{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/8477"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/8477","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Surface-engineering of Poly(ethylene terephthalate) for improved haemocompatibility","abstract":"Cardiovascular diseases (CVD) remain the number one cause of mortality globally. Compared with autologous vessels, synthetic vascular grafts such as poly (ethylene terephthalate) (PET) vascular grafts are still widely used to replace or bypass diseased arteries. However, PET is susceptible to thrombosis when in contact with blood. In this study, “bioactive”/“bioinert” agents – heparin and poly(ethylene glycol) (PEG) were immobilized covalently on chemically inert PET substrate using a special surface modification technique – surface interpenetrating network (IPN) successfully. The improved haemocompatibility of heparin modified PET surface was proved by a platelet adhesion assay. The PEG modified PET substrate also demonstrated decreased platelet adhesion. Further research has been conducted to immobilize aliphatic chains ended with sulfate and carboxylate groups (existing in heparin) on a model substrate. In vitro thrombus formation test indicated an interesting anticoagulating action between those anionic groups with an optimal ratio in the range of (3:1) and (4.5:1).","abstract_html":"Cardiovascular diseases (CVD) remain the number one cause of mortality globally. Compared with autologous vessels, synthetic vascular grafts such as poly (ethylene terephthalate) (PET) vascular grafts are still widely used to replace or bypass diseased arteries. However, PET is susceptible to thrombosis when in contact with blood. In this study, “bioactive”/“bioinert” agents – heparin and poly(ethylene glycol) (PEG) were immobilized covalently on chemically inert PET substrate using a special surface modification technique – surface interpenetrating network (IPN) successfully. The improved haemocompatibility of heparin modified PET surface was proved by a platelet adhesion assay. The PEG modified PET substrate also demonstrated decreased platelet adhesion. Further research has been conducted to immobilize aliphatic chains ended with sulfate and carboxylate groups (existing in heparin) on a model substrate. In vitro thrombus formation test indicated an interesting anticoagulating action between those anionic groups with an optimal ratio in the range of (3:1) and (4.5:1).","abstract_has_math":false,"creators":["Li, Jiang"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Textile Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Liu, Song (Textile Sciences)"],"committee_chairs":[],"committee_members":["Harding, Gregory (Surgery)","King, Martin (Textile Sciences)"],"year":2012,"date_issued":"2012-08-24","date_published":"2012-08-24","updated_at":"2026-11-19T09:06:30Z","subjects":["PET","Interpenetrating networks","Haemocompatibility"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/8477","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/8477","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F8477","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F8477","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Harding, Gregory (Surgery)","King, Martin (Textile Sciences)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Liu, Song (Textile Sciences)"]},{"key":"dc:creator","label":"Author","values":["Li, Jiang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-24T20:21:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-24T20:21:01Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-08-24"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Textile Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["PET","Interpenetrating networks","Haemocompatibility"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/8477"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cardiovascular diseases (CVD) remain the number one cause of mortality globally. Compared with autologous vessels, synthetic vascular grafts such as poly (ethylene terephthalate) (PET) vascular grafts are still widely used to replace or bypass diseased arteries. However, PET is susceptible to thrombosis when in contact with blood. In this study, “bioactive”/“bioinert” agents – heparin and poly(ethylene glycol) (PEG) were immobilized covalently on chemically inert PET substrate using a special surface modification technique – surface interpenetrating network (IPN) successfully. The improved haemocompatibility of heparin modified PET surface was proved by a platelet adhesion assay. The PEG modified PET substrate also demonstrated decreased platelet adhesion. Further research has been conducted to immobilize aliphatic chains ended with sulfate and carboxylate groups (existing in heparin) on a model substrate. In vitro thrombus formation test indicated an interesting anticoagulating action between those anionic groups with an optimal ratio in the range of (3:1) and (4.5:1)."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2012"]},{"key":"dc:title","label":"Title","values":["Surface-engineering of Poly(ethylene terephthalate) for improved haemocompatibility"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Harding, Gregory (Surgery)","King, Martin (Textile Sciences)"],"dc:contributor.supervisor":["Liu, Song (Textile Sciences)"],"dc:creator":["Li, Jiang"],"dc:date.accessioned":["2012-08-24T20:21:01Z"],"dc:date.available":["2012-08-24T20:21:01Z"],"dc:date.issued":["2012-08-24"],"dc:description.abstract":["Cardiovascular diseases (CVD) remain the number one cause of mortality globally. Compared with autologous vessels, synthetic vascular grafts such as poly (ethylene terephthalate) (PET) vascular grafts are still widely used to replace or bypass diseased arteries. However, PET is susceptible to thrombosis when in contact with blood. In this study, “bioactive”/“bioinert” agents – heparin and poly(ethylene glycol) (PEG) were immobilized covalently on chemically inert PET substrate using a special surface modification technique – surface interpenetrating network (IPN) successfully. The improved haemocompatibility of heparin modified PET surface was proved by a platelet adhesion assay. The PEG modified PET substrate also demonstrated decreased platelet adhesion. Further research has been conducted to immobilize aliphatic chains ended with sulfate and carboxylate groups (existing in heparin) on a model substrate. In vitro thrombus formation test indicated an interesting anticoagulating action between those anionic groups with an optimal ratio in the range of (3:1) and (4.5:1)."],"dc:description.note":["October 2012"],"dc:identifier.uri":["http://hdl.handle.net/1993/8477"],"dc:language.iso":["eng"],"dc:subject":["PET","Interpenetrating networks","Haemocompatibility"],"dc:title":["Surface-engineering of Poly(ethylene terephthalate) for improved haemocompatibility"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Textile Sciences"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:06:30Z"}