{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/8864"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/8864","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"A novel method to increase depth of imaging in optical coherence tomography using ultrasound","abstract":"Optical coherence tomography (OCT) is a biomedical imaging technique with many current applications. A limitation of the technique is its shallow depth of imaging. A major factor limiting imaging depth in OCT is multiple-scattering of light. This thesis proposes an integrated computational imgaging approach to improve depth of imaging in OCT. In this approach ultrasound patterns are used to modulate the refractive index of tissue. Simulations of the impact of ultrasound on the refractive index are performed, and the results are shown in this thesis. Simulations of the impact of the modulated refractive index on the propagation of light in tissue are needed. But there is no suitable simulator available. Thus, we implemented a Monte Carlo method to solve integral equations that could be used to perform these simulations. Results for integral equations in 1-D and 2-D are shown.","abstract_html":"Optical coherence tomography (OCT) is a biomedical imaging technique with many current applications. A limitation of the technique is its shallow depth of imaging. A major factor limiting imaging depth in OCT is multiple-scattering of light. This thesis proposes an integrated computational imgaging approach to improve depth of imaging in OCT. In this approach ultrasound patterns are used to modulate the refractive index of tissue. Simulations of the impact of ultrasound on the refractive index are performed, and the results are shown in this thesis. Simulations of the impact of the modulated refractive index on the propagation of light in tissue are needed. But there is no suitable simulator available. Thus, we implemented a Monte Carlo method to solve integral equations that could be used to perform these simulations. Results for integral equations in 1-D and 2-D are shown.","abstract_has_math":false,"creators":["Pereira Bogado, Pedro Fernando"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Sherif, Sherif (Electrical and Computer Engineering)"],"committee_chairs":[],"committee_members":["Shafai, Cyrus (Electrical and Computer Engineering)","Pistorius, Stephen (Physics and Astronomy)"],"year":2012,"date_issued":"2012-09-18","date_published":"2012-09-18","updated_at":"2026-11-19T09:06:07Z","subjects":["Integrated Computational Imaging","Monte Carlo methods","Integral equations"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/8864","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/8864","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F8864","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F8864","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Shafai, Cyrus (Electrical and Computer Engineering)","Pistorius, Stephen (Physics and Astronomy)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Sherif, Sherif (Electrical and Computer Engineering)"]},{"key":"dc:creator","label":"Author","values":["Pereira Bogado, Pedro Fernando"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-09-18T14:54:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-09-18T14:54:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-09-18"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Integrated Computational Imaging","Monte Carlo methods","Integral equations"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/8864"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Optical coherence tomography (OCT) is a biomedical imaging technique with many current applications. A limitation of the technique is its shallow depth of imaging. A major factor limiting imaging depth in OCT is multiple-scattering of light. This thesis proposes an integrated computational imgaging approach to improve depth of imaging in OCT. In this approach ultrasound patterns are used to modulate the refractive index of tissue. Simulations of the impact of ultrasound on the refractive index are performed, and the results are shown in this thesis. Simulations of the impact of the modulated refractive index on the propagation of light in tissue are needed. But there is no suitable simulator available. Thus, we implemented a Monte Carlo method to solve integral equations that could be used to perform these simulations. Results for integral equations in 1-D and 2-D are shown."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2012"]},{"key":"dc:title","label":"Title","values":["A novel method to increase depth of imaging in optical coherence tomography using ultrasound"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Shafai, Cyrus (Electrical and Computer Engineering)","Pistorius, Stephen (Physics and Astronomy)"],"dc:contributor.supervisor":["Sherif, Sherif (Electrical and Computer Engineering)"],"dc:creator":["Pereira Bogado, Pedro Fernando"],"dc:date.accessioned":["2012-09-18T14:54:49Z"],"dc:date.available":["2012-09-18T14:54:49Z"],"dc:date.issued":["2012-09-18"],"dc:description.abstract":["Optical coherence tomography (OCT) is a biomedical imaging technique with many current applications. A limitation of the technique is its shallow depth of imaging. A major factor limiting imaging depth in OCT is multiple-scattering of light. This thesis proposes an integrated computational imgaging approach to improve depth of imaging in OCT. In this approach ultrasound patterns are used to modulate the refractive index of tissue. Simulations of the impact of ultrasound on the refractive index are performed, and the results are shown in this thesis. Simulations of the impact of the modulated refractive index on the propagation of light in tissue are needed. But there is no suitable simulator available. Thus, we implemented a Monte Carlo method to solve integral equations that could be used to perform these simulations. Results for integral equations in 1-D and 2-D are shown."],"dc:description.note":["October 2012"],"dc:identifier.uri":["http://hdl.handle.net/1993/8864"],"dc:language.iso":["eng"],"dc:subject":["Integrated Computational Imaging","Monte Carlo methods","Integral equations"],"dc:title":["A novel method to increase depth of imaging in optical coherence tomography using ultrasound"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:06:07Z"}