{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/4382"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/4382","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Emission and dispersion of odour from swine operations","abstract":"Odour emissions and instantaneous downwind odour plumes were measured on two 3000-sow swine farrowing farms located in a flat area of southern Manitoba, one farm (Farm A) with open earthen manure storage (EMS) and another (Farm B) with negative air pressure (NAP) covered EMS. Three commonly used dispersion models (ISCST3, AUSPLUME, and INPUFF-2) were used to predict downwind odour distributions on the two farms. Dispersion predictions were based on the measured odour emission data for each farm and on-site weather data recorded by a portable weather station. The peak-to-mean ratios of downwind odour intensity were computed from field odour intensity measurements and analysed against averaging time, downwind distance, and atmosphere stability class. It was found that the average odour emission rate from the negative pressure covered earthen manure storage (NAP EMS) was negligible in comparison with the open EMS (0.3 vs 20.3 OU/ s-m2). Downwind odour intensity measured by trained human sniffers on Farm A with covered manure storage was significantly (P<0.05) lower than that on Farm B with open manure storage at 100 and 500 m, but the difference in odour intensity at 1000 m was not significant (P>0.05) between the two farms. A 46% difference in odour emission rate between Farms A and B resulted in a 14% difference in the separation distance for odour annoyance-free between the two farms. When three commonly used dispersion models, namely AUSPLUME, ISCST3, and INPUFF-2, were used to predict downwind odour from the farms, the percentage of agreement between model predictions and field measurements was adequate for downwind distances of 500 and 1000 m, but relatively low for 100 m for all three models. Since the long-distance (>1000 m) predictions are of more practical value, all three models were considered to be adequate in predicting odour downwind from the swine operations. The peak-to-mean ratios of downwind odour intensity were computed from field odour intensity measurements and analysed against averaging time, downwind distance, and atmospheric stability class. The peak-to-mean ratio of field odour intensity increases with averaging time and downwind distance, and unstable atmospheric conditions.","abstract_html":"Odour emissions and instantaneous downwind odour plumes were measured on two 3000-sow swine farrowing farms located in a flat area of southern Manitoba, one farm (Farm A) with open earthen manure storage (EMS) and another (Farm B) with negative air pressure (NAP) covered EMS. Three commonly used dispersion models (ISCST3, AUSPLUME, and INPUFF-2) were used to predict downwind odour distributions on the two farms. Dispersion predictions were based on the measured odour emission data for each farm and on-site weather data recorded by a portable weather station. The peak-to-mean ratios of downwind odour intensity were computed from field odour intensity measurements and analysed against averaging time, downwind distance, and atmosphere stability class. It was found that the average odour emission rate from the negative pressure covered earthen manure storage (NAP EMS) was negligible in comparison with the open EMS (0.3 vs 20.3 OU/ s-m2). Downwind odour intensity measured by trained human sniffers on Farm A with covered manure storage was significantly (P&lt;0.05) lower than that on Farm B with open manure storage at 100 and 500 m, but the difference in odour intensity at 1000 m was not significant (P&gt;0.05) between the two farms. A 46% difference in odour emission rate between Farms A and B resulted in a 14% difference in the separation distance for odour annoyance-free between the two farms. When three commonly used dispersion models, namely AUSPLUME, ISCST3, and INPUFF-2, were used to predict downwind odour from the farms, the percentage of agreement between model predictions and field measurements was adequate for downwind distances of 500 and 1000 m, but relatively low for 100 m for all three models. Since the long-distance (&gt;1000 m) predictions are of more practical value, all three models were considered to be adequate in predicting odour downwind from the swine operations. The peak-to-mean ratios of downwind odour intensity were computed from field odour intensity measurements and analysed against averaging time, downwind distance, and atmospheric stability class. The peak-to-mean ratio of field odour intensity increases with averaging time and downwind distance, and unstable atmospheric conditions.","abstract_has_math":false,"creators":["Zhou, Xiaojing"],"institution":null,"degree_name":null,"degree_level":"Doctor of Philosophy (Ph.D.)","degree_discipline":"Biosystems Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Zhang, Qiang (Biosystems Engineering)"],"committee_chairs":[],"committee_members":["Mann, Danny (Biosystems Engineering)","Gorczyca, Beata (Civil Engineering)","Lemay, Stéphane (The Research and Development Institute for the Agri-Environment (IRDA))"],"year":2011,"date_issued":"2011-01-19T22:34:14Z","date_published":"2011-01-19T22:34:14Z","updated_at":"2026-11-19T09:12:46Z","subjects":["Swine","Odour","Emission","Dispersion"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zhang, Q., X. J. Zhou, N. Cicek, and M. Tenuta. 2007. Measurement of odour and greenhouse gas emissions in two swine farrowing operations. Canadian Biosystems Engineering 49:6.13-6.20.","Guo, H., Y. Li, Q. Zhang, and X. Zhou. 2006. Comparison of four setback models with field odour plume measurement by trained odour sniffers. Canadian Biosystems Engineering 48:6.39-6.48.","Zhou, X, Q. Zhang, and H. Guo. 2005. Measuring odor plumes in two swine farrowing operations. Paper No 054042, Am. Soc. Agric. Eng., St. Joseph, MI. 15 pp.","Zhou, X, Q. Zhang, H. Guo, and Y. Li. 2005. Evaluation of air dispersion models for livestock odour application. Paper No. 05-026. Annual Meeting of CSBE-SCGAB (Can. Soc. Bioengineering). 11 pp.","Zhou, X, Q. Zhang, N. Cicek, and R. York. 2004. Quantification of odor dispersion by human sniffers. Paper No 044197, Am. Soc. Agric. Eng., St. Joseph, MI. 9 pp."],"render_values":[{"text":"Zhang, Q., X. J. Zhou, N. Cicek, and M. Tenuta. 2007. Measurement of odour and greenhouse gas emissions in two swine farrowing operations. Canadian Biosystems Engineering 49:6.13-6.20.","href":null,"code":true},{"text":"Guo, H., Y. Li, Q. Zhang, and X. Zhou. 2006. Comparison of four setback models with field odour plume measurement by trained odour sniffers. Canadian Biosystems Engineering 48:6.39-6.48.","href":null,"code":true},{"text":"Zhou, X, Q. Zhang, and H. Guo. 2005. Measuring odor plumes in two swine farrowing operations. Paper No 054042, Am. Soc. Agric. Eng., St. Joseph, MI. 15 pp.","href":null,"code":true},{"text":"Zhou, X, Q. Zhang, H. Guo, and Y. Li. 2005. Evaluation of air dispersion models for livestock odour application. Paper No. 05-026. Annual Meeting of CSBE-SCGAB (Can. Soc. Bioengineering). 11 pp.","href":null,"code":true},{"text":"Zhou, X, Q. Zhang, N. Cicek, and R. York. 2004. Quantification of odor dispersion by human sniffers. Paper No 044197, Am. Soc. Agric. Eng., St. Joseph, MI. 9 pp.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/4382","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/4382","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F4382","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F4382","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Mann, Danny (Biosystems Engineering)","Gorczyca, Beata (Civil Engineering)","Lemay, Stéphane (The Research and Development Institute for the Agri-Environment (IRDA))"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Zhang, Qiang (Biosystems Engineering)"]},{"key":"dc:creator","label":"Author","values":["Zhou, Xiaojing"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-01-19T22:34:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-01-19T22:34:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-01-19T22:34:14Z"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biosystems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Swine","Odour","Emission","Dispersion"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zhang, Q., X. J. Zhou, N. Cicek, and M. Tenuta. 2007. Measurement of odour and greenhouse gas emissions in two swine farrowing operations. Canadian Biosystems Engineering 49:6.13-6.20.","Guo, H., Y. Li, Q. Zhang, and X. Zhou. 2006. Comparison of four setback models with field odour plume measurement by trained odour sniffers. Canadian Biosystems Engineering 48:6.39-6.48.","Zhou, X, Q. Zhang, and H. Guo. 2005. Measuring odor plumes in two swine farrowing operations. Paper No 054042, Am. Soc. Agric. Eng., St. Joseph, MI. 15 pp.","Zhou, X, Q. Zhang, H. Guo, and Y. Li. 2005. Evaluation of air dispersion models for livestock odour application. Paper No. 05-026. Annual Meeting of CSBE-SCGAB (Can. Soc. Bioengineering). 11 pp.","Zhou, X, Q. Zhang, N. Cicek, and R. York. 2004. Quantification of odor dispersion by human sniffers. Paper No 044197, Am. Soc. Agric. Eng., St. Joseph, MI. 9 pp."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/4382"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Odour emissions and instantaneous downwind odour plumes were measured on two 3000-sow swine farrowing farms located in a flat area of southern Manitoba, one farm (Farm A) with open earthen manure storage (EMS) and another (Farm B) with negative air pressure (NAP) covered EMS. Three commonly used dispersion models (ISCST3, AUSPLUME, and INPUFF-2) were used to predict downwind odour distributions on the two farms. Dispersion predictions were based on the measured odour emission data for each farm and on-site weather data recorded by a portable weather station. The peak-to-mean ratios of downwind odour intensity were computed from field odour intensity measurements and analysed against averaging time, downwind distance, and atmosphere stability class. It was found that the average odour emission rate from the negative pressure covered earthen manure storage (NAP EMS) was negligible in comparison with the open EMS (0.3 vs 20.3 OU/ s-m2). Downwind odour intensity measured by trained human sniffers on Farm A with covered manure storage was significantly (P<0.05) lower than that on Farm B with open manure storage at 100 and 500 m, but the difference in odour intensity at 1000 m was not significant (P>0.05) between the two farms. A 46% difference in odour emission rate between Farms A and B resulted in a 14% difference in the separation distance for odour annoyance-free between the two farms. When three commonly used dispersion models, namely AUSPLUME, ISCST3, and INPUFF-2, were used to predict downwind odour from the farms, the percentage of agreement between model predictions and field measurements was adequate for downwind distances of 500 and 1000 m, but relatively low for 100 m for all three models. Since the long-distance (>1000 m) predictions are of more practical value, all three models were considered to be adequate in predicting odour downwind from the swine operations. The peak-to-mean ratios of downwind odour intensity were computed from field odour intensity measurements and analysed against averaging time, downwind distance, and atmospheric stability class. The peak-to-mean ratio of field odour intensity increases with averaging time and downwind distance, and unstable atmospheric conditions."]},{"key":"dc:description.note","label":"Dc Description Note","values":["February 2011"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["3208914 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Emission and dispersion of odour from swine operations"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Mann, Danny (Biosystems Engineering)","Gorczyca, Beata (Civil Engineering)","Lemay, Stéphane (The Research and Development Institute for the Agri-Environment (IRDA))"],"dc:contributor.supervisor":["Zhang, Qiang (Biosystems Engineering)"],"dc:creator":["Zhou, Xiaojing"],"dc:date.accessioned":["2011-01-19T22:34:14Z"],"dc:date.available":["2011-01-19T22:34:14Z"],"dc:date.issued":["2011-01-19T22:34:14Z"],"dc:description.abstract":["Odour emissions and instantaneous downwind odour plumes were measured on two 3000-sow swine farrowing farms located in a flat area of southern Manitoba, one farm (Farm A) with open earthen manure storage (EMS) and another (Farm B) with negative air pressure (NAP) covered EMS. Three commonly used dispersion models (ISCST3, AUSPLUME, and INPUFF-2) were used to predict downwind odour distributions on the two farms. Dispersion predictions were based on the measured odour emission data for each farm and on-site weather data recorded by a portable weather station. The peak-to-mean ratios of downwind odour intensity were computed from field odour intensity measurements and analysed against averaging time, downwind distance, and atmosphere stability class. It was found that the average odour emission rate from the negative pressure covered earthen manure storage (NAP EMS) was negligible in comparison with the open EMS (0.3 vs 20.3 OU/ s-m2). Downwind odour intensity measured by trained human sniffers on Farm A with covered manure storage was significantly (P<0.05) lower than that on Farm B with open manure storage at 100 and 500 m, but the difference in odour intensity at 1000 m was not significant (P>0.05) between the two farms. A 46% difference in odour emission rate between Farms A and B resulted in a 14% difference in the separation distance for odour annoyance-free between the two farms. When three commonly used dispersion models, namely AUSPLUME, ISCST3, and INPUFF-2, were used to predict downwind odour from the farms, the percentage of agreement between model predictions and field measurements was adequate for downwind distances of 500 and 1000 m, but relatively low for 100 m for all three models. Since the long-distance (>1000 m) predictions are of more practical value, all three models were considered to be adequate in predicting odour downwind from the swine operations. The peak-to-mean ratios of downwind odour intensity were computed from field odour intensity measurements and analysed against averaging time, downwind distance, and atmospheric stability class. The peak-to-mean ratio of field odour intensity increases with averaging time and downwind distance, and unstable atmospheric conditions."],"dc:description.note":["February 2011"],"dc:format.extent":["3208914 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.citation":["Zhang, Q., X. J. Zhou, N. Cicek, and M. Tenuta. 2007. Measurement of odour and greenhouse gas emissions in two swine farrowing operations. Canadian Biosystems Engineering 49:6.13-6.20.","Guo, H., Y. Li, Q. Zhang, and X. Zhou. 2006. Comparison of four setback models with field odour plume measurement by trained odour sniffers. Canadian Biosystems Engineering 48:6.39-6.48.","Zhou, X, Q. Zhang, and H. Guo. 2005. Measuring odor plumes in two swine farrowing operations. Paper No 054042, Am. Soc. Agric. Eng., St. Joseph, MI. 15 pp.","Zhou, X, Q. Zhang, H. Guo, and Y. Li. 2005. Evaluation of air dispersion models for livestock odour application. Paper No. 05-026. Annual Meeting of CSBE-SCGAB (Can. Soc. Bioengineering). 11 pp.","Zhou, X, Q. Zhang, N. Cicek, and R. York. 2004. Quantification of odor dispersion by human sniffers. Paper No 044197, Am. Soc. Agric. Eng., St. Joseph, MI. 9 pp."],"dc:identifier.uri":["http://hdl.handle.net/1993/4382"],"dc:language.iso":["eng"],"dc:subject":["Swine","Odour","Emission","Dispersion"],"dc:title":["Emission and dispersion of odour from swine operations"],"dc:type":["doctoral thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biosystems Engineering"],"thesis:degree_level":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T09:12:46Z"}