{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/4940"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/4940","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Effect of high frequency TENS on cold hyperalgesia induced by topical menthol in healthy subjects","abstract":"The primary aim of this study was to determine the effect of high frequency Transcutaneous Electrical Nerve Stimulation (TENS) on cold sensory function following topical application of menthol. Quantitative sensory testing was used to determine cold sensation and cold pain thresholds before and after topical application of a 40% menthol solution in 9 male and 11 female subjects. In a separate session the effect of TENS (100 HZ, constant pulse, 100µs, 20 minutes) was determined on menthol-induced cold sensation. Menthol produced a distinct cold hyperalgesia which was significantly reduced during the application of high frequency TENS. The analgesic effect of TENS persisted beyond the application period for at least 20 minutes. Menthol also reduced cold detection thresholds but TENS had no effect on this aspect of cold sensation. These data support the use of TENS as a means of treating cold hyperalgesia such as that found in neuropathic pain states.","abstract_html":"The primary aim of this study was to determine the effect of high frequency Transcutaneous Electrical Nerve Stimulation (TENS) on cold sensory function following topical application of menthol. Quantitative sensory testing was used to determine cold sensation and cold pain thresholds before and after topical application of a 40% menthol solution in 9 male and 11 female subjects. In a separate session the effect of TENS (100 HZ, constant pulse, 100µs, 20 minutes) was determined on menthol-induced cold sensation. Menthol produced a distinct cold hyperalgesia which was significantly reduced during the application of high frequency TENS. The analgesic effect of TENS persisted beyond the application period for at least 20 minutes. Menthol also reduced cold detection thresholds but TENS had no effect on this aspect of cold sensation. These data support the use of TENS as a means of treating cold hyperalgesia such as that found in neuropathic pain states.","abstract_has_math":false,"creators":["Iribarren, Onae"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Medical Rehabilitation","degree_department":null,"school":null,"contributors":[],"advisors":["MacNeil, Brian (Physical Therapy)"],"committee_chairs":[],"committee_members":["MacNeil, Brian (Physical Therapy)","Shay, Barbara (Physical Therapy)","Shefchyk, Susan (Physiology)"],"year":2011,"date_issued":"2011-09-27","date_published":"2011-09-27","updated_at":"2026-11-19T09:12:25Z","subjects":["TENS","Menthol","QST","Cold hyperalgesia"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/4940","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/4940","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F4940","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F4940","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["MacNeil, Brian (Physical Therapy)","Shay, Barbara (Physical Therapy)","Shefchyk, Susan (Physiology)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["MacNeil, Brian (Physical Therapy)"]},{"key":"dc:creator","label":"Author","values":["Iribarren, Onae"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-09-27T15:24:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-09-27T15:24:28Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-09-27"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medical Rehabilitation"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TENS","Menthol","QST","Cold hyperalgesia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/4940"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The primary aim of this study was to determine the effect of high frequency Transcutaneous Electrical Nerve Stimulation (TENS) on cold sensory function following topical application of menthol. Quantitative sensory testing was used to determine cold sensation and cold pain thresholds before and after topical application of a 40% menthol solution in 9 male and 11 female subjects. In a separate session the effect of TENS (100 HZ, constant pulse, 100µs, 20 minutes) was determined on menthol-induced cold sensation. Menthol produced a distinct cold hyperalgesia which was significantly reduced during the application of high frequency TENS. The analgesic effect of TENS persisted beyond the application period for at least 20 minutes. Menthol also reduced cold detection thresholds but TENS had no effect on this aspect of cold sensation. These data support the use of TENS as a means of treating cold hyperalgesia such as that found in neuropathic pain states."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2011"]},{"key":"dc:title","label":"Title","values":["Effect of high frequency TENS on cold hyperalgesia induced by topical menthol in healthy subjects"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["MacNeil, Brian (Physical Therapy)","Shay, Barbara (Physical Therapy)","Shefchyk, Susan (Physiology)"],"dc:contributor.supervisor":["MacNeil, Brian (Physical Therapy)"],"dc:creator":["Iribarren, Onae"],"dc:date.accessioned":["2011-09-27T15:24:28Z"],"dc:date.available":["2011-09-27T15:24:28Z"],"dc:date.issued":["2011-09-27"],"dc:description.abstract":["The primary aim of this study was to determine the effect of high frequency Transcutaneous Electrical Nerve Stimulation (TENS) on cold sensory function following topical application of menthol. Quantitative sensory testing was used to determine cold sensation and cold pain thresholds before and after topical application of a 40% menthol solution in 9 male and 11 female subjects. In a separate session the effect of TENS (100 HZ, constant pulse, 100µs, 20 minutes) was determined on menthol-induced cold sensation. Menthol produced a distinct cold hyperalgesia which was significantly reduced during the application of high frequency TENS. The analgesic effect of TENS persisted beyond the application period for at least 20 minutes. Menthol also reduced cold detection thresholds but TENS had no effect on this aspect of cold sensation. These data support the use of TENS as a means of treating cold hyperalgesia such as that found in neuropathic pain states."],"dc:description.note":["October 2011"],"dc:identifier.uri":["http://hdl.handle.net/1993/4940"],"dc:language.iso":["eng"],"dc:subject":["TENS","Menthol","QST","Cold hyperalgesia"],"dc:title":["Effect of high frequency TENS on cold hyperalgesia induced by topical menthol in healthy subjects"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Medical Rehabilitation"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:12:25Z"}