{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/4153"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/4153","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Measurement of the efficiency of evacuated tube solar collectors under various operating conditions","abstract":"The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. The scope of the research project was limited to the efficiency of a single tube, and various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% in general between the different collector configurations.","abstract_html":"The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. The scope of the research project was limited to the efficiency of a single tube, and various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% in general between the different collector configurations.","abstract_has_math":false,"creators":["Zubriski, Stephanie Erin"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Biosystems Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Dick, Kris (Biosystems Engineering)"],"committee_chairs":[],"committee_members":["Britton, M.G. (Ron) (Biosystems Engineering)","Blatz, James (Civil Engineering)"],"year":2010,"date_issued":"2010-09-10T22:38:11Z","date_published":"2010-09-10T22:38:11Z","updated_at":"2026-11-19T09:13:20Z","subjects":["Solar collector","Evacuated tube"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/4153","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/4153","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F4153","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F4153","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Britton, M.G. (Ron) (Biosystems Engineering)","Blatz, James (Civil Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Dick, Kris (Biosystems Engineering)"]},{"key":"dc:creator","label":"Author","values":["Zubriski, Stephanie Erin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-09-10T22:38:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-09-10T22:38:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-09-10T22:38:11Z"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biosystems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Solar collector","Evacuated tube"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/4153"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. The scope of the research project was limited to the efficiency of a single tube, and various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% in general between the different collector configurations."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2010"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["46828332 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Measurement of the efficiency of evacuated tube solar collectors under various operating conditions"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Britton, M.G. (Ron) (Biosystems Engineering)","Blatz, James (Civil Engineering)"],"dc:contributor.supervisor":["Dick, Kris (Biosystems Engineering)"],"dc:creator":["Zubriski, Stephanie Erin"],"dc:date.accessioned":["2010-09-10T22:38:11Z"],"dc:date.available":["2010-09-10T22:38:11Z"],"dc:date.issued":["2010-09-10T22:38:11Z"],"dc:description.abstract":["The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. The scope of the research project was limited to the efficiency of a single tube, and various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% in general between the different collector configurations."],"dc:description.note":["October 2010"],"dc:format.extent":["46828332 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1993/4153"],"dc:language.iso":["eng"],"dc:subject":["Solar collector","Evacuated tube"],"dc:title":["Measurement of the efficiency of evacuated tube solar collectors under various operating conditions"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biosystems Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:13:20Z"}