 5-MW reference wind turbine","OpenFAST"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/40211"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The pitch control system of wind turbine blades plays a critical role in both maximizing energy capture and protecting the turbine from aerodynamic overloading under severe wind conditions. Failures in the pitch control system account for approximately 20% of total turbine downtime. This research presents a sensitivity analysis approach to evaluate the performance degradation of a wind turbine hydraulic pitch control system under various component degradation and failure conditions, establishing performance-based fault severity levels that can support condition monitoring and maintenance prioritization. These levels characterize degradation in pitch-tracking performance, while practical intervention decisions must also consider fluid loss, pressure collapse, cavitation, and emergency-shutdown capability. A simulation model is developed in MATLAB/Simulink using Simscape to evaluate hydraulic system performance under representative wind loading. A regenerative benchmark hydraulic pitch control system is adopted. Blade pitch is regulated by a fixed-gain proportional-integral (PI) controller, held constant across all fault cases to isolate the effect of each fault. The aerodynamic loads applied to the blade-pitch actuator are obtained from OpenFAST at the rated wind speed, which represents the most demanding loading condition. The prescribed pitch-angle commands are applied to evaluate holding and maneuvering performance. The analysis systematically investigates the following fault scenarios: cylinder internal and external leakage, accumulator gas and fluid leakage, loss of pump volumetric efficiency, degraded valve performance due to solenoid response, valve internal leakage, and a reduction in the effective bulk modulus of the hydraulic oil. System sensitivity is quantified using the Integral of Absolute Error (IAE) and the Integral of Squared Error (ISE) of the blade pitch tracking error, normalized against the fault-free response. On this basis, the quantitatively evaluated fault cases are classified, where applicable, as minor, moderate, severe, or unacceptable according to the growth of their normalized IAE. The results show that the severity of a fault depends not only on its type and magnitude but also on its location within the circuit, and that faults which directly reduce control authority are the most critical ones. Together with fault-specific hydraulic and operational indicators, this classification provides practical guidance for condition monitoring, maintenance prioritization, and hydraulic-system design."]},{"key":"dc:description.note","label":"Dc Description Note","values":["February 2027"]},{"key":"dc:title","label":"Title","values":["Impact of hydraulic faults on wind turbine pitch control performance: a systematic sensitivity analysis"]},{"key":"local:admin","label":"Local Admin","values":["yes"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Peng, Qingjin (Mechanical Engineering)","Liang, Xihui (Mechanical Engineering)"],"dc:contributor.supervisor":["Sepehri, Nariman"],"dc:creator":["Zhang, Jichao"],"dc:date.accessioned":["2026-11-19T14:03:29Z"],"dc:date.available":["2026-11-19T14:03:29Z"],"dc:date.issued":["2026-11-16"],"dc:date.submitted":["2026-11-17T03:55:55Z","2026-11-19T00:11:07Z"],"dc:description.abstract":["The pitch control system of wind turbine blades plays a critical role in both maximizing energy capture and protecting the turbine from aerodynamic overloading under severe wind conditions. Failures in the pitch control system account for approximately 20% of total turbine downtime. This research presents a sensitivity analysis approach to evaluate the performance degradation of a wind turbine hydraulic pitch control system under various component degradation and failure conditions, establishing performance-based fault severity levels that can support condition monitoring and maintenance prioritization. These levels characterize degradation in pitch-tracking performance, while practical intervention decisions must also consider fluid loss, pressure collapse, cavitation, and emergency-shutdown capability. A simulation model is developed in MATLAB/Simulink using Simscape to evaluate hydraulic system performance under representative wind loading. A regenerative benchmark hydraulic pitch control system is adopted. Blade pitch is regulated by a fixed-gain proportional-integral (PI) controller, held constant across all fault cases to isolate the effect of each fault. The aerodynamic loads applied to the blade-pitch actuator are obtained from OpenFAST at the rated wind speed, which represents the most demanding loading condition. The prescribed pitch-angle commands are applied to evaluate holding and maneuvering performance. The analysis systematically investigates the following fault scenarios: cylinder internal and external leakage, accumulator gas and fluid leakage, loss of pump volumetric efficiency, degraded valve performance due to solenoid response, valve internal leakage, and a reduction in the effective bulk modulus of the hydraulic oil. System sensitivity is quantified using the Integral of Absolute Error (IAE) and the Integral of Squared Error (ISE) of the blade pitch tracking error, normalized against the fault-free response. On this basis, the quantitatively evaluated fault cases are classified, where applicable, as minor, moderate, severe, or unacceptable according to the growth of their normalized IAE. The results show that the severity of a fault depends not only on its type and magnitude but also on its location within the circuit, and that faults which directly reduce control authority are the most critical ones. Together with fault-specific hydraulic and operational indicators, this classification provides practical guidance for condition monitoring, maintenance prioritization, and hydraulic-system design."],"dc:description.note":["February 2027"],"dc:identifier.uri":["http://hdl.handle.net/1993/40211"],"dc:language.iso":["eng"],"dc:subject":["Wind turbine pitch control","Hydraulic systems","Fault sensitivity analysis","Simscape modeling","NREL 5-MW reference wind turbine","OpenFAST"],"dc:title":["Impact of hydraulic faults on wind turbine pitch control performance: a systematic sensitivity analysis"],"local:admin":["yes"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-21T09:51:37Z"}