{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/40216"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/40216","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"CFD analysis of condensation from a ternary gas mixture","abstract":"This thesis investigates computational fluid dynamics (CFD) modeling of wall condensation and multicomponent gas stratification in steam-air and steam-air-helium mixtures for geometries relevant to nuclear containment passive cooling systems. Computational models in the commercial CFD code ANSYS Fluent were benchmarked against the CONAN and Strong Condensation Cavity Apparatus (SCCA) experiments. Validation against the CONAN channel experiment established the proportional wall species boundary condition as adequate provided the wall-adjacent mesh is refined with y+≈1. Forced convection heat flux and condensation rates were well predicted, but natural convection cases proved sensitive to test geometry and flow reversal conditions. The Full Multicomponent (FM) species diffusion model was required to adequately predict flow reversal due to light gas accumulation near the condensing wall for natural convection regimes. SCCA benchmarking for six binary steam-air cases demonstrated that while steady-state steam-air stratification is accurately captured, solution temperatures are highly sensitive to wall emissivities, requiring high emissivity values (≥0.8) to avoid temperature overprediction. Integrating a fog transport and bulk phase change model confirmed the presence of an evaporative aerosol barrier at the stratified interface. When extended to ternary cases, neither RANS nor URANS formulations preserved mixture stratification, instead predicting a homogenized cavity—a limitation also found in the historical THAI ISP-47 ternary gas containment benchmark. Analysis revealed that homogenization progresses via interface erosion and helium dilution of the air-rich lower region, the latter likely driven by a lower-region thermal overprediction from incorrect heated-wall plume behaviour. While unsteady simulations captured a transient plateau where interface erosion ceased, helium advection into the stagnant region continued uninhibited. Consequently, resolving this experimentally inconsistent helium advection represents a critical requirement to achieving accurate steady-state stratification in multi-component containment simulations.","abstract_html":"This thesis investigates computational fluid dynamics (CFD) modeling of wall condensation and multicomponent gas stratification in steam-air and steam-air-helium mixtures for geometries relevant to nuclear containment passive cooling systems. Computational models in the commercial CFD code ANSYS Fluent were benchmarked against the CONAN and Strong Condensation Cavity Apparatus (SCCA) experiments. Validation against the CONAN channel experiment established the proportional wall species boundary condition as adequate provided the wall-adjacent mesh is refined with y+≈1. Forced convection heat flux and condensation rates were well predicted, but natural convection cases proved sensitive to test geometry and flow reversal conditions. The Full Multicomponent (FM) species diffusion model was required to adequately predict flow reversal due to light gas accumulation near the condensing wall for natural convection regimes. SCCA benchmarking for six binary steam-air cases demonstrated that while steady-state steam-air stratification is accurately captured, solution temperatures are highly sensitive to wall emissivities, requiring high emissivity values (≥0.8) to avoid temperature overprediction. Integrating a fog transport and bulk phase change model confirmed the presence of an evaporative aerosol barrier at the stratified interface. When extended to ternary cases, neither RANS nor URANS formulations preserved mixture stratification, instead predicting a homogenized cavity—a limitation also found in the historical THAI ISP-47 ternary gas containment benchmark. Analysis revealed that homogenization progresses via interface erosion and helium dilution of the air-rich lower region, the latter likely driven by a lower-region thermal overprediction from incorrect heated-wall plume behaviour. While unsteady simulations captured a transient plateau where interface erosion ceased, helium advection into the stagnant region continued uninhibited. Consequently, resolving this experimentally inconsistent helium advection represents a critical requirement to achieving accurate steady-state stratification in multi-component containment simulations.","abstract_has_math":false,"creators":["Rempel, Bronwyn"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Ormiston, Scott"],"committee_chairs":[],"committee_members":["Tachie, Mark (Mechanical Engineering)","Dow, Karen (Civil Engineering)"],"year":2026,"date_issued":"2026-11-24","date_published":"2026-11-24","updated_at":"2026-11-27T09:56:21Z","subjects":["CFD","condensation","ternary","nuclear"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/40216","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/40216","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F40216","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F40216","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Tachie, Mark (Mechanical Engineering)","Dow, Karen (Civil Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Ormiston, Scott"]},{"key":"dc:creator","label":"Author","values":["Rempel, Bronwyn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-11-25T14:19:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-11-25T14:19:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-11-24"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2026-11-25T02:33:11Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CFD","condensation","ternary","nuclear"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/40216"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"crisitem:project.funder","label":"Crisitem Project Funder","values":["Canadian Nuclear Laboratories"]},{"key":"crisitem:project.funderid","label":"Crisitem Project Funderid","values":["501100020722"]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis investigates computational fluid dynamics (CFD) modeling of wall condensation and multicomponent gas stratification in steam-air and steam-air-helium mixtures for geometries relevant to nuclear containment passive cooling systems. Computational models in the commercial CFD code ANSYS Fluent were benchmarked against the CONAN and Strong Condensation Cavity Apparatus (SCCA) experiments. Validation against the CONAN channel experiment established the proportional wall species boundary condition as adequate provided the wall-adjacent mesh is refined with y+≈1. Forced convection heat flux and condensation rates were well predicted, but natural convection cases proved sensitive to test geometry and flow reversal conditions. The Full Multicomponent (FM) species diffusion model was required to adequately predict flow reversal due to light gas accumulation near the condensing wall for natural convection regimes. SCCA benchmarking for six binary steam-air cases demonstrated that while steady-state steam-air stratification is accurately captured, solution temperatures are highly sensitive to wall emissivities, requiring high emissivity values (≥0.8) to avoid temperature overprediction. Integrating a fog transport and bulk phase change model confirmed the presence of an evaporative aerosol barrier at the stratified interface. When extended to ternary cases, neither RANS nor URANS formulations preserved mixture stratification, instead predicting a homogenized cavity—a limitation also found in the historical THAI ISP-47 ternary gas containment benchmark. Analysis revealed that homogenization progresses via interface erosion and helium dilution of the air-rich lower region, the latter likely driven by a lower-region thermal overprediction from incorrect heated-wall plume behaviour. While unsteady simulations captured a transient plateau where interface erosion ceased, helium advection into the stagnant region continued uninhibited. Consequently, resolving this experimentally inconsistent helium advection represents a critical requirement to achieving accurate steady-state stratification in multi-component containment simulations."]},{"key":"dc:description.note","label":"Dc Description Note","values":["February 2027"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["NSERC (Canada Graduate Research Scholarship - Master's program), MITACS"]},{"key":"dc:title","label":"Title","values":["CFD analysis of condensation from a ternary gas mixture"]},{"key":"local:admin","label":"Local Admin","values":["no"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"crisitem:project.funder":["Canadian Nuclear Laboratories"],"crisitem:project.funderid":["501100020722"],"dc:contributor.committeemember":["Tachie, Mark (Mechanical Engineering)","Dow, Karen (Civil Engineering)"],"dc:contributor.supervisor":["Ormiston, Scott"],"dc:creator":["Rempel, Bronwyn"],"dc:date.accessioned":["2026-11-25T14:19:34Z"],"dc:date.available":["2026-11-25T14:19:34Z"],"dc:date.issued":["2026-11-24"],"dc:date.submitted":["2026-11-25T02:33:11Z"],"dc:description.abstract":["This thesis investigates computational fluid dynamics (CFD) modeling of wall condensation and multicomponent gas stratification in steam-air and steam-air-helium mixtures for geometries relevant to nuclear containment passive cooling systems. Computational models in the commercial CFD code ANSYS Fluent were benchmarked against the CONAN and Strong Condensation Cavity Apparatus (SCCA) experiments. Validation against the CONAN channel experiment established the proportional wall species boundary condition as adequate provided the wall-adjacent mesh is refined with y+≈1. Forced convection heat flux and condensation rates were well predicted, but natural convection cases proved sensitive to test geometry and flow reversal conditions. The Full Multicomponent (FM) species diffusion model was required to adequately predict flow reversal due to light gas accumulation near the condensing wall for natural convection regimes. SCCA benchmarking for six binary steam-air cases demonstrated that while steady-state steam-air stratification is accurately captured, solution temperatures are highly sensitive to wall emissivities, requiring high emissivity values (≥0.8) to avoid temperature overprediction. Integrating a fog transport and bulk phase change model confirmed the presence of an evaporative aerosol barrier at the stratified interface. When extended to ternary cases, neither RANS nor URANS formulations preserved mixture stratification, instead predicting a homogenized cavity—a limitation also found in the historical THAI ISP-47 ternary gas containment benchmark. Analysis revealed that homogenization progresses via interface erosion and helium dilution of the air-rich lower region, the latter likely driven by a lower-region thermal overprediction from incorrect heated-wall plume behaviour. While unsteady simulations captured a transient plateau where interface erosion ceased, helium advection into the stagnant region continued uninhibited. Consequently, resolving this experimentally inconsistent helium advection represents a critical requirement to achieving accurate steady-state stratification in multi-component containment simulations."],"dc:description.note":["February 2027"],"dc:description.sponsorship":["NSERC (Canada Graduate Research Scholarship - Master's program), MITACS"],"dc:identifier.uri":["http://hdl.handle.net/1993/40216"],"dc:language.iso":["eng"],"dc:subject":["CFD","condensation","ternary","nuclear"],"dc:title":["CFD analysis of condensation from a ternary gas mixture"],"local:admin":["no"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-27T09:56:21Z"}