{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/4027"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/4027","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Phase Sensitive Interrogation of a RF Nanostrain Resonator for Structrual Health Monitoring Sensing Applications","abstract":"The purpose of this study was to design a passive nanostrain Radio Frequency strain sensor that helps to monitor the strain changes caused by traffic in motion on bridges. The phase sensitive interrogation method was applied meaning that the strain changes will be measured by the cavity sensor phase shift. The results revealed that the RF strain sensor could achieve a resolution of a few nanostrain. The principle conclusion was that the designed RF strain sensor has nanostrain sensitivity. Coaxial-Cylinder sensor sensitivity was 8 nanostrain. Cylinder volume resonant cavity sensor sensitivity was 8 nanostrain for high Q and 4 nanostrain for low Q. (BW = 160Hz) These sensitivities were somewhat larger than theoretical estimates due to noise from sauces other than the thermal noise used in the theoretical estimation. Therefore sensors will be useful for Structural Health Monitoring applications.","abstract_html":"The purpose of this study was to design a passive nanostrain Radio Frequency strain sensor that helps to monitor the strain changes caused by traffic in motion on bridges. The phase sensitive interrogation method was applied meaning that the strain changes will be measured by the cavity sensor phase shift. The results revealed that the RF strain sensor could achieve a resolution of a few nanostrain. The principle conclusion was that the designed RF strain sensor has nanostrain sensitivity. Coaxial-Cylinder sensor sensitivity was 8 nanostrain. Cylinder volume resonant cavity sensor sensitivity was 8 nanostrain for high Q and 4 nanostrain for low Q. (BW = 160Hz) These sensitivities were somewhat larger than theoretical estimates due to noise from sauces other than the thermal noise used in the theoretical estimation. Therefore sensors will be useful for Structural Health Monitoring applications.","abstract_has_math":false,"creators":["Meng, Rui"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Thomson, Douglas (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":["McNeill, Dean (Electrical and Computer Engineering)","Mufti, Aftab (Civil Engineering)"],"year":2010,"date_issued":"2010-07-15T21:39:09Z","date_published":"2010-07-15T21:39:09Z","updated_at":"2026-11-19T09:07:39Z","subjects":["RF","Nanostrain","Sensor","SHM"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/4027","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/4027","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F4027","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F4027","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["McNeill, Dean (Electrical and Computer Engineering)","Mufti, Aftab (Civil Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Thomson, Douglas (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Meng, Rui"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-07-15T21:39:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-07-15T21:39:09Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-07-15T21:39:09Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["RF","Nanostrain","Sensor","SHM"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/4027"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was to design a passive nanostrain Radio Frequency strain sensor that helps to monitor the strain changes caused by traffic in motion on bridges. The phase sensitive interrogation method was applied meaning that the strain changes will be measured by the cavity sensor phase shift. The results revealed that the RF strain sensor could achieve a resolution of a few nanostrain. The principle conclusion was that the designed RF strain sensor has nanostrain sensitivity. Coaxial-Cylinder sensor sensitivity was 8 nanostrain. Cylinder volume resonant cavity sensor sensitivity was 8 nanostrain for high Q and 4 nanostrain for low Q. (BW = 160Hz) These sensitivities were somewhat larger than theoretical estimates due to noise from sauces other than the thermal noise used in the theoretical estimation. Therefore sensors will be useful for Structural Health Monitoring applications."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2010"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["16080392 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Phase Sensitive Interrogation of a RF Nanostrain Resonator for Structrual Health Monitoring Sensing Applications"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["McNeill, Dean (Electrical and Computer Engineering)","Mufti, Aftab (Civil Engineering)"],"dc:contributor.supervisor":["Thomson, Douglas (Electrical and Computer Engineering)"],"dc:creator":["Meng, Rui"],"dc:date.accessioned":["2010-07-15T21:39:09Z"],"dc:date.available":["2010-07-15T21:39:09Z"],"dc:date.issued":["2010-07-15T21:39:09Z"],"dc:description.abstract":["The purpose of this study was to design a passive nanostrain Radio Frequency strain sensor that helps to monitor the strain changes caused by traffic in motion on bridges. The phase sensitive interrogation method was applied meaning that the strain changes will be measured by the cavity sensor phase shift. The results revealed that the RF strain sensor could achieve a resolution of a few nanostrain. The principle conclusion was that the designed RF strain sensor has nanostrain sensitivity. Coaxial-Cylinder sensor sensitivity was 8 nanostrain. Cylinder volume resonant cavity sensor sensitivity was 8 nanostrain for high Q and 4 nanostrain for low Q. (BW = 160Hz) These sensitivities were somewhat larger than theoretical estimates due to noise from sauces other than the thermal noise used in the theoretical estimation. Therefore sensors will be useful for Structural Health Monitoring applications."],"dc:description.note":["October 2010"],"dc:format.extent":["16080392 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1993/4027"],"dc:language.iso":["eng"],"dc:subject":["RF","Nanostrain","Sensor","SHM"],"dc:title":["Phase Sensitive Interrogation of a RF Nanostrain Resonator for Structrual Health Monitoring Sensing Applications"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:07:39Z"}