{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/4902"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/4902","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Experimental study on passive dynamic bipedal walking: effects of parameter changes on gait patterns","abstract":"Passive dynamic walking is a gait developed, partially or in whole, by the energy provided by gravity. Research on passive dynamic bipedal walking helps develop an understanding of bipedal walking mechanics. Moreover, experimental passive dynamic research provides a base to compare and validate simulation results. An improved kneed bipedal walking mechanism and an improved measurement system are used to study the passive gait patterns. Gait measurements are conducted on the treadmill to evaluate the effects of the treadmill angle of inclination, mass distribution of the biped, treadmill belt speed, length of flat feet and thigh-shank length on the gait patterns. Most of these dynamic and geometric parameters have significant effects on step length, step period and robustness of the passive gait. Difficulties have been faced with the study of the flat feet and the leg length variation. Suggestions have been provided for future work. Experimental results are compared with previous work based on both the experimental and the computer simulation.","abstract_html":"Passive dynamic walking is a gait developed, partially or in whole, by the energy provided by gravity. Research on passive dynamic bipedal walking helps develop an understanding of bipedal walking mechanics. Moreover, experimental passive dynamic research provides a base to compare and validate simulation results. An improved kneed bipedal walking mechanism and an improved measurement system are used to study the passive gait patterns. Gait measurements are conducted on the treadmill to evaluate the effects of the treadmill angle of inclination, mass distribution of the biped, treadmill belt speed, length of flat feet and thigh-shank length on the gait patterns. Most of these dynamic and geometric parameters have significant effects on step length, step period and robustness of the passive gait. Difficulties have been faced with the study of the flat feet and the leg length variation. Suggestions have been provided for future work. Experimental results are compared with previous work based on both the experimental and the computer simulation.","abstract_has_math":false,"creators":["Rushdi, Kazi"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Mechanical and Manufacturing Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Wu, Christine Qiong (Mechanical and Manufacturing Engineering)"],"committee_chairs":[],"committee_members":["Luo, Yunhua (Mechanical and Manufacturing Engineering)","Filizadeh, Shaahin (Electrical and Computer Engineering)"],"year":2011,"date_issued":"2011-09-13","date_published":"2011-09-13","updated_at":"2026-11-19T09:04:19Z","subjects":["Passive","Biped","Experimental","Gait"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/4902","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/4902","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F4902","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F4902","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Luo, Yunhua (Mechanical and Manufacturing Engineering)","Filizadeh, Shaahin (Electrical and Computer Engineering)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Wu, Christine Qiong (Mechanical and Manufacturing Engineering)"]},{"key":"dc:creator","label":"Author","values":["Rushdi, Kazi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-09-13T16:37:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-09-13T16:37:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-09-13"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Manufacturing Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Passive","Biped","Experimental","Gait"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/4902"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Passive dynamic walking is a gait developed, partially or in whole, by the energy provided by gravity. Research on passive dynamic bipedal walking helps develop an understanding of bipedal walking mechanics. Moreover, experimental passive dynamic research provides a base to compare and validate simulation results. An improved kneed bipedal walking mechanism and an improved measurement system are used to study the passive gait patterns. Gait measurements are conducted on the treadmill to evaluate the effects of the treadmill angle of inclination, mass distribution of the biped, treadmill belt speed, length of flat feet and thigh-shank length on the gait patterns. Most of these dynamic and geometric parameters have significant effects on step length, step period and robustness of the passive gait. Difficulties have been faced with the study of the flat feet and the leg length variation. Suggestions have been provided for future work. Experimental results are compared with previous work based on both the experimental and the computer simulation."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2011"]},{"key":"dc:title","label":"Title","values":["Experimental study on passive dynamic bipedal walking: effects of parameter changes on gait patterns"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Luo, Yunhua (Mechanical and Manufacturing Engineering)","Filizadeh, Shaahin (Electrical and Computer Engineering)"],"dc:contributor.supervisor":["Wu, Christine Qiong (Mechanical and Manufacturing Engineering)"],"dc:creator":["Rushdi, Kazi"],"dc:date.accessioned":["2011-09-13T16:37:25Z"],"dc:date.available":["2011-09-13T16:37:25Z"],"dc:date.issued":["2011-09-13"],"dc:description.abstract":["Passive dynamic walking is a gait developed, partially or in whole, by the energy provided by gravity. Research on passive dynamic bipedal walking helps develop an understanding of bipedal walking mechanics. Moreover, experimental passive dynamic research provides a base to compare and validate simulation results. An improved kneed bipedal walking mechanism and an improved measurement system are used to study the passive gait patterns. Gait measurements are conducted on the treadmill to evaluate the effects of the treadmill angle of inclination, mass distribution of the biped, treadmill belt speed, length of flat feet and thigh-shank length on the gait patterns. Most of these dynamic and geometric parameters have significant effects on step length, step period and robustness of the passive gait. Difficulties have been faced with the study of the flat feet and the leg length variation. Suggestions have been provided for future work. Experimental results are compared with previous work based on both the experimental and the computer simulation."],"dc:description.note":["October 2011"],"dc:identifier.uri":["http://hdl.handle.net/1993/4902"],"dc:language.iso":["eng"],"dc:subject":["Passive","Biped","Experimental","Gait"],"dc:title":["Experimental study on passive dynamic bipedal walking: effects of parameter changes on gait patterns"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical and Manufacturing Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:04:19Z"}