{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/5116"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/5116","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Understanding effect and diagnosis of internal leakage in hydrostatic actuation systems","abstract":"This research presents implementation of the Wavelet transform for detecting internal leakages occurring within an Electro-Hydrostatic Actuation (EHA) system. Simulation studies are carried out in order to investigate the feasibility of a particular approach and to determine the level of accuracy that can be expected in the experimental system. The effect of friction, orifices and the dynamics of motor/pump are considered during the simulation study. Experimental analysis based on Wavelet transform is conducted for detecting internal leakage. The original pressure signals at either side of the cylinder are decomposed using Wavelet transform to detect internal leakage which is clearly identified. Results obtained through the use of Wavelet transform prove that this method is fast and easily-implementable for leakage detection in EHA on the basis of the pressure data obtained. Internal leakages as low as 0.0042 lit/min are shown to be detectable 85% of the time using a structured input signal.","abstract_html":"This research presents implementation of the Wavelet transform for detecting internal leakages occurring within an Electro-Hydrostatic Actuation (EHA) system. Simulation studies are carried out in order to investigate the feasibility of a particular approach and to determine the level of accuracy that can be expected in the experimental system. The effect of friction, orifices and the dynamics of motor/pump are considered during the simulation study. Experimental analysis based on Wavelet transform is conducted for detecting internal leakage. The original pressure signals at either side of the cylinder are decomposed using Wavelet transform to detect internal leakage which is clearly identified. Results obtained through the use of Wavelet transform prove that this method is fast and easily-implementable for leakage detection in EHA on the basis of the pressure data obtained. Internal leakages as low as 0.0042 lit/min are shown to be detectable 85% of the time using a structured input signal.","abstract_has_math":false,"creators":["Thakur, Amit"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Mechanical and Manufacturing Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Sepehri,Nariman (Mechanical & Manufacturing)"],"committee_chairs":[],"committee_members":["Balakrishnan, Subramaniam (Mechanical and Manufacturing Engineering)","Fung, Wai-Keung (Electrical & Computer)"],"year":2012,"date_issued":"2012-01-27","date_published":"2012-01-27","updated_at":"2026-11-19T09:06:30Z","subjects":["Electrohydrostatic","EHA"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/5116","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/5116","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F5116","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F5116","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Balakrishnan, Subramaniam (Mechanical and Manufacturing Engineering)","Fung, Wai-Keung (Electrical & Computer)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Sepehri,Nariman (Mechanical & Manufacturing)"]},{"key":"dc:creator","label":"Author","values":["Thakur, Amit"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-01-27T16:39:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-01-27T16:39:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-01-27"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Manufacturing Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrohydrostatic","EHA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/5116"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research presents implementation of the Wavelet transform for detecting internal leakages occurring within an Electro-Hydrostatic Actuation (EHA) system. Simulation studies are carried out in order to investigate the feasibility of a particular approach and to determine the level of accuracy that can be expected in the experimental system. The effect of friction, orifices and the dynamics of motor/pump are considered during the simulation study. Experimental analysis based on Wavelet transform is conducted for detecting internal leakage. The original pressure signals at either side of the cylinder are decomposed using Wavelet transform to detect internal leakage which is clearly identified. Results obtained through the use of Wavelet transform prove that this method is fast and easily-implementable for leakage detection in EHA on the basis of the pressure data obtained. Internal leakages as low as 0.0042 lit/min are shown to be detectable 85% of the time using a structured input signal."]},{"key":"dc:description.note","label":"Dc Description Note","values":["May 2012"]},{"key":"dc:title","label":"Title","values":["Understanding effect and diagnosis of internal leakage in hydrostatic actuation systems"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Balakrishnan, Subramaniam (Mechanical and Manufacturing Engineering)","Fung, Wai-Keung (Electrical & Computer)"],"dc:contributor.supervisor":["Sepehri,Nariman (Mechanical & Manufacturing)"],"dc:creator":["Thakur, Amit"],"dc:date.accessioned":["2012-01-27T16:39:38Z"],"dc:date.available":["2012-01-27T16:39:38Z"],"dc:date.issued":["2012-01-27"],"dc:description.abstract":["This research presents implementation of the Wavelet transform for detecting internal leakages occurring within an Electro-Hydrostatic Actuation (EHA) system. Simulation studies are carried out in order to investigate the feasibility of a particular approach and to determine the level of accuracy that can be expected in the experimental system. The effect of friction, orifices and the dynamics of motor/pump are considered during the simulation study. Experimental analysis based on Wavelet transform is conducted for detecting internal leakage. The original pressure signals at either side of the cylinder are decomposed using Wavelet transform to detect internal leakage which is clearly identified. Results obtained through the use of Wavelet transform prove that this method is fast and easily-implementable for leakage detection in EHA on the basis of the pressure data obtained. Internal leakages as low as 0.0042 lit/min are shown to be detectable 85% of the time using a structured input signal."],"dc:description.note":["May 2012"],"dc:identifier.uri":["http://hdl.handle.net/1993/5116"],"dc:language.iso":["eng"],"dc:subject":["Electrohydrostatic","EHA"],"dc:title":["Understanding effect and diagnosis of internal leakage in hydrostatic actuation systems"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical and Manufacturing Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:06:30Z"}